ABAP Select data from SAP table GTR_FI_BILLDOC_I_DISP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GTR_FI_BILLDOC_I_DISP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GTR_FI_BILLDOC_I_DISP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GTR_FI_BILLDOC_I_DISP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GTR_FI_BILLDOC_I_DISP TYPE STANDARD TABLE OF GTR_FI_BILLDOC_I_DISP,
      WA_GTR_FI_BILLDOC_I_DISP TYPE GTR_FI_BILLDOC_I_DISP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GTR_FI_BILLDOC_I_DISP> TYPE GTR_FI_BILLDOC_I_DISP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GTR_FI_BILLDOC_I_DISP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GTR_FI_BILLDOC_I_DISP
  INTO TABLE IT_GTR_FI_BILLDOC_I_DISP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GTR_FI_BILLDOC_I_DISP
*  INTO TABLE @DATA(IT_GTR_FI_BILLDOC_I_DISP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GTR_FI_BILLDOC_I_DISP INDEX 1 INTO DATA(WA_GTR_FI_BILLDOC_I_DISP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GTR_FI_BILLDOC_I_DISP ASSIGNING <GTR_FI_BILLDOC_I_DISP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GTR_FI_BILLDOC_I_DISP>-MANDT = 1.
<GTR_FI_BILLDOC_I_DISP>-BILLDOCNO = 1.
<GTR_FI_BILLDOC_I_DISP>-BILLDOCITEM = 1.
<GTR_FI_BILLDOC_I_DISP>-BILLDOCITEM_GUID = 1.
<GTR_FI_BILLDOC_I_DISP>-REFDOC_I_ID = 1.
ENDLOOP.

LOOP AT IT_GTR_FI_BILLDOC_I_DISP INTO WA_GTR_FI_BILLDOC_I_DISP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GTR_FI_BILLDOC_I_DISP-REFDOC_I_GUID, sy-vline,
WA_GTR_FI_BILLDOC_I_DISP-REFDOC_I_OBJTP, sy-vline,
WA_GTR_FI_BILLDOC_I_DISP-BILL_AMOUNT, sy-vline,
WA_GTR_FI_BILLDOC_I_DISP-BILL_CURR, sy-vline,
WA_GTR_FI_BILLDOC_I_DISP-FLG_REVERS_ITEM, sy-vline,
WA_GTR_FI_BILLDOC_I_DISP-DATE_FROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GTR_FI_BILLDOC_I_DISP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GTR_FI_BILLDOC_I_DISP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GTR_FI_BILLDOC_I_DISP INTO WA_GTR_FI_BILLDOC_I_DISP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GTR_FI_BILLDOC_I_DISP_STR,
MANDT TYPE STRING,
BILLDOCNO TYPE STRING,
BILLDOCITEM TYPE STRING,
BILLDOCITEM_GUID TYPE STRING,
REFDOC_I_ID TYPE STRING,
REFDOC_I_GUID TYPE STRING,
REFDOC_I_OBJTP TYPE STRING,
BILL_AMOUNT TYPE STRING,
BILL_CURR TYPE STRING,
FLG_REVERS_ITEM TYPE STRING,
DATE_FROM TYPE STRING,
DATE_TO TYPE STRING,
DUE_DATE TYPE STRING,
PAYMENT_TYPE TYPE STRING,
EXPENSE_TYPE TYPE STRING,
BRI_GUID TYPE STRING,
REL_ITEM_GUID TYPE STRING,
REL_ITEM_ID TYPE STRING,
BILLDOC_I_REF TYPE STRING,
EMGPA_GUID TYPE STRING,
ITEM_CLEARED_REF_GUID TYPE STRING,
ITEM_HOLDBACK_REF_GUID TYPE STRING,
REFDOC_I_TXT TYPE STRING,
REF_AGR_I_TXT TYPE STRING,
REF_CLAIM_I_TXT TYPE STRING,
BILLDOC_I_TXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_GTR_FI_BILLDOC_I_DISP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-MANDT sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BILLDOCNO sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BILLDOCITEM sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BILLDOCITEM_GUID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REFDOC_I_ID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REFDOC_I_GUID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REFDOC_I_OBJTP sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BILL_AMOUNT sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BILL_CURR sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-FLG_REVERS_ITEM sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-DATE_FROM sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-DATE_TO sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-DUE_DATE sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-PAYMENT_TYPE sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-EXPENSE_TYPE sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BRI_GUID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REL_ITEM_GUID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REL_ITEM_ID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BILLDOC_I_REF sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-EMGPA_GUID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-ITEM_CLEARED_REF_GUID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-ITEM_HOLDBACK_REF_GUID sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REFDOC_I_TXT sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REF_AGR_I_TXT sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-REF_CLAIM_I_TXT sy-vline
WA_GTR_FI_BILLDOC_I_DISP_STR-BILLDOC_I_TXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.