ABAP Select data from SAP table GRPCRTA_S_MGLOPURPIR02C1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPCRTA_S_MGLOPURPIR02C1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPCRTA_S_MGLOPURPIR02C1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GRPCRTA_S_MGLOPURPIR02C1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GRPCRTA_S_MGLOPURPIR02C1 TYPE STANDARD TABLE OF GRPCRTA_S_MGLOPURPIR02C1, WA_GRPCRTA_S_MGLOPURPIR02C1 TYPE GRPCRTA_S_MGLOPURPIR02C1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GRPCRTA_S_MGLOPURPIR02C1> TYPE GRPCRTA_S_MGLOPURPIR02C1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GRPCRTA_S_MGLOPURPIR02C1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GRPCRTA_S_MGLOPURPIR02C1 INTO TABLE IT_GRPCRTA_S_MGLOPURPIR02C1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GRPCRTA_S_MGLOPURPIR02C1 * INTO TABLE @DATA(IT_GRPCRTA_S_MGLOPURPIR02C12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GRPCRTA_S_MGLOPURPIR02C1 INDEX 1 INTO DATA(WA_GRPCRTA_S_MGLOPURPIR02C12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GRPCRTA_S_MGLOPURPIR02C1 ASSIGNING <GRPCRTA_S_MGLOPURPIR02C1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPCRTA_S_MGLOPURPIR02C1>-SQNO = 1.
<GRPCRTA_S_MGLOPURPIR02C1>-EBELN = 1.
<GRPCRTA_S_MGLOPURPIR02C1>-BUKRS = 1.
<GRPCRTA_S_MGLOPURPIR02C1>-BUTXT = 1.
<GRPCRTA_S_MGLOPURPIR02C1>-DEFTYP = 1.
ENDLOOP. LOOP AT IT_GRPCRTA_S_MGLOPURPIR02C1 INTO WA_GRPCRTA_S_MGLOPURPIR02C1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GRPCRTA_S_MGLOPURPIR02C1-DEFDESC, sy-vline,
WA_GRPCRTA_S_MGLOPURPIR02C1-WERKS, sy-vline,
WA_GRPCRTA_S_MGLOPURPIR02C1-NAME1, sy-vline,
WA_GRPCRTA_S_MGLOPURPIR02C1-TOTAL_AMOUNT, sy-vline,
WA_GRPCRTA_S_MGLOPURPIR02C1-WAERS, sy-vline,
WA_GRPCRTA_S_MGLOPURPIR02C1-PODATE2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPCRTA_S_MGLOPURPIR02C1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPCRTA_S_MGLOPURPIR02C1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPCRTA_S_MGLOPURPIR02C1 INTO WA_GRPCRTA_S_MGLOPURPIR02C1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GRPCRTA_S_MGLOPURPIR02C1-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GRPCRTA_S_MGLOPURPIR02C1-EBELN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GRPCRTA_S_MGLOPURPIR02C1-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GRPCRTA_S_MGLOPURPIR02C1-LIFNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPCRTA_S_MGLOPURPIR02C1_STR,
SQNO TYPE STRING,
EBELN TYPE STRING,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
DEFTYP TYPE STRING,
DEFDESC TYPE STRING,
WERKS TYPE STRING,
NAME1 TYPE STRING,
TOTAL_AMOUNT TYPE STRING,
WAERS TYPE STRING,
PODATE2 TYPE STRING,
LIFNR TYPE STRING,
ACDES TYPE STRING,
EKORG TYPE STRING,
BSART TYPE STRING,
BATXT TYPE STRING,
ERNAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPCRTA_S_MGLOPURPIR02C1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-SQNO sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-EBELN sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-BUKRS sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-BUTXT sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-DEFTYP sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-DEFDESC sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-WERKS sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-NAME1 sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-TOTAL_AMOUNT sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-WAERS sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-PODATE2 sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-LIFNR sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-ACDES sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-EKORG sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-BSART sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-BATXT sy-vline
WA_GRPCRTA_S_MGLOPURPIR02C1_STR-ERNAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.