ABAP Select data from SAP table HCMT_BSP_PA_BE_R0107 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_BE_R0107 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_BE_R0107. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_BE_R0107 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_BE_R0107 TYPE STANDARD TABLE OF HCMT_BSP_PA_BE_R0107,
      WA_HCMT_BSP_PA_BE_R0107 TYPE HCMT_BSP_PA_BE_R0107,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_BE_R0107> TYPE HCMT_BSP_PA_BE_R0107.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_BE_R0107.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_BE_R0107
  INTO TABLE IT_HCMT_BSP_PA_BE_R0107.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_BE_R0107
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_BE_R01072).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_BE_R0107 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_BE_R01072).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_BE_R0107 ASSIGNING <HCMT_BSP_PA_BE_R0107>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_BE_R0107>-OBJECT_KEY = 1.
<HCMT_BSP_PA_BE_R0107>-PERNR = 1.
<HCMT_BSP_PA_BE_R0107>-AEDTM = 1.
<HCMT_BSP_PA_BE_R0107>-UNAME = 1.
<HCMT_BSP_PA_BE_R0107>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_BE_R0107 INTO WA_HCMT_BSP_PA_BE_R0107.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_BE_R0107-SPRTX, sy-vline,
WA_HCMT_BSP_PA_BE_R0107-ITBLD, sy-vline,
WA_HCMT_BSP_PA_BE_R0107-ITXEX, sy-vline,
WA_HCMT_BSP_PA_BE_R0107-BEGDA, sy-vline,
WA_HCMT_BSP_PA_BE_R0107-ENDDA, sy-vline,
WA_HCMT_BSP_PA_BE_R0107-BESTE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_BE_R0107 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_BE_R0107 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_BE_R0107 INTO WA_HCMT_BSP_PA_BE_R0107. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_BE_R0107_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
BESTE TYPE STRING,
BERGM TYPE STRING,
BEREG TYPE STRING,
FIXVA TYPE STRING,
PPAID TYPE STRING,
BEUW2 TYPE STRING,
REMES TYPE STRING,
RFSCH TYPE STRING,
SHFTW TYPE STRING,
REMTY TYPE STRING,
RCAIN TYPE STRING,
TMPFT TYPE STRING,
ILLDT TYPE STRING,
ESWDS TYPE STRING,
ESMWH TYPE STRING,
ESWDS_SF TYPE STRING,
ESMWH_SF TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_BE_R0107_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-PERNR sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-UNAME sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-BESTE sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-BERGM sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-BEREG sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-FIXVA sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-PPAID sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-BEUW2 sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-REMES sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-RFSCH sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-SHFTW sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-REMTY sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-RCAIN sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-TMPFT sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ILLDT sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ESWDS sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ESMWH sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ESWDS_SF sy-vline
WA_HCMT_BSP_PA_BE_R0107_STR-ESMWH_SF sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.