ABAP Select data from SAP table HCMT_BSP_PA_DE_R0652 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_DE_R0652 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_DE_R0652. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_DE_R0652 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_DE_R0652 TYPE STANDARD TABLE OF HCMT_BSP_PA_DE_R0652,
      WA_HCMT_BSP_PA_DE_R0652 TYPE HCMT_BSP_PA_DE_R0652,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_DE_R0652> TYPE HCMT_BSP_PA_DE_R0652.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_DE_R0652.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_DE_R0652
  INTO TABLE IT_HCMT_BSP_PA_DE_R0652.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_DE_R0652
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_DE_R06522).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_DE_R0652 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_DE_R06522).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_DE_R0652 ASSIGNING <HCMT_BSP_PA_DE_R0652>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_DE_R0652>-OBJECT_KEY = 1.
<HCMT_BSP_PA_DE_R0652>-PERNR = 1.
<HCMT_BSP_PA_DE_R0652>-AEDTM = 1.
<HCMT_BSP_PA_DE_R0652>-UNAME = 1.
<HCMT_BSP_PA_DE_R0652>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_DE_R0652 INTO WA_HCMT_BSP_PA_DE_R0652.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_DE_R0652-SPRTX, sy-vline,
WA_HCMT_BSP_PA_DE_R0652-ITBLD, sy-vline,
WA_HCMT_BSP_PA_DE_R0652-ITXEX, sy-vline,
WA_HCMT_BSP_PA_DE_R0652-BEGDA, sy-vline,
WA_HCMT_BSP_PA_DE_R0652-ENDDA, sy-vline,
WA_HCMT_BSP_PA_DE_R0652-WAERS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_DE_R0652 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_DE_R0652 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_DE_R0652 INTO WA_HCMT_BSP_PA_DE_R0652. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_DE_R0652_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
WAERS TYPE STRING,
KGBVN TYPE STRING,
KGBNN TYPE STRING,
KIGNR TYPE STRING,
BEKNZ TYPE STRING,
ABDAU TYPE STRING,
AVDAT TYPE STRING,
AVEIN TYPE STRING,
AVEIB TYPE STRING,
AVEWO TYPE STRING,
REGNR TYPE STRING,
ABPRF TYPE STRING,
APDAT TYPE STRING,
SUERG TYPE STRING,
VLAVH TYPE STRING,
AVEND TYPE STRING,
UNAAV TYPE STRING,
AVBEG TYPE STRING,
TLZEI TYPE STRING,
ARTNL TYPE STRING,
NDAT1 TYPE STRING,
NDAT2 TYPE STRING,
NDAT3 TYPE STRING,
NDAT4 TYPE STRING,
NBET1 TYPE STRING,
NBET2 TYPE STRING,
NBET3 TYPE STRING,
NBET4 TYPE STRING,
NDAT5 TYPE STRING,
NDAT6 TYPE STRING,
NDAT7 TYPE STRING,
NDAT8 TYPE STRING,
NBET5 TYPE STRING,
NBET6 TYPE STRING,
NBET7 TYPE STRING,
NBET8 TYPE STRING,
PAULO TYPE STRING,
ARTLE TYPE STRING,
PDAT1 TYPE STRING,
PBET1 TYPE STRING,
PDAT2 TYPE STRING,
PBET2 TYPE STRING,
PDAT3 TYPE STRING,
PBET3 TYPE STRING,
PDAT4 TYPE STRING,
PBET4 TYPE STRING,
PDAT5 TYPE STRING,
PBET5 TYPE STRING,
PDAT6 TYPE STRING,
PBET6 TYPE STRING,
WAE01 TYPE STRING,
WAE02 TYPE STRING,
WAE03 TYPE STRING,
WAE04 TYPE STRING,
WAE05 TYPE STRING,
WAE06 TYPE STRING,
WAE07 TYPE STRING,
WAE08 TYPE STRING,
WAE09 TYPE STRING,
WAE10 TYPE STRING,
WAE11 TYPE STRING,
WAE12 TYPE STRING,
WAE13 TYPE STRING,
WAE14 TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_DE_R0652_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PERNR sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-UNAME sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAERS sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-KGBVN sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-KGBNN sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-KIGNR sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-BEKNZ sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-ABDAU sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-AVDAT sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-AVEIN sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-AVEIB sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-AVEWO sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-REGNR sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-ABPRF sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-APDAT sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-SUERG sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-VLAVH sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-AVEND sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-UNAAV sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-AVBEG sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-TLZEI sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-ARTNL sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT1 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT2 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT3 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT4 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET1 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET2 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET3 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET4 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT5 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT6 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT7 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NDAT8 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET5 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET6 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET7 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-NBET8 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PAULO sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-ARTLE sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PDAT1 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PBET1 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PDAT2 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PBET2 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PDAT3 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PBET3 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PDAT4 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PBET4 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PDAT5 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PBET5 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PDAT6 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-PBET6 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE01 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE02 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE03 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE04 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE05 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE06 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE07 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE08 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE09 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE10 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE11 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE12 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE13 sy-vline
WA_HCMT_BSP_PA_DE_R0652_STR-WAE14 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.