ABAP Select data from SAP table GTE_ST_GRANT_SMP_BY_ELEMS_Q_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GTE_ST_GRANT_SMP_BY_ELEMS_Q_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GTE_ST_GRANT_SMP_BY_ELEMS_Q_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GTE_ST_GRANT_SMP_BY_ELEMS_Q_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S TYPE STANDARD TABLE OF GTE_ST_GRANT_SMP_BY_ELEMS_Q_S,
      WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S TYPE GTE_ST_GRANT_SMP_BY_ELEMS_Q_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GTE_ST_GRANT_SMP_BY_ELEMS_Q_S> TYPE GTE_ST_GRANT_SMP_BY_ELEMS_Q_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GTE_ST_GRANT_SMP_BY_ELEMS_Q_S
  INTO TABLE IT_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GTE_ST_GRANT_SMP_BY_ELEMS_Q_S
*  INTO TABLE @DATA(IT_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S INDEX 1 INTO DATA(WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S ASSIGNING <GTE_ST_GRANT_SMP_BY_ELEMS_Q_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GTE_ST_GRANT_SMP_BY_ELEMS_Q_S>-CONTROLLER = 1.
<GTE_ST_GRANT_SMP_BY_ELEMS_Q_S>-GRANT_SMP_BY_ELEMENTS_QUERY_S = 1.
<GTE_ST_GRANT_SMP_BY_ELEMS_Q_S>-CONTROLLER = 1.
<GTE_ST_GRANT_SMP_BY_ELEMS_Q_S>-MESSAGE_HEADER = 1.
<GTE_ST_GRANT_SMP_BY_ELEMS_Q_S>-CONTROLLER = 1.
ENDLOOP.

LOOP AT IT_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S INTO WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S-ID, sy-vline,
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S-CONTROLLER, sy-vline,
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S-SCHEME_ID, sy-vline,
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S-SCHEME_AGENCY_ID, sy-vline,
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S-SCHEME_AGENCY_SCHEME_AGENCY_ID, sy-vline,
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S-VALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S INTO WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR,
CONTROLLER TYPE STRING,
GRANT_SMP_BY_ELEMENTS_QUERY_S TYPE STRING,
CONTROLLER TYPE STRING,
MESSAGE_HEADER TYPE STRING,
CONTROLLER TYPE STRING,
ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
UUID TYPE STRING,
REFERENCE_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
REFERENCE_UUID TYPE STRING,
GTE_SMP_SEL_BY_ELEMENTS TYPE STRING,
CONTROLLER TYPE STRING,
GRANT_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
COMPANY_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
GRANTOR_GRANT_NAME TYPE STRING,
PREAWARD_PROCESSING_GRANT_NAME TYPE STRING,
GRANT_NAME TYPE STRING,
CONTROLLER TYPE STRING,
LANGUAGE_CODE TYPE STRING,
VALUE TYPE STRING,
GRANT_VALIDITY_PER_START_DATE TYPE STRING,
GRANT_VALIDITY_PERIOD_END_DATE TYPE STRING,
FUNDING_ORIGIN_NOTE TYPE STRING,
CONTROLLER TYPE STRING,
LANGUAGE_CODE TYPE STRING,
CONTENT TYPE STRING,
CONFIGURATION_PROFILE_CODE TYPE STRING,
CONTROLLER TYPE STRING,
LIST_ID TYPE STRING,
LIST_VERSION_ID TYPE STRING,
LIST_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
LIFE_CYCLE_STATUS_CODE TYPE STRING,
USER_STATUS_CODE TYPE STRING,
CONTROLLER TYPE STRING,
LIST_ID TYPE STRING,
LIST_VERSION_ID TYPE STRING,
LIST_AGENCY_ID TYPE STRING,
LIST_AGENCY_SCHEME_ID TYPE STRING,
LIST_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
AWARD_TYPE_CODE TYPE STRING,
CONTROLLER TYPE STRING,
LIST_ID TYPE STRING,
LIST_VERSION_ID TYPE STRING,
LIST_AGENCY_ID TYPE STRING,
LIST_AGENCY_SCHEME_ID TYPE STRING,
LIST_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
CURRENCY_CODE TYPE STRING,
FEDERAL_DOMESTIC_ASSIST_CODE TYPE STRING,
CONTROLLER TYPE STRING,
LIST_ID TYPE STRING,
LIST_VERSION_ID TYPE STRING,
LIST_AGENCY_ID TYPE STRING,
LIST_AGENCY_SCHEME_ID TYPE STRING,
LIST_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
GRANTOR_INTERNAL_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_ID TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
CONTENT TYPE STRING,
CREATION_DATE TYPE STRING,
CREATION_USER_ACCOUNT_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
LAST_CHANGE_DATE TYPE STRING,
LAST_CHANGE_USER_ACCOUNT_ID TYPE STRING,
CONTROLLER TYPE STRING,
SCHEME_AGENCY_ID TYPE STRING,
SCHEME_AGENCY_SCHEME_AGENCY_ID TYPE STRING,
VALUE TYPE STRING,
SELECTION_BY_GRANT_ID TYPE STRING,
SELBY_GRANTOR_GRANT_NAME TYPE STRING,
SELBY_PREAWARD_PROC_GRANT_NAME TYPE STRING,
SELECTION_BY_GRANT_NAME TYPE STRING,
SELBY_VALIDITY_PER_START_DATE TYPE STRING,
SELBY_VALIDITY_PER_END_DATE TYPE STRING,
SELBY_FUNDING_ORIGIN_NOTE TYPE STRING,
SELBY_LIFECYCLE_STATUS_CODE TYPE STRING,
SELECTION_BY_USER_STATUS_CODE TYPE STRING,
SELBY_GRANT_AWARD_TYPE_CODE TYPE STRING,
SELBY_FDA_CODE TYPE STRING,
SELBY_GRANTOR_ID TYPE STRING,
