ABAP Select data from SAP table HAP_S_DYNP_3100_TBH into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP HAP_S_DYNP_3100_TBH table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HAP_S_DYNP_3100_TBH. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the HAP_S_DYNP_3100_TBH table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_HAP_S_DYNP_3100_TBH TYPE STANDARD TABLE OF HAP_S_DYNP_3100_TBH,
      WA_HAP_S_DYNP_3100_TBH TYPE HAP_S_DYNP_3100_TBH,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <HAP_S_DYNP_3100_TBH> TYPE HAP_S_DYNP_3100_TBH.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_HAP_S_DYNP_3100_TBH.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM HAP_S_DYNP_3100_TBH
  INTO TABLE IT_HAP_S_DYNP_3100_TBH.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM HAP_S_DYNP_3100_TBH
*  INTO TABLE @DATA(IT_HAP_S_DYNP_3100_TBH2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_HAP_S_DYNP_3100_TBH INDEX 1 INTO DATA(WA_HAP_S_DYNP_3100_TBH2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_HAP_S_DYNP_3100_TBH ASSIGNING <HAP_S_DYNP_3100_TBH>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<HAP_S_DYNP_3100_TBH>-COL_01_TXT = 1.
<HAP_S_DYNP_3100_TBH>-COL_01_TEXT = 1.
<HAP_S_DYNP_3100_TBH>-COL_01_NOTE = 1.
<HAP_S_DYNP_3100_TBH>-COL_02_TXT = 1.
<HAP_S_DYNP_3100_TBH>-COL_02_TEXT = 1.
ENDLOOP.

LOOP AT IT_HAP_S_DYNP_3100_TBH INTO WA_HAP_S_DYNP_3100_TBH.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_HAP_S_DYNP_3100_TBH-COL_02_NOTE, sy-vline,
WA_HAP_S_DYNP_3100_TBH-COL_03_TXT, sy-vline,
WA_HAP_S_DYNP_3100_TBH-COL_03_TEXT, sy-vline,
WA_HAP_S_DYNP_3100_TBH-COL_03_NOTE, sy-vline,
WA_HAP_S_DYNP_3100_TBH-COL_04_TXT, sy-vline,
WA_HAP_S_DYNP_3100_TBH-COL_04_TEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HAP_S_DYNP_3100_TBH you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HAP_S_DYNP_3100_TBH TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HAP_S_DYNP_3100_TBH INTO WA_HAP_S_DYNP_3100_TBH. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HAP_S_DYNP_3100_TBH_STR,
COL_01_TXT TYPE STRING,
COL_01_TEXT TYPE STRING,
COL_01_NOTE TYPE STRING,
COL_02_TXT TYPE STRING,
COL_02_TEXT TYPE STRING,
COL_02_NOTE TYPE STRING,
COL_03_TXT TYPE STRING,
COL_03_TEXT TYPE STRING,
COL_03_NOTE TYPE STRING,
COL_04_TXT TYPE STRING,
COL_04_TEXT TYPE STRING,
COL_04_NOTE TYPE STRING,
COL_05_TXT TYPE STRING,
COL_05_TEXT TYPE STRING,
COL_05_NOTE TYPE STRING,
COL_06_TXT TYPE STRING,
COL_06_TEXT TYPE STRING,
COL_06_NOTE TYPE STRING,
COL_07_TXT TYPE STRING,
COL_07_TEXT TYPE STRING,
COL_07_NOTE TYPE STRING,
COL_08_TXT TYPE STRING,
COL_08_TEXT TYPE STRING,
COL_08_NOTE TYPE STRING,
COL_09_TXT TYPE STRING,
COL_09_TEXT TYPE STRING,
COL_09_NOTE TYPE STRING,
COL_10_TXT TYPE STRING,
COL_10_TEXT TYPE STRING,
COL_10_NOTE TYPE STRING,
COL_11_TXT TYPE STRING,
COL_11_TEXT TYPE STRING,
COL_11_NOTE TYPE STRING,
COL_12_TXT TYPE STRING,
COL_12_TEXT TYPE STRING,
COL_12_NOTE TYPE STRING,
COL_13_TXT TYPE STRING,
COL_13_TEXT TYPE STRING,
COL_13_NOTE TYPE STRING,
COL_14_TXT TYPE STRING,
COL_14_TEXT TYPE STRING,
COL_14_NOTE TYPE STRING,
COL_15_TXT TYPE STRING,
COL_15_TEXT TYPE STRING,
COL_15_NOTE TYPE STRING,
COL_16_TXT TYPE STRING,
COL_16_TEXT TYPE STRING,
COL_16_NOTE TYPE STRING,
COL_17_TXT TYPE STRING,
COL_17_TEXT TYPE STRING,
COL_17_NOTE TYPE STRING,
COL_18_TXT TYPE STRING,
COL_18_TEXT TYPE STRING,
COL_18_NOTE TYPE STRING,
COL_19_TXT TYPE STRING,
COL_19_TEXT TYPE STRING,
COL_19_NOTE TYPE STRING,
COL_20_TXT TYPE STRING,
COL_20_TEXT TYPE STRING,
COL_20_NOTE TYPE STRING,END OF T_EKKO_STR. DATA: WA_HAP_S_DYNP_3100_TBH_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_01_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_01_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_01_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_02_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_02_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_02_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_03_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_03_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_03_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_04_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_04_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_04_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_05_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_05_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_05_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_06_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_06_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_06_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_07_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_07_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_07_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_08_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_08_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_08_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_09_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_09_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_09_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_10_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_10_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_10_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_11_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_11_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_11_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_12_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_12_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_12_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_13_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_13_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_13_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_14_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_14_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_14_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_15_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_15_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_15_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_16_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_16_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_16_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_17_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_17_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_17_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_18_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_18_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_18_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_19_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_19_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_19_NOTE sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_20_TXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_20_TEXT sy-vline
WA_HAP_S_DYNP_3100_TBH_STR-COL_20_NOTE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.