ABAP Select data from SAP table GSS_RFIDPL15_LIST1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GSS_RFIDPL15_LIST1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GSS_RFIDPL15_LIST1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GSS_RFIDPL15_LIST1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GSS_RFIDPL15_LIST1 TYPE STANDARD TABLE OF GSS_RFIDPL15_LIST1,
      WA_GSS_RFIDPL15_LIST1 TYPE GSS_RFIDPL15_LIST1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GSS_RFIDPL15_LIST1> TYPE GSS_RFIDPL15_LIST1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GSS_RFIDPL15_LIST1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GSS_RFIDPL15_LIST1
  INTO TABLE IT_GSS_RFIDPL15_LIST1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GSS_RFIDPL15_LIST1
*  INTO TABLE @DATA(IT_GSS_RFIDPL15_LIST12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GSS_RFIDPL15_LIST1 INDEX 1 INTO DATA(WA_GSS_RFIDPL15_LIST12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GSS_RFIDPL15_LIST1 ASSIGNING <GSS_RFIDPL15_LIST1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GSS_RFIDPL15_LIST1>-SAKNR = 1.
<GSS_RFIDPL15_LIST1>-SKBEZ = 1.
<GSS_RFIDPL15_LIST1>-WAERS = 1.
<GSS_RFIDPL15_LIST1>-GSBER = 1.
<GSS_RFIDPL15_LIST1>-WAFWAER = 1.
ENDLOOP.

LOOP AT IT_GSS_RFIDPL15_LIST1 INTO WA_GSS_RFIDPL15_LIST1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GSS_RFIDPL15_LIST1-WABUKRS, sy-vline,
WA_GSS_RFIDPL15_LIST1-SAL01, sy-vline,
WA_GSS_RFIDPL15_LIST1-SAL02, sy-vline,
WA_GSS_RFIDPL15_LIST1-SAL03, sy-vline,
WA_GSS_RFIDPL15_LIST1-SAL04, sy-vline,
WA_GSS_RFIDPL15_LIST1-SAL05, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GSS_RFIDPL15_LIST1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GSS_RFIDPL15_LIST1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GSS_RFIDPL15_LIST1 INTO WA_GSS_RFIDPL15_LIST1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL01 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL01 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL01.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL02 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL02 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL02.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL03 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL03 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL03.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL04 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL04 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL04.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL05 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL05 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL05.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL06 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL06 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL06.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL07 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL07 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL07.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL08 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL08 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL08.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL09 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL09 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL09.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL10 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL10 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL10.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL11 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL11.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field SAL12 CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_GSS_RFIDPL15_LIST1-SAL12 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GSS_RFIDPL15_LIST1-SAL12.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GSS_RFIDPL15_LIST1_STR,
SAKNR TYPE STRING,
SKBEZ TYPE STRING,
WAERS TYPE STRING,
GSBER TYPE STRING,
WAFWAER TYPE STRING,
WABUKRS TYPE STRING,
SAL01 TYPE STRING,
SAL02 TYPE STRING,
SAL03 TYPE STRING,
SAL04 TYPE STRING,
SAL05 TYPE STRING,
SAL06 TYPE STRING,
SAL07 TYPE STRING,
SAL08 TYPE STRING,
SAL09 TYPE STRING,
SAL10 TYPE STRING,
SAL11 TYPE STRING,
SAL12 TYPE STRING,END OF T_EKKO_STR. DATA: WA_GSS_RFIDPL15_LIST1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAKNR sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SKBEZ sy-vline
WA_GSS_RFIDPL15_LIST1_STR-WAERS sy-vline
WA_GSS_RFIDPL15_LIST1_STR-GSBER sy-vline
WA_GSS_RFIDPL15_LIST1_STR-WAFWAER sy-vline
WA_GSS_RFIDPL15_LIST1_STR-WABUKRS sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL01 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL02 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL03 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL04 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL05 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL06 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL07 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL08 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL09 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL10 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL11 sy-vline
WA_GSS_RFIDPL15_LIST1_STR-SAL12 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.