ABAP Select data from SAP table HCMT_BSP_PA_DE_R0271 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_DE_R0271 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_DE_R0271. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_DE_R0271 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_DE_R0271 TYPE STANDARD TABLE OF HCMT_BSP_PA_DE_R0271,
      WA_HCMT_BSP_PA_DE_R0271 TYPE HCMT_BSP_PA_DE_R0271,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_DE_R0271> TYPE HCMT_BSP_PA_DE_R0271.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_DE_R0271.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_DE_R0271
  INTO TABLE IT_HCMT_BSP_PA_DE_R0271.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_DE_R0271
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_DE_R02712).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_DE_R0271 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_DE_R02712).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_DE_R0271 ASSIGNING <HCMT_BSP_PA_DE_R0271>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_DE_R0271>-OBJECT_KEY = 1.
<HCMT_BSP_PA_DE_R0271>-PERNR = 1.
<HCMT_BSP_PA_DE_R0271>-AEDTM = 1.
<HCMT_BSP_PA_DE_R0271>-UNAME = 1.
<HCMT_BSP_PA_DE_R0271>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_DE_R0271 INTO WA_HCMT_BSP_PA_DE_R0271.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_DE_R0271-SPRTX, sy-vline,
WA_HCMT_BSP_PA_DE_R0271-ITBLD, sy-vline,
WA_HCMT_BSP_PA_DE_R0271-ITXEX, sy-vline,
WA_HCMT_BSP_PA_DE_R0271-BEGDA, sy-vline,
WA_HCMT_BSP_PA_DE_R0271-ENDDA, sy-vline,
WA_HCMT_BSP_PA_DE_R0271-SUBTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_DE_R0271 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_DE_R0271 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_DE_R0271 INTO WA_HCMT_BSP_PA_DE_R0271. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GJAHR, internal->external for field ERWJH CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_HCMT_BSP_PA_DE_R0271-ERWJH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HCMT_BSP_PA_DE_R0271-ERWJH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field JDPRZ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_HCMT_BSP_PA_DE_R0271-JDPRZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HCMT_BSP_PA_DE_R0271-JDPRZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field JDPRL CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_HCMT_BSP_PA_DE_R0271-JDPRL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_HCMT_BSP_PA_DE_R0271-JDPRL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_DE_R0271_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
SUBTY TYPE STRING,
STEXT TYPE STRING,
STPRT TYPE STRING,
STTZK TYPE STRING,
AUSK1 TYPE STRING,
AUSK2 TYPE STRING,
AUSK3 TYPE STRING,
AUSK4 TYPE STRING,
AUSK5 TYPE STRING,
VBWZL TYPE STRING,
VBWNE TYPE STRING,
VBWAN TYPE STRING,
VBW02 TYPE STRING,
VBUEB TYPE STRING,
LFBGR TYPE STRING,
ENSTU TYPE STRING,
STEHS TYPE STRING,
ANSTU TYPE STRING,
AFRDV TYPE STRING,
STEVS TYPE STRING,
BSTND TYPE STRING,
GRDEV TYPE STRING,
PZHLA TYPE STRING,
PENRA TYPE STRING,
PRTTX TYPE STRING,
STTZT TYPE STRING,
AUS1T TYPE STRING,
AUS2T TYPE STRING,
AUS3T TYPE STRING,
AUS4T TYPE STRING,
HHABS TYPE STRING,
HNUMM TYPE STRING,
HNUTX TYPE STRING,
SLAND TYPE STRING,
SLATX TYPE STRING,
ERWJH TYPE STRING,
STDBR TYPE STRING,
ARTQP TYPE STRING,
ARTQV TYPE STRING,
POSHL TYPE STRING,
JDPRZ TYPE STRING,
JDPRL TYPE STRING,
VQPLZ TYPE STRING,
ANSTUP TYPE STRING,
FACHDH TYPE STRING,
FACTX TYPE STRING,
ARZTGEBIETSCHWERPUNKT_T TYPE STRING,
ARZTFUNKTION_T TYPE STRING,
NICHTARZTBERUF_T TYPE STRING,
NICHTARZTFUNKTION_T TYPE STRING,
FACHABT_PFLKRAEFTE_KHT TYPE STRING,
WEITERBILDUNG_T TYPE STRING,
BESCHUMFANG TYPE STRING,
ARBEITSZEIT TYPE STRING,
ARZTGEBIETSCHWERPUNKT TYPE STRING,
ARZTFUNKTION TYPE STRING,
NICHTARZTBERUF TYPE STRING,
NICHTARZTFUNKTION TYPE STRING,
FACHABT_PFLKRAEFTE_KH TYPE STRING,
WEITERBILDUNG TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_DE_R0271_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-PERNR sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-UNAME sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-SUBTY sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-STEXT sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-STPRT sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-STTZK sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUSK1 sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUSK2 sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUSK3 sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUSK4 sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUSK5 sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-VBWZL sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-VBWNE sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-VBWAN sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-VBW02 sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-VBUEB sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-LFBGR sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ENSTU sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-STEHS sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ANSTU sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AFRDV sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-STEVS sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-BSTND sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-GRDEV sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-PZHLA sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-PENRA sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-PRTTX sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-STTZT sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUS1T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUS2T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUS3T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-AUS4T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-HHABS sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-HNUMM sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-HNUTX sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-SLAND sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-SLATX sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ERWJH sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-STDBR sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ARTQP sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ARTQV sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-POSHL sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-JDPRZ sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-JDPRL sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-VQPLZ sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ANSTUP sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-FACHDH sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-FACTX sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ARZTGEBIETSCHWERPUNKT_T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ARZTFUNKTION_T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-NICHTARZTBERUF_T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-NICHTARZTFUNKTION_T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-FACHABT_PFLKRAEFTE_KHT sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-WEITERBILDUNG_T sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-BESCHUMFANG sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ARBEITSZEIT sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ARZTGEBIETSCHWERPUNKT sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-ARZTFUNKTION sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-NICHTARZTBERUF sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-NICHTARZTFUNKTION sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-FACHABT_PFLKRAEFTE_KH sy-vline
WA_HCMT_BSP_PA_DE_R0271_STR-WEITERBILDUNG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.