ABAP Select data from SAP table HCMT_BSP_PA_DE_R0700_DBBG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_DE_R0700_DBBG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_DE_R0700_DBBG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_DE_R0700_DBBG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_DE_R0700_DBBG TYPE STANDARD TABLE OF HCMT_BSP_PA_DE_R0700_DBBG,
      WA_HCMT_BSP_PA_DE_R0700_DBBG TYPE HCMT_BSP_PA_DE_R0700_DBBG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_DE_R0700_DBBG> TYPE HCMT_BSP_PA_DE_R0700_DBBG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_DE_R0700_DBBG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_DE_R0700_DBBG
  INTO TABLE IT_HCMT_BSP_PA_DE_R0700_DBBG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_DE_R0700_DBBG
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_DE_R0700_DBBG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_DE_R0700_DBBG INDEX 1 INTO DATA(WA_HCMT_BSP_PA_DE_R0700_DBBG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_DE_R0700_DBBG ASSIGNING <HCMT_BSP_PA_DE_R0700_DBBG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_DE_R0700_DBBG>-D_GAEGKV = 1.
<HCMT_BSP_PA_DE_R0700_DBBG>-D_M_GAEGKV = 1.
<HCMT_BSP_PA_DE_R0700_DBBG>-SW_GAEGKV = 1.
<HCMT_BSP_PA_DE_R0700_DBBG>-D_GAEGRV = 1.
<HCMT_BSP_PA_DE_R0700_DBBG>-D_M_GAEGRV = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_DE_R0700_DBBG INTO WA_HCMT_BSP_PA_DE_R0700_DBBG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_DE_R0700_DBBG-SW_GAEGRV, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBBG-D_GAEGAV, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBBG-D_M_GAEGAV, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBBG-SW_GAEGAV, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBBG-KENNZKVL, sy-vline,
WA_HCMT_BSP_PA_DE_R0700_DBBG-M_KENNZKVL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_DE_R0700_DBBG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_DE_R0700_DBBG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_DE_R0700_DBBG INTO WA_HCMT_BSP_PA_DE_R0700_DBBG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_DE_R0700_DBBG_STR,
D_GAEGKV TYPE STRING,
D_M_GAEGKV TYPE STRING,
SW_GAEGKV TYPE STRING,
D_GAEGRV TYPE STRING,
D_M_GAEGRV TYPE STRING,
SW_GAEGRV TYPE STRING,
D_GAEGAV TYPE STRING,
D_M_GAEGAV TYPE STRING,
SW_GAEGAV TYPE STRING,
KENNZKVL TYPE STRING,
M_KENNZKVL TYPE STRING,
KENNZRVL TYPE STRING,
M_KENNZRVL TYPE STRING,
KENNZAVL TYPE STRING,
M_KENNZAVL TYPE STRING,
D_EGAKV TYPE STRING,
D_M_EGAKV TYPE STRING,
SW_EGAKV TYPE STRING,
D_EGARV TYPE STRING,
D_M_EGARV TYPE STRING,
SW_EGARV TYPE STRING,
D_EGAAV TYPE STRING,
D_M_EGAAV TYPE STRING,
SW_EGAAV TYPE STRING,
KENNZKVE TYPE STRING,
M_KENNZKVE TYPE STRING,
KENNZRVE TYPE STRING,
M_KENNZRVE TYPE STRING,
KENNZAVE TYPE STRING,
M_KENNZAVE TYPE STRING,
KENNZRK TYPE STRING,
M_KENNZRK TYPE STRING,
SVTG TYPE STRING,
M_SVTG TYPE STRING,
SW_SVTG TYPE STRING,
D_O_LFDEGKV TYPE STRING,
D_M_O_LFDEGKV TYPE STRING,
SW_O_LFDEGKV TYPE STRING,
D_O_LFDEGRV TYPE STRING,
D_M_O_LFDEGRV TYPE STRING,
SW_O_LFDEGRV TYPE STRING,
D_O_LFDEGAV TYPE STRING,
D_M_O_LFDEGAV TYPE STRING,
SW_O_LFDEGAV TYPE STRING,
D_O_EZEG TYPE STRING,
D_M_O_EZEG TYPE STRING,
SW_O_EZEG TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_DE_R0700_DBBG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_GAEGKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_GAEGKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_GAEGKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_GAEGRV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_GAEGRV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_GAEGRV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_GAEGAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_GAEGAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_GAEGAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-KENNZKVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_KENNZKVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-KENNZRVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_KENNZRVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-KENNZAVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_KENNZAVL sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_EGAKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_EGAKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_EGAKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_EGARV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_EGARV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_EGARV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_EGAAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_EGAAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_EGAAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-KENNZKVE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_KENNZKVE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-KENNZRVE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_KENNZRVE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-KENNZAVE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_KENNZAVE sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-KENNZRK sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_KENNZRK sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SVTG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-M_SVTG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_SVTG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_O_LFDEGKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_O_LFDEGKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_O_LFDEGKV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_O_LFDEGRV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_O_LFDEGRV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_O_LFDEGRV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_O_LFDEGAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_O_LFDEGAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_O_LFDEGAV sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_O_EZEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-D_M_O_EZEG sy-vline
WA_HCMT_BSP_PA_DE_R0700_DBBG_STR-SW_O_EZEG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.