ABAP Select data from SAP table GRPCRULE_TEMP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPCRULE_TEMP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPCRULE_TEMP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRPCRULE_TEMP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRPCRULE_TEMP TYPE STANDARD TABLE OF GRPCRULE_TEMP,
      WA_GRPCRULE_TEMP TYPE GRPCRULE_TEMP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRPCRULE_TEMP> TYPE GRPCRULE_TEMP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRPCRULE_TEMP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRPCRULE_TEMP
  INTO TABLE IT_GRPCRULE_TEMP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRPCRULE_TEMP
*  INTO TABLE @DATA(IT_GRPCRULE_TEMP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRPCRULE_TEMP INDEX 1 INTO DATA(WA_GRPCRULE_TEMP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRPCRULE_TEMP ASSIGNING <GRPCRULE_TEMP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPCRULE_TEMP>-MANDT = 1.
<GRPCRULE_TEMP>-RULEID = 1.
<GRPCRULE_TEMP>-VERSION = 1.
<GRPCRULE_TEMP>-SYSTEMTYPE = 1.
<GRPCRULE_TEMP>-SCRIPT = 1.
ENDLOOP.

LOOP AT IT_GRPCRULE_TEMP INTO WA_GRPCRULE_TEMP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRPCRULE_TEMP-CONNECTOR, sy-vline,
WA_GRPCRULE_TEMP-RULESTATUS, sy-vline,
WA_GRPCRULE_TEMP-RULEGROUP, sy-vline,
WA_GRPCRULE_TEMP-VALIDFROM, sy-vline,
WA_GRPCRULE_TEMP-VALIDTO, sy-vline,
WA_GRPCRULE_TEMP-RISKVALUERELEVAN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPCRULE_TEMP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPCRULE_TEMP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPCRULE_TEMP INTO WA_GRPCRULE_TEMP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPCRULE_TEMP_STR,
MANDT TYPE STRING,
RULEID TYPE STRING,
VERSION TYPE STRING,
SYSTEMTYPE TYPE STRING,
SCRIPT TYPE STRING,
CONNECTOR TYPE STRING,
RULESTATUS TYPE STRING,
RULEGROUP TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
RISKVALUERELEVAN TYPE STRING,
RESPONSEMODE TYPE STRING,
ORIGINAL_RULEID TYPE STRING,
COPYFROM_RULEID TYPE STRING,
CREATEDON TYPE STRING,
CREATETIME TYPE STRING,
CREATEDBY TYPE STRING,
CHANGEDON TYPE STRING,
CHANGETIME TYPE STRING,
CHANGEDBY TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPCRULE_TEMP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPCRULE_TEMP_STR-MANDT sy-vline
WA_GRPCRULE_TEMP_STR-RULEID sy-vline
WA_GRPCRULE_TEMP_STR-VERSION sy-vline
WA_GRPCRULE_TEMP_STR-SYSTEMTYPE sy-vline
WA_GRPCRULE_TEMP_STR-SCRIPT sy-vline
WA_GRPCRULE_TEMP_STR-CONNECTOR sy-vline
WA_GRPCRULE_TEMP_STR-RULESTATUS sy-vline
WA_GRPCRULE_TEMP_STR-RULEGROUP sy-vline
WA_GRPCRULE_TEMP_STR-VALIDFROM sy-vline
WA_GRPCRULE_TEMP_STR-VALIDTO sy-vline
WA_GRPCRULE_TEMP_STR-RISKVALUERELEVAN sy-vline
WA_GRPCRULE_TEMP_STR-RESPONSEMODE sy-vline
WA_GRPCRULE_TEMP_STR-ORIGINAL_RULEID sy-vline
WA_GRPCRULE_TEMP_STR-COPYFROM_RULEID sy-vline
WA_GRPCRULE_TEMP_STR-CREATEDON sy-vline
WA_GRPCRULE_TEMP_STR-CREATETIME sy-vline
WA_GRPCRULE_TEMP_STR-CREATEDBY sy-vline
WA_GRPCRULE_TEMP_STR-CHANGEDON sy-vline
WA_GRPCRULE_TEMP_STR-CHANGETIME sy-vline
WA_GRPCRULE_TEMP_STR-CHANGEDBY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.