ABAP Select data from SAP table H_TICL321_ACTIVE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP H_TICL321_ACTIVE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to H_TICL321_ACTIVE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the H_TICL321_ACTIVE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_H_TICL321_ACTIVE TYPE STANDARD TABLE OF H_TICL321_ACTIVE,
      WA_H_TICL321_ACTIVE TYPE H_TICL321_ACTIVE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <H_TICL321_ACTIVE> TYPE H_TICL321_ACTIVE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_H_TICL321_ACTIVE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM H_TICL321_ACTIVE
  INTO TABLE IT_H_TICL321_ACTIVE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM H_TICL321_ACTIVE
*  INTO TABLE @DATA(IT_H_TICL321_ACTIVE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_H_TICL321_ACTIVE INDEX 1 INTO DATA(WA_H_TICL321_ACTIVE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_H_TICL321_ACTIVE ASSIGNING <H_TICL321_ACTIVE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<H_TICL321_ACTIVE>-CLIENT = 1.
<H_TICL321_ACTIVE>-POLPROD = 1.
<H_TICL321_ACTIVE>-GENERAT = 1.
<H_TICL321_ACTIVE>-VERSION = 1.
<H_TICL321_ACTIVE>-GEFFFROMTIME = 1.
ENDLOOP.

LOOP AT IT_H_TICL321_ACTIVE INTO WA_H_TICL321_ACTIVE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_H_TICL321_ACTIVE-GEFFTOTIME, sy-vline,
WA_H_TICL321_ACTIVE-VEFFFROMTIME, sy-vline,
WA_H_TICL321_ACTIVE-VEFFTOTIME, sy-vline,
WA_H_TICL321_ACTIVE-POLPRODN, sy-vline,
WA_H_TICL321_ACTIVE-PLINEOFBUS, sy-vline,
ENDLOOP. *Add any further fields from structure WA_H_TICL321_ACTIVE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_H_TICL321_ACTIVE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_H_TICL321_ACTIVE INTO WA_H_TICL321_ACTIVE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTAM, internal->external for field GEFFFROMTIME CALL FUNCTION 'CONVERSION_EXIT_TSTAM_OUTPUT' EXPORTING input = WA_H_TICL321_ACTIVE-GEFFFROMTIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_H_TICL321_ACTIVE-GEFFFROMTIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTAM, internal->external for field GEFFTOTIME CALL FUNCTION 'CONVERSION_EXIT_TSTAM_OUTPUT' EXPORTING input = WA_H_TICL321_ACTIVE-GEFFTOTIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_H_TICL321_ACTIVE-GEFFTOTIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTAM, internal->external for field VEFFFROMTIME CALL FUNCTION 'CONVERSION_EXIT_TSTAM_OUTPUT' EXPORTING input = WA_H_TICL321_ACTIVE-VEFFFROMTIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_H_TICL321_ACTIVE-VEFFFROMTIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTAM, internal->external for field VEFFTOTIME CALL FUNCTION 'CONVERSION_EXIT_TSTAM_OUTPUT' EXPORTING input = WA_H_TICL321_ACTIVE-VEFFTOTIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_H_TICL321_ACTIVE-VEFFTOTIME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_H_TICL321_ACTIVE_STR,
CLIENT TYPE STRING,
POLPROD TYPE STRING,
GENERAT TYPE STRING,
VERSION TYPE STRING,
GEFFFROMTIME TYPE STRING,
GEFFTOTIME TYPE STRING,
VEFFFROMTIME TYPE STRING,
VEFFTOTIME TYPE STRING,
POLPRODN TYPE STRING,
PLINEOFBUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_H_TICL321_ACTIVE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_H_TICL321_ACTIVE_STR-CLIENT sy-vline
WA_H_TICL321_ACTIVE_STR-POLPROD sy-vline
WA_H_TICL321_ACTIVE_STR-GENERAT sy-vline
WA_H_TICL321_ACTIVE_STR-VERSION sy-vline
WA_H_TICL321_ACTIVE_STR-GEFFFROMTIME sy-vline
WA_H_TICL321_ACTIVE_STR-GEFFTOTIME sy-vline
WA_H_TICL321_ACTIVE_STR-VEFFFROMTIME sy-vline
WA_H_TICL321_ACTIVE_STR-VEFFTOTIME sy-vline
WA_H_TICL321_ACTIVE_STR-POLPRODN sy-vline
WA_H_TICL321_ACTIVE_STR-PLINEOFBUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.