ABAP Select data from SAP table HCMT_BSP_PA_AT_R0131 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_AT_R0131 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_AT_R0131. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HCMT_BSP_PA_AT_R0131 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HCMT_BSP_PA_AT_R0131 TYPE STANDARD TABLE OF HCMT_BSP_PA_AT_R0131,
      WA_HCMT_BSP_PA_AT_R0131 TYPE HCMT_BSP_PA_AT_R0131,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HCMT_BSP_PA_AT_R0131> TYPE HCMT_BSP_PA_AT_R0131.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_AT_R0131.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HCMT_BSP_PA_AT_R0131
  INTO TABLE IT_HCMT_BSP_PA_AT_R0131.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HCMT_BSP_PA_AT_R0131
*  INTO TABLE @DATA(IT_HCMT_BSP_PA_AT_R01312).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HCMT_BSP_PA_AT_R0131 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_AT_R01312).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HCMT_BSP_PA_AT_R0131 ASSIGNING <HCMT_BSP_PA_AT_R0131>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_AT_R0131>-OBJECT_KEY = 1.
<HCMT_BSP_PA_AT_R0131>-PERNR = 1.
<HCMT_BSP_PA_AT_R0131>-AEDTM = 1.
<HCMT_BSP_PA_AT_R0131>-UNAME = 1.
<HCMT_BSP_PA_AT_R0131>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_HCMT_BSP_PA_AT_R0131 INTO WA_HCMT_BSP_PA_AT_R0131.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HCMT_BSP_PA_AT_R0131-SPRTX, sy-vline,
WA_HCMT_BSP_PA_AT_R0131-ITBLD, sy-vline,
WA_HCMT_BSP_PA_AT_R0131-ITXEX, sy-vline,
WA_HCMT_BSP_PA_AT_R0131-BEGDA, sy-vline,
WA_HCMT_BSP_PA_AT_R0131-ENDDA, sy-vline,
WA_HCMT_BSP_PA_AT_R0131-SUBTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_AT_R0131 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_AT_R0131 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_AT_R0131 INTO WA_HCMT_BSP_PA_AT_R0131. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_AT_R0131_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
SUBTY TYPE STRING,
PFART TYPE STRING,
PFNUM TYPE STRING,
STEXT TYPE STRING,
PFSTA TYPE STRING,
PFEND TYPE STRING,
PFDAT TYPE STRING,
PFRNG TYPE STRING,
DRITT TYPE STRING,
DAT3J TYPE STRING,
PFWAE TYPE STRING,
GLKEY TYPE STRING,
ANTXT TYPE STRING,
GLFIR TYPE STRING,
GLABT TYPE STRING,
GLANR TYPE STRING,
GLTIT TYPE STRING,
GLVOR TYPE STRING,
GLNAM TYPE STRING,
GLSTR TYPE STRING,
GLLND TYPE STRING,
GLPLZ TYPE STRING,
GLORT TYPE STRING,
GLTEL TYPE STRING,
KORRE TYPE STRING,
GBKEY TYPE STRING,
GBANTXT TYPE STRING,
GERBE TYPE STRING,
AKTZE TYPE STRING,
PFVOM TYPE STRING,
AKTGL TYPE STRING,
KOKEY TYPE STRING,
KOANTXT TYPE STRING,
KOFIR TYPE STRING,
KOABT TYPE STRING,
KOANR TYPE STRING,
KOTIT TYPE STRING,
KOVOR TYPE STRING,
KONAM TYPE STRING,
KOSTR TYPE STRING,
KOLND TYPE STRING,
KOPLZ TYPE STRING,
KOORT TYPE STRING,
KOTEL TYPE STRING,
PFLEG TYPE STRING,
VERTN TYPE STRING,
KOLNX TYPE STRING,
GLLNX TYPE STRING,
SW134 TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_AT_R0131_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PERNR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-UNAME sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-SUBTY sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFART sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFNUM sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-STEXT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFSTA sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFEND sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFDAT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFRNG sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-DRITT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-DAT3J sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFWAE sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLKEY sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-ANTXT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLFIR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLABT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLANR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLTIT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLVOR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLNAM sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLSTR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLLND sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLPLZ sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLORT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLTEL sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KORRE sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GBKEY sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GBANTXT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GERBE sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-AKTZE sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFVOM sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-AKTGL sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOKEY sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOANTXT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOFIR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOABT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOANR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOTIT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOVOR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KONAM sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOSTR sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOLND sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOPLZ sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOORT sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOTEL sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-PFLEG sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-VERTN sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-KOLNX sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-GLLNX sy-vline
WA_HCMT_BSP_PA_AT_R0131_STR-SW134 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.