ABAP Select data from SAP table GTCN_FPM_S_POSTLOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GTCN_FPM_S_POSTLOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GTCN_FPM_S_POSTLOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GTCN_FPM_S_POSTLOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GTCN_FPM_S_POSTLOG TYPE STANDARD TABLE OF GTCN_FPM_S_POSTLOG,
      WA_GTCN_FPM_S_POSTLOG TYPE GTCN_FPM_S_POSTLOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GTCN_FPM_S_POSTLOG> TYPE GTCN_FPM_S_POSTLOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GTCN_FPM_S_POSTLOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GTCN_FPM_S_POSTLOG
  INTO TABLE IT_GTCN_FPM_S_POSTLOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GTCN_FPM_S_POSTLOG
*  INTO TABLE @DATA(IT_GTCN_FPM_S_POSTLOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GTCN_FPM_S_POSTLOG INDEX 1 INTO DATA(WA_GTCN_FPM_S_POSTLOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GTCN_FPM_S_POSTLOG ASSIGNING <GTCN_FPM_S_POSTLOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GTCN_FPM_S_POSTLOG>-MANDT = 1.
<GTCN_FPM_S_POSTLOG>-FILE_ID = 1.
<GTCN_FPM_S_POSTLOG>-POST_RUN_ID = 1.
<GTCN_FPM_S_POSTLOG>-BUKRS = 1.
<GTCN_FPM_S_POSTLOG>-COMPANY_NAME = 1.
ENDLOOP.

LOOP AT IT_GTCN_FPM_S_POSTLOG INTO WA_GTCN_FPM_S_POSTLOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GTCN_FPM_S_POSTLOG-INVOICE_NO, sy-vline,
WA_GTCN_FPM_S_POSTLOG-CUST_DECL_DOC_NO, sy-vline,
WA_GTCN_FPM_S_POSTLOG-REFUND_ID, sy-vline,
WA_GTCN_FPM_S_POSTLOG-PERIOD, sy-vline,
WA_GTCN_FPM_S_POSTLOG-BATCH_ID, sy-vline,
WA_GTCN_FPM_S_POSTLOG-EXPORT_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GTCN_FPM_S_POSTLOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GTCN_FPM_S_POSTLOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GTCN_FPM_S_POSTLOG INTO WA_GTCN_FPM_S_POSTLOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field INVOICE_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GTCN_FPM_S_POSTLOG-INVOICE_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GTCN_FPM_S_POSTLOG-INVOICE_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEQ_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GTCN_FPM_S_POSTLOG-SEQ_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GTCN_FPM_S_POSTLOG-SEQ_NO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GTCN_FPM_S_POSTLOG_STR,
MANDT TYPE STRING,
FILE_ID TYPE STRING,
POST_RUN_ID TYPE STRING,
BUKRS TYPE STRING,
COMPANY_NAME TYPE STRING,
INVOICE_NO TYPE STRING,
CUST_DECL_DOC_NO TYPE STRING,
REFUND_ID TYPE STRING,
PERIOD TYPE STRING,
BATCH_ID TYPE STRING,
EXPORT_DATE TYPE STRING,
SEQ_NO TYPE STRING,
CATEGORY TYPE STRING,
CATE_DESC TYPE STRING,
ACCRUAL_AMOUNT TYPE STRING,
ACTUAL_AMOUNT TYPE STRING,
DIFF_AMOUNT TYPE STRING,
COMMISSION_AMOUNT TYPE STRING,
STATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_GTCN_FPM_S_POSTLOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-MANDT sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-FILE_ID sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-POST_RUN_ID sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-BUKRS sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-COMPANY_NAME sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-INVOICE_NO sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-CUST_DECL_DOC_NO sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-REFUND_ID sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-PERIOD sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-BATCH_ID sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-EXPORT_DATE sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-SEQ_NO sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-CATEGORY sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-CATE_DESC sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-ACCRUAL_AMOUNT sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-ACTUAL_AMOUNT sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-DIFF_AMOUNT sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-COMMISSION_AMOUNT sy-vline
WA_GTCN_FPM_S_POSTLOG_STR-STATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.