ABAP Select data from SAP table GRPDYNP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPDYNP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPDYNP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRPDYNP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRPDYNP TYPE STANDARD TABLE OF GRPDYNP,
      WA_GRPDYNP TYPE GRPDYNP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRPDYNP> TYPE GRPDYNP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRPDYNP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRPDYNP
  INTO TABLE IT_GRPDYNP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRPDYNP
*  INTO TABLE @DATA(IT_GRPDYNP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRPDYNP INDEX 1 INTO DATA(WA_GRPDYNP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRPDYNP ASSIGNING <GRPDYNP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPDYNP>-NAME_0101 = 1.
<GRPDYNP>-NAME_0102 = 1.
<GRPDYNP>-NAME_0103 = 1.
<GRPDYNP>-NAME_0104 = 1.
<GRPDYNP>-NAME_0105 = 1.
ENDLOOP.

LOOP AT IT_GRPDYNP INTO WA_GRPDYNP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRPDYNP-NAME_0106, sy-vline,
WA_GRPDYNP-NAME_0107, sy-vline,
WA_GRPDYNP-NAME_0108, sy-vline,
WA_GRPDYNP-NAME_0109, sy-vline,
WA_GRPDYNP-NAME_0110, sy-vline,
WA_GRPDYNP-NAME_0111, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPDYNP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPDYNP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPDYNP INTO WA_GRPDYNP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPDYNP_STR,
NAME_0101 TYPE STRING,
NAME_0102 TYPE STRING,
NAME_0103 TYPE STRING,
NAME_0104 TYPE STRING,
NAME_0105 TYPE STRING,
NAME_0106 TYPE STRING,
NAME_0107 TYPE STRING,
NAME_0108 TYPE STRING,
NAME_0109 TYPE STRING,
NAME_0110 TYPE STRING,
NAME_0111 TYPE STRING,
NAME_0112 TYPE STRING,
NAME_0113 TYPE STRING,
NAME_0114 TYPE STRING,
NAME_0311 TYPE STRING,
NAME_0312 TYPE STRING,
NAME_0313 TYPE STRING,
NAME_0314 TYPE STRING,
NAME_0315 TYPE STRING,
NAME_0000 TYPE STRING,
NAME_0000V TYPE STRING,
STDHIER TYPE STRING,
NAME_TAB TYPE STRING,
NAME_FIELD TYPE STRING,
SETCLASS TYPE STRING,
SETID TYPE STRING,
NAME_KEYWD TYPE STRING,
NAME_COALL TYPE STRING,
NAME_KEYW1 TYPE STRING,
NAME_COAL1 TYPE STRING,
SUFFIX TYPE STRING,
O_CO_AREA TYPE STRING,
CO_AREA TYPE STRING,
CHACCOUNT TYPE STRING,
FIKRS TYPE STRING,
FIKRS_V TYPE STRING,
MDCHECK TYPE STRING,
BREAKINT TYPE STRING,
SHOWTXT TYPE STRING,
TEXT TYPE STRING,
RVALUE TYPE STRING,
SHOWHEADER TYPE STRING,
WOENDNODES TYPE STRING,
EXPTOLEVEL TYPE STRING,
COUNTLINES TYPE STRING,
GROUPS TYPE STRING,
ALLOCATION TYPE STRING,
REPORTS TYPE STRING,
PLANNING TYPE STRING,
ROLLUP TYPE STRING,
VARIABLES TYPE STRING,
