ABAP Select data from SAP table GRPC_S_UI_CONTROL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_S_UI_CONTROL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_S_UI_CONTROL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GRPC_S_UI_CONTROL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GRPC_S_UI_CONTROL TYPE STANDARD TABLE OF GRPC_S_UI_CONTROL, WA_GRPC_S_UI_CONTROL TYPE GRPC_S_UI_CONTROL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GRPC_S_UI_CONTROL> TYPE GRPC_S_UI_CONTROL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GRPC_S_UI_CONTROL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GRPC_S_UI_CONTROL INTO TABLE IT_GRPC_S_UI_CONTROL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GRPC_S_UI_CONTROL * INTO TABLE @DATA(IT_GRPC_S_UI_CONTROL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GRPC_S_UI_CONTROL INDEX 1 INTO DATA(WA_GRPC_S_UI_CONTROL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GRPC_S_UI_CONTROL ASSIGNING <GRPC_S_UI_CONTROL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_S_UI_CONTROL>-CN_ALLOW_REFER = 1.
<GRPC_S_UI_CONTROL>-CN_AUTOM = 1.
<GRPC_S_UI_CONTROL>-CN_CATEGORY = 1.
<GRPC_S_UI_CONTROL>-CN_CNGROUP = 1.
<GRPC_S_UI_CONTROL>-CN_CNTR_RISK = 1.
ENDLOOP. LOOP AT IT_GRPC_S_UI_CONTROL INTO WA_GRPC_S_UI_CONTROL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GRPC_S_UI_CONTROL-CN_CNTR_RISK_SS, sy-vline,
WA_GRPC_S_UI_CONTROL-CN_CNTR_RISK_USS, sy-vline,
WA_GRPC_S_UI_CONTROL-CN_D, sy-vline,
WA_GRPC_S_UI_CONTROL-CN_DOC_COUNT, sy-vline,
WA_GRPC_S_UI_CONTROL-CN_DTEVT, sy-vline,
WA_GRPC_S_UI_CONTROL-CN_EVIDENCE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_S_UI_CONTROL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_S_UI_CONTROL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_S_UI_CONTROL INTO WA_GRPC_S_UI_CONTROL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_S_UI_CONTROL_STR,
CN_ALLOW_REFER TYPE STRING,
CN_AUTOM TYPE STRING,
CN_CATEGORY TYPE STRING,
CN_CNGROUP TYPE STRING,
CN_CNTR_RISK TYPE STRING,
CN_CNTR_RISK_SS TYPE STRING,
CN_CNTR_RISK_USS TYPE STRING,
CN_