ABAP Select data from SAP table HCMT_BSP_PA_AU_R0626_SUB_C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_AU_R0626_SUB_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_AU_R0626_SUB_C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_AU_R0626_SUB_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_AU_R0626_SUB_C TYPE STANDARD TABLE OF HCMT_BSP_PA_AU_R0626_SUB_C,
      WA_HCMT_BSP_PA_AU_R0626_SUB_C TYPE HCMT_BSP_PA_AU_R0626_SUB_C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_AU_R0626_SUB_C> TYPE HCMT_BSP_PA_AU_R0626_SUB_C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_AU_R0626_SUB_C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_AU_R0626_SUB_C
  INTO TABLE IT_HCMT_BSP_PA_AU_R0626_SUB_C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_AU_R0626_SUB_C
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_AU_R0626_SUB_C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_AU_R0626_SUB_C INDEX 1 INTO DATA(WA_HCMT_BSP_PA_AU_R0626_SUB_C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_AU_R0626_SUB_C ASSIGNING <HCMT_BSP_PA_AU_R0626_SUB_C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_AU_R0626_SUB_C>-PYEDP = 1.
<HCMT_BSP_PA_AU_R0626_SUB_C>-PYE83 = 1.
<HCMT_BSP_PA_AU_R0626_SUB_C>-PYEDS = 1.
<HCMT_BSP_PA_AU_R0626_SUB_C>-PYU83 = 1.
<HCMT_BSP_PA_AU_R0626_SUB_C>-PYP83 = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_AU_R0626_SUB_C INTO WA_HCMT_BSP_PA_AU_R0626_SUB_C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_AU_R0626_SUB_C-PYT83, sy-vline,
WA_HCMT_BSP_PA_AU_R0626_SUB_C-PYA83, sy-vline,
WA_HCMT_BSP_PA_AU_R0626_SUB_C-PYI94, sy-vline,
WA_HCMT_BSP_PA_AU_R0626_SUB_C-PYCGT, sy-vline,
WA_HCMT_BSP_PA_AU_R0626_SUB_C-PYEGR, sy-vline,
WA_HCMT_BSP_PA_AU_R0626_SUB_C-PYNQC, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_AU_R0626_SUB_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_AU_R0626_SUB_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_AU_R0626_SUB_C INTO WA_HCMT_BSP_PA_AU_R0626_SUB_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_AU_R0626_SUB_C_STR,
PYEDP TYPE STRING,
PYE83 TYPE STRING,
PYEDS TYPE STRING,
PYU83 TYPE STRING,
PYP83 TYPE STRING,
PYT83 TYPE STRING,
PYA83 TYPE STRING,
PYI94 TYPE STRING,
PYCGT TYPE STRING,
PYEGR TYPE STRING,
PYNQC TYPE STRING,
PYETA TYPE STRING,
PYUCO TYPE STRING,
PYEAS TYPE STRING,
PYCON TYPE STRING,
PYDEA TYPE STRING,
PYDTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYEDP sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYE83 sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYEDS sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYU83 sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYP83 sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYT83 sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYA83 sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYI94 sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYCGT sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYEGR sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYNQC sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYETA sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYUCO sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYEAS sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYCON sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYDEA sy-vline
WA_HCMT_BSP_PA_AU_R0626_SUB_C_STR-PYDTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.