ABAP Select data from SAP table HCMT_BSP_PA_CN_R0536 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_CN_R0536 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_CN_R0536. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_CN_R0536 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_CN_R0536 TYPE STANDARD TABLE OF HCMT_BSP_PA_CN_R0536,
      WA_HCMT_BSP_PA_CN_R0536 TYPE HCMT_BSP_PA_CN_R0536,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_CN_R0536> TYPE HCMT_BSP_PA_CN_R0536.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_CN_R0536.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_CN_R0536
  INTO TABLE IT_HCMT_BSP_PA_CN_R0536.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_CN_R0536
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_CN_R05362).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_CN_R0536 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_CN_R05362).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_CN_R0536 ASSIGNING <HCMT_BSP_PA_CN_R0536>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_CN_R0536>-OBJECT_KEY = 1.
<HCMT_BSP_PA_CN_R0536>-PERNR = 1.
<HCMT_BSP_PA_CN_R0536>-AEDTM = 1.
<HCMT_BSP_PA_CN_R0536>-UNAME = 1.
<HCMT_BSP_PA_CN_R0536>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_CN_R0536 INTO WA_HCMT_BSP_PA_CN_R0536.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_CN_R0536-SPRTX, sy-vline,
WA_HCMT_BSP_PA_CN_R0536-ITBLD, sy-vline,
WA_HCMT_BSP_PA_CN_R0536-ITXEX, sy-vline,
WA_HCMT_BSP_PA_CN_R0536-BEGDA, sy-vline,
WA_HCMT_BSP_PA_CN_R0536-ENDDA, sy-vline,
WA_HCMT_BSP_PA_CN_R0536-POSTE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_CN_R0536 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_CN_R0536 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_CN_R0536 INTO WA_HCMT_BSP_PA_CN_R0536. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_CN_R0536_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
POSTE TYPE STRING,
POSNA TYPE STRING,
POSTY TYPE STRING,
POSNC TYPE STRING,
PSHTY TYPE STRING,
POSLV TYPE STRING,
JOBTY TYPE STRING,
POSTT TYPE STRING,
JOBDS TYPE STRING,
POSSC TYPE STRING,
PSHTT TYPE STRING,
APPMD TYPE STRING,
APPRS TYPE STRING,
APPNO TYPE STRING,
APPUT TYPE STRING,
APPRU TYPE STRING,
PRIPS TYPE STRING,
HTPOS TYPE STRING,
RMVMD TYPE STRING,
RMVRS TYPE STRING,
RMVNO TYPE STRING,
RMVAP TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_CN_R0536_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-PERNR sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-UNAME sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-POSTE sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-POSNA sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-POSTY sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-POSNC sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-PSHTY sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-POSLV sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-JOBTY sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-POSTT sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-JOBDS sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-POSSC sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-PSHTT sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-APPMD sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-APPRS sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-APPNO sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-APPUT sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-APPRU sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-PRIPS sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-HTPOS sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-RMVMD sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-RMVRS sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-RMVNO sy-vline
WA_HCMT_BSP_PA_CN_R0536_STR-RMVAP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.