ABAP Select data from SAP table HCMT_BSP_PA_CN_R3224 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_CN_R3224 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_CN_R3224. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_CN_R3224 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_CN_R3224 TYPE STANDARD TABLE OF HCMT_BSP_PA_CN_R3224,
      WA_HCMT_BSP_PA_CN_R3224 TYPE HCMT_BSP_PA_CN_R3224,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_CN_R3224> TYPE HCMT_BSP_PA_CN_R3224.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_CN_R3224.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_CN_R3224
  INTO TABLE IT_HCMT_BSP_PA_CN_R3224.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_CN_R3224
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_CN_R32242).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_CN_R3224 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_CN_R32242).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_CN_R3224 ASSIGNING <HCMT_BSP_PA_CN_R3224>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_CN_R3224>-OBJECT_KEY = 1.
<HCMT_BSP_PA_CN_R3224>-PERNR = 1.
<HCMT_BSP_PA_CN_R3224>-AEDTM = 1.
<HCMT_BSP_PA_CN_R3224>-UNAME = 1.
<HCMT_BSP_PA_CN_R3224>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_CN_R3224 INTO WA_HCMT_BSP_PA_CN_R3224.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_CN_R3224-SPRTX, sy-vline,
WA_HCMT_BSP_PA_CN_R3224-ITBLD, sy-vline,
WA_HCMT_BSP_PA_CN_R3224-ITXEX, sy-vline,
WA_HCMT_BSP_PA_CN_R3224-BEGDA, sy-vline,
WA_HCMT_BSP_PA_CN_R3224-ENDDA, sy-vline,
WA_HCMT_BSP_PA_CN_R3224-INFTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_CN_R3224 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_CN_R3224 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_CN_R3224 INTO WA_HCMT_BSP_PA_CN_R3224. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_CN_R3224_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SEQNR TYPE STRING,
TMNGRP TYPE STRING,
TMNGRPT TYPE STRING,
TMNRSN TYPE STRING,
TMNRSNT TYPE STRING,
DECTYP TYPE STRING,
DECTYPT TYPE STRING,
DECMKRNM TYPE STRING,
DECMKR TYPE STRING,
IVGBEGDA TYPE STRING,
IVGENDDA TYPE STRING,
DECMKDT TYPE STRING,
OUTCM TYPE STRING,
OUTCMT TYPE STRING,
ACTN TYPE STRING,
INDPY TYPE STRING,
SPCAG TYPE STRING,
BLKLT TYPE STRING,
PECUR TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_CN_R3224_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-PERNR sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-UNAME sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-INFTY sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-SUBTY sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-OBJPS sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-SEQNR sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-TMNGRP sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-TMNGRPT sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-TMNRSN sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-TMNRSNT sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-DECTYP sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-DECTYPT sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-DECMKRNM sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-DECMKR sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-IVGBEGDA sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-IVGENDDA sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-DECMKDT sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-OUTCM sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-OUTCMT sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-ACTN sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-INDPY sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-SPCAG sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-BLKLT sy-vline
WA_HCMT_BSP_PA_CN_R3224_STR-PECUR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.