SELECTION_BY_CREATION_DATE TYPE STRING,
SELBY_CREATION_USER_ID TYPE STRING,
SELECTION_BY_LAST_CHANGE_DATE TYPE STRING,
SELBY_LAST_CHANGE_USER_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GRANT_SMP_BY_ELEMENTS_QUERY_S sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-MESSAGE_HEADER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-VALUE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-UUID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-REFERENCE_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-VALUE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-REFERENCE_UUID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GTE_SMP_SEL_BY_ELEMENTS sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GRANT_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-VALUE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-COMPANY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTENT sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GRANTOR_GRANT_NAME sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-PREAWARD_PROCESSING_GRANT_NAME sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GRANT_NAME sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LANGUAGE_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-VALUE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GRANT_VALIDITY_PER_START_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GRANT_VALIDITY_PERIOD_END_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-FUNDING_ORIGIN_NOTE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LANGUAGE_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTENT sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONFIGURATION_PROFILE_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_VERSION_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTENT sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIFE_CYCLE_STATUS_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-USER_STATUS_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_VERSION_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_SCHEME_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTENT sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-AWARD_TYPE_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_VERSION_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_SCHEME_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTENT sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CURRENCY_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-FEDERAL_DOMESTIC_ASSIST_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_VERSION_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_SCHEME_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LIST_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTENT sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-GRANTOR_INTERNAL_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTENT sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CREATION_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CREATION_USER_ACCOUNT_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-VALUE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LAST_CHANGE_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-LAST_CHANGE_USER_ACCOUNT_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-CONTROLLER sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SCHEME_AGENCY_SCHEME_AGENCY_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-VALUE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELECTION_BY_GRANT_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_GRANTOR_GRANT_NAME sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_PREAWARD_PROC_GRANT_NAME sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELECTION_BY_GRANT_NAME sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_VALIDITY_PER_START_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_VALIDITY_PER_END_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_FUNDING_ORIGIN_NOTE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_LIFECYCLE_STATUS_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELECTION_BY_USER_STATUS_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_GRANT_AWARD_TYPE_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_FDA_CODE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_GRANTOR_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELECTION_BY_CREATION_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_CREATION_USER_ID sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELECTION_BY_LAST_CHANGE_DATE sy-vline
WA_GTE_ST_GRANT_SMP_BY_ELEMS_Q_S_STR-SELBY_LAST_CHANGE_USER_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.