ABAP Select data from SAP table GRPCRTA_S_MGLOMMMV06C1 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPCRTA_S_MGLOMMMV06C1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPCRTA_S_MGLOMMMV06C1. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GRPCRTA_S_MGLOMMMV06C1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GRPCRTA_S_MGLOMMMV06C1 TYPE STANDARD TABLE OF GRPCRTA_S_MGLOMMMV06C1, WA_GRPCRTA_S_MGLOMMMV06C1 TYPE GRPCRTA_S_MGLOMMMV06C1, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GRPCRTA_S_MGLOMMMV06C1> TYPE GRPCRTA_S_MGLOMMMV06C1. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GRPCRTA_S_MGLOMMMV06C1. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GRPCRTA_S_MGLOMMMV06C1 INTO TABLE IT_GRPCRTA_S_MGLOMMMV06C1. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GRPCRTA_S_MGLOMMMV06C1 * INTO TABLE @DATA(IT_GRPCRTA_S_MGLOMMMV06C12). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GRPCRTA_S_MGLOMMMV06C1 INDEX 1 INTO DATA(WA_GRPCRTA_S_MGLOMMMV06C12). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GRPCRTA_S_MGLOMMMV06C1 ASSIGNING <GRPCRTA_S_MGLOMMMV06C1>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPCRTA_S_MGLOMMMV06C1>-SEQNO = 1.
<GRPCRTA_S_MGLOMMMV06C1>-MATNM = 1.
<GRPCRTA_S_MGLOMMMV06C1>-MATTP = 1.
<GRPCRTA_S_MGLOMMMV06C1>-WERKS = 1.
<GRPCRTA_S_MGLOMMMV06C1>-NAME1 = 1.
ENDLOOP. LOOP AT IT_GRPCRTA_S_MGLOMMMV06C1 INTO WA_GRPCRTA_S_MGLOMMMV06C1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GRPCRTA_S_MGLOMMMV06C1-DTYPE, sy-vline,
WA_GRPCRTA_S_MGLOMMMV06C1-DTEXT, sy-vline,
WA_GRPCRTA_S_MGLOMMMV06C1-F_OLD, sy-vline,
WA_GRPCRTA_S_MGLOMMMV06C1-F_NEW, sy-vline,
WA_GRPCRTA_S_MGLOMMMV06C1-SALK3, sy-vline,
WA_GRPCRTA_S_MGLOMMMV06C1-PUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPCRTA_S_MGLOMMMV06C1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPCRTA_S_MGLOMMMV06C1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPCRTA_S_MGLOMMMV06C1 INTO WA_GRPCRTA_S_MGLOMMMV06C1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit MATN1, internal->external for field MATNM CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_GRPCRTA_S_MGLOMMMV06C1-MATNM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GRPCRTA_S_MGLOMMMV06C1-MATNM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPCRTA_S_MGLOMMMV06C1_STR,
SEQNO TYPE STRING,
MATNM TYPE STRING,
MATTP TYPE STRING,
WERKS TYPE STRING,
NAME1 TYPE STRING,
DTYPE TYPE STRING,
DTEXT TYPE STRING,
F_OLD TYPE STRING,
F_NEW TYPE STRING,
SALK3 TYPE STRING,
PUNIT TYPE STRING,
LBKUM_PCG TYPE STRING,
CHANGENR TYPE STRING,
BWTAR TYPE STRING,
CDATE TYPE STRING,
CTIME TYPE STRING,
USRID TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPCRTA_S_MGLOMMMV06C1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-SEQNO sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-MATNM sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-MATTP sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-WERKS sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-NAME1 sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-DTYPE sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-DTEXT sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-F_OLD sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-F_NEW sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-SALK3 sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-PUNIT sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-LBKUM_PCG sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-CHANGENR sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-BWTAR sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-CDATE sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-CTIME sy-vline
WA_GRPCRTA_S_MGLOMMMV06C1_STR-USRID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.