ABAP Select data from SAP table HCMT_BSP_PA_BG_R0935 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_BG_R0935 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_BG_R0935. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_BG_R0935 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_BG_R0935 TYPE STANDARD TABLE OF HCMT_BSP_PA_BG_R0935,
      WA_HCMT_BSP_PA_BG_R0935 TYPE HCMT_BSP_PA_BG_R0935,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_BG_R0935> TYPE HCMT_BSP_PA_BG_R0935.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_BG_R0935.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_BG_R0935
  INTO TABLE IT_HCMT_BSP_PA_BG_R0935.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_BG_R0935
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_BG_R09352).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_BG_R0935 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_BG_R09352).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_BG_R0935 ASSIGNING <HCMT_BSP_PA_BG_R0935>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_BG_R0935>-OBJECT_KEY = 1.
<HCMT_BSP_PA_BG_R0935>-PERNR = 1.
<HCMT_BSP_PA_BG_R0935>-AEDTM = 1.
<HCMT_BSP_PA_BG_R0935>-UNAME = 1.
<HCMT_BSP_PA_BG_R0935>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_BG_R0935 INTO WA_HCMT_BSP_PA_BG_R0935.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_BG_R0935-SPRTX, sy-vline,
WA_HCMT_BSP_PA_BG_R0935-ITBLD, sy-vline,
WA_HCMT_BSP_PA_BG_R0935-ITXEX, sy-vline,
WA_HCMT_BSP_PA_BG_R0935-BEGDA, sy-vline,
WA_HCMT_BSP_PA_BG_R0935-ENDDA, sy-vline,
WA_HCMT_BSP_PA_BG_R0935-CTTYP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_BG_R0935 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_BG_R0935 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_BG_R0935 INTO WA_HCMT_BSP_PA_BG_R0935. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_BG_R0935_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
CTTYP TYPE STRING,
CTTYT TYPE STRING,
CTNAP TYPE STRING,
CTNAT TYPE STRING,
LIMIT TYPE STRING,
PRBPX TYPE STRING,
WTTKL TYPE STRING,
NORMC TYPE STRING,
STOPI TYPE STRING,
CTNUM TYPE STRING,
ADNUM TYPE STRING,
CONCD TYPE STRING,
SIGND TYPE STRING,
TERMD TYPE STRING,
ORNUM TYPE STRING,
NAPST TYPE STRING,
RCTNA TYPE STRING,
RCONC TYPE STRING,
RSIGN TYPE STRING,
PRBPR TYPE STRING,
PRBUR TYPE STRING,
PURTX TYPE STRING,
PRBDR TYPE STRING,
PRBPE TYPE STRING,
PRBUE TYPE STRING,
PUETX TYPE STRING,
PRBDE TYPE STRING,
NOTPR TYPE STRING,
NOTUR TYPE STRING,
NURTX TYPE STRING,
NOTDR TYPE STRING,
NOTPE TYPE STRING,
NOTUE TYPE STRING,
NUETX TYPE STRING,
NOTDE TYPE STRING,
ACTTY TYPE STRING,
ACTTX TYPE STRING,
PROFF TYPE STRING,
PROTX TYPE STRING,
LABCA TYPE STRING,
ASPER TYPE STRING,
ASPTX TYPE STRING,
PLWRK TYPE STRING,
PYSYS TYPE STRING,
INCCO TYPE STRING,
INCCT TYPE STRING,
TMSYS TYPE STRING,
TMFRM TYPE STRING,
TMFRD TYPE STRING,
NORMH TYPE STRING,
EKATT TYPE STRING,
EKATX TYPE STRING,
LOSFY TYPE STRING,
LOSFM TYPE STRING,
LOSFD TYPE STRING,
TERMR TYPE STRING,
TERTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_BG_R0935_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PERNR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-UNAME sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-CTTYP sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-CTTYT sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-CTNAP sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-CTNAT sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-LIMIT sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PRBPX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-WTTKL sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NORMC sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-STOPI sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-CTNUM sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ADNUM sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-CONCD sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-SIGND sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-TERMD sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ORNUM sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NAPST sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-RCTNA sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-RCONC sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-RSIGN sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PRBPR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PRBUR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PURTX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PRBDR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PRBPE sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PRBUE sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PUETX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PRBDE sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NOTPR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NOTUR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NURTX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NOTDR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NOTPE sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NOTUE sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NUETX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NOTDE sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ACTTY sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ACTTX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PROFF sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PROTX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-LABCA sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ASPER sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-ASPTX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PLWRK sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-PYSYS sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-INCCO sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-INCCT sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-TMSYS sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-TMFRM sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-TMFRD sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-NORMH sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-EKATT sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-EKATX sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-LOSFY sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-LOSFM sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-LOSFD sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-TERMR sy-vline
WA_HCMT_BSP_PA_BG_R0935_STR-TERTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.