DATASETS TYPE STRING,
VALIDSUB TYPE STRING,
AUTHOBJ TYPE STRING,
CURRENCY TYPE STRING,
CALCBASES TYPE STRING,
DARTVIEWS TYPE STRING,
OTHOBJECTS TYPE STRING,
MDFROM TYPE STRING,
MDTO TYPE STRING,
KEYDATE TYPE STRING,
EXP_FILE TYPE STRING,
WS_FLAG TYPE STRING,
BATCH TYPE STRING,
GRPASS TYPE STRING,
GSETMODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPDYNP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPDYNP_STR-NAME_0101 sy-vline
WA_GRPDYNP_STR-NAME_0102 sy-vline
WA_GRPDYNP_STR-NAME_0103 sy-vline
WA_GRPDYNP_STR-NAME_0104 sy-vline
WA_GRPDYNP_STR-NAME_0105 sy-vline
WA_GRPDYNP_STR-NAME_0106 sy-vline
WA_GRPDYNP_STR-NAME_0107 sy-vline
WA_GRPDYNP_STR-NAME_0108 sy-vline
WA_GRPDYNP_STR-NAME_0109 sy-vline
WA_GRPDYNP_STR-NAME_0110 sy-vline
WA_GRPDYNP_STR-NAME_0111 sy-vline
WA_GRPDYNP_STR-NAME_0112 sy-vline
WA_GRPDYNP_STR-NAME_0113 sy-vline
WA_GRPDYNP_STR-NAME_0114 sy-vline
WA_GRPDYNP_STR-NAME_0311 sy-vline
WA_GRPDYNP_STR-NAME_0312 sy-vline
WA_GRPDYNP_STR-NAME_0313 sy-vline
WA_GRPDYNP_STR-NAME_0314 sy-vline
WA_GRPDYNP_STR-NAME_0315 sy-vline
WA_GRPDYNP_STR-NAME_0000 sy-vline
WA_GRPDYNP_STR-NAME_0000V sy-vline
WA_GRPDYNP_STR-STDHIER sy-vline
WA_GRPDYNP_STR-NAME_TAB sy-vline
WA_GRPDYNP_STR-NAME_FIELD sy-vline
WA_GRPDYNP_STR-SETCLASS sy-vline
WA_GRPDYNP_STR-SETID sy-vline
WA_GRPDYNP_STR-NAME_KEYWD sy-vline
WA_GRPDYNP_STR-NAME_COALL sy-vline
WA_GRPDYNP_STR-NAME_KEYW1 sy-vline
WA_GRPDYNP_STR-NAME_COAL1 sy-vline
WA_GRPDYNP_STR-SUFFIX sy-vline
WA_GRPDYNP_STR-O_CO_AREA sy-vline
WA_GRPDYNP_STR-CO_AREA sy-vline
WA_GRPDYNP_STR-CHACCOUNT sy-vline
WA_GRPDYNP_STR-FIKRS sy-vline
WA_GRPDYNP_STR-FIKRS_V sy-vline
WA_GRPDYNP_STR-MDCHECK sy-vline
WA_GRPDYNP_STR-BREAKINT sy-vline
WA_GRPDYNP_STR-SHOWTXT sy-vline
WA_GRPDYNP_STR-TEXT sy-vline
WA_GRPDYNP_STR-RVALUE sy-vline
WA_GRPDYNP_STR-SHOWHEADER sy-vline
WA_GRPDYNP_STR-WOENDNODES sy-vline
WA_GRPDYNP_STR-EXPTOLEVEL sy-vline
WA_GRPDYNP_STR-COUNTLINES sy-vline
WA_GRPDYNP_STR-GROUPS sy-vline
WA_GRPDYNP_STR-ALLOCATION sy-vline
WA_GRPDYNP_STR-REPORTS sy-vline
WA_GRPDYNP_STR-PLANNING sy-vline
WA_GRPDYNP_STR-ROLLUP sy-vline
WA_GRPDYNP_STR-VARIABLES sy-vline
WA_GRPDYNP_STR-DATASETS sy-vline
WA_GRPDYNP_STR-VALIDSUB sy-vline
WA_GRPDYNP_STR-AUTHOBJ sy-vline
WA_GRPDYNP_STR-CURRENCY sy-vline
WA_GRPDYNP_STR-CALCBASES sy-vline
WA_GRPDYNP_STR-DARTVIEWS sy-vline
WA_GRPDYNP_STR-OTHOBJECTS sy-vline
WA_GRPDYNP_STR-MDFROM sy-vline
WA_GRPDYNP_STR-MDTO sy-vline
WA_GRPDYNP_STR-KEYDATE sy-vline
WA_GRPDYNP_STR-EXP_FILE sy-vline
WA_GRPDYNP_STR-WS_FLAG sy-vline
WA_GRPDYNP_STR-BATCH sy-vline
WA_GRPDYNP_STR-GRPASS sy-vline
WA_GRPDYNP_STR-GSETMODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.