ABAP Select data from SAP table GRPCCONTROL_REQUEST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPCCONTROL_REQUEST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPCCONTROL_REQUEST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRPCCONTROL_REQUEST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRPCCONTROL_REQUEST TYPE STANDARD TABLE OF GRPCCONTROL_REQUEST,
      WA_GRPCCONTROL_REQUEST TYPE GRPCCONTROL_REQUEST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRPCCONTROL_REQUEST> TYPE GRPCCONTROL_REQUEST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRPCCONTROL_REQUEST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRPCCONTROL_REQUEST
  INTO TABLE IT_GRPCCONTROL_REQUEST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRPCCONTROL_REQUEST
*  INTO TABLE @DATA(IT_GRPCCONTROL_REQUEST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRPCCONTROL_REQUEST INDEX 1 INTO DATA(WA_GRPCCONTROL_REQUEST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRPCCONTROL_REQUEST ASSIGNING <GRPCCONTROL_REQUEST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPCCONTROL_REQUEST>-CONTROLLER = 1.
<GRPCCONTROL_REQUEST>-CONTROL_INPUT_XML = 1.
<GRPCCONTROL_REQUEST>-CUSTOM_FIELD01 = 1.
<GRPCCONTROL_REQUEST>-CUSTOM_FIELD02 = 1.
<GRPCCONTROL_REQUEST>-CUSTOM_FIELD03 = 1.
ENDLOOP.

LOOP AT IT_GRPCCONTROL_REQUEST INTO WA_GRPCCONTROL_REQUEST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRPCCONTROL_REQUEST-CUSTOM_FIELD04, sy-vline,
WA_GRPCCONTROL_REQUEST-CUSTOM_FIELD05, sy-vline,
WA_GRPCCONTROL_REQUEST-CUSTOM_FIELD06, sy-vline,
WA_GRPCCONTROL_REQUEST-CUSTOM_FIELD07, sy-vline,
WA_GRPCCONTROL_REQUEST-CUSTOM_FIELD08, sy-vline,
WA_GRPCCONTROL_REQUEST-CUSTOM_FIELD09, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPCCONTROL_REQUEST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPCCONTROL_REQUEST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPCCONTROL_REQUEST INTO WA_GRPCCONTROL_REQUEST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPCCONTROL_REQUEST_STR,
CONTROLLER TYPE STRING,
CONTROL_INPUT_XML TYPE STRING,
CUSTOM_FIELD01 TYPE STRING,
CUSTOM_FIELD02 TYPE STRING,
CUSTOM_FIELD03 TYPE STRING,
CUSTOM_FIELD04 TYPE STRING,
CUSTOM_FIELD05 TYPE STRING,
CUSTOM_FIELD06 TYPE STRING,
CUSTOM_FIELD07 TYPE STRING,
CUSTOM_FIELD08 TYPE STRING,
CUSTOM_FIELD09 TYPE STRING,
CUSTOM_FIELD10 TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPCCONTROL_REQUEST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPCCONTROL_REQUEST_STR-CONTROLLER sy-vline
WA_GRPCCONTROL_REQUEST_STR-CONTROL_INPUT_XML sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD01 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD02 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD03 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD04 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD05 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD06 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD07 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD08 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD09 sy-vline
WA_GRPCCONTROL_REQUEST_STR-CUSTOM_FIELD10 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.