ABAP Select data from SAP table HCMT_BSP_PA_DE_R0124 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_DE_R0124 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_DE_R0124. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_DE_R0124 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_DE_R0124 TYPE STANDARD TABLE OF HCMT_BSP_PA_DE_R0124,
      WA_HCMT_BSP_PA_DE_R0124 TYPE HCMT_BSP_PA_DE_R0124,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_DE_R0124> TYPE HCMT_BSP_PA_DE_R0124.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_DE_R0124.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_DE_R0124
  INTO TABLE IT_HCMT_BSP_PA_DE_R0124.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_DE_R0124
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_DE_R01242).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_DE_R0124 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_DE_R01242).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_DE_R0124 ASSIGNING <HCMT_BSP_PA_DE_R0124>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_DE_R0124>-OBJECT_KEY = 1.
<HCMT_BSP_PA_DE_R0124>-PERNR = 1.
<HCMT_BSP_PA_DE_R0124>-AEDTM = 1.
<HCMT_BSP_PA_DE_R0124>-UNAME = 1.
<HCMT_BSP_PA_DE_R0124>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_DE_R0124 INTO WA_HCMT_BSP_PA_DE_R0124.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_DE_R0124-SPRTX, sy-vline,
WA_HCMT_BSP_PA_DE_R0124-ITBLD, sy-vline,
WA_HCMT_BSP_PA_DE_R0124-ITXEX, sy-vline,
WA_HCMT_BSP_PA_DE_R0124-BEGDA, sy-vline,
WA_HCMT_BSP_PA_DE_R0124-WGSCH, sy-vline,
WA_HCMT_BSP_PA_DE_R0124-WGTXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_DE_R0124 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_DE_R0124 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_DE_R0124 INTO WA_HCMT_BSP_PA_DE_R0124. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_DE_R0124_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
WGSCH TYPE STRING,
WGTXT TYPE STRING,
KVBTR TYPE STRING,
WAE01 TYPE STRING,
RVBTR TYPE STRING,
WAE02 TYPE STRING,
AVBTR TYPE STRING,
WAE03 TYPE STRING,
PVBTR TYPE STRING,
WAE04 TYPE STRING,
KVWAJ TYPE STRING,
WAE05 TYPE STRING,
RVWAJ TYPE STRING,
WAE06 TYPE STRING,
AVWAJ TYPE STRING,
WAE07 TYPE STRING,
PVWAJ TYPE STRING,
WAE08 TYPE STRING,
KVWVJ TYPE STRING,
WAE09 TYPE STRING,
RVWVJ TYPE STRING,
WAE10 TYPE STRING,
AVWVJ TYPE STRING,
WAE11 TYPE STRING,
PVWVJ TYPE STRING,
WAE12 TYPE STRING,
KVKNZ TYPE STRING,
KVSFR TYPE STRING,
KKTXT TYPE STRING,
RVKNZ TYPE STRING,
KVGST TYPE STRING,
TXT01 TYPE STRING,
AVKNZ TYPE STRING,
PVKNZ TYPE STRING,
SVKEY TYPE STRING,
WERKS TYPE STRING,
NAME1 TYPE STRING,
BTRTL TYPE STRING,
BTEXT TYPE STRING,
DATUM TYPE STRING,
MASCH TYPE STRING,
STBTR TYPE STRING,
WAE13 TYPE STRING,
ENDDA TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_DE_R0124_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-PERNR sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-UNAME sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WGSCH sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WGTXT sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-KVBTR sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE01 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-RVBTR sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE02 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-AVBTR sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE03 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-PVBTR sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE04 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-KVWAJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE05 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-RVWAJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE06 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-AVWAJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE07 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-PVWAJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE08 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-KVWVJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE09 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-RVWVJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE10 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-AVWVJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE11 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-PVWVJ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE12 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-KVKNZ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-KVSFR sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-KKTXT sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-RVKNZ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-KVGST sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-TXT01 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-AVKNZ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-PVKNZ sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-SVKEY sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WERKS sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-NAME1 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-BTRTL sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-BTEXT sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-DATUM sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-MASCH sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-STBTR sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-WAE13 sy-vline
WA_HCMT_BSP_PA_DE_R0124_STR-ENDDA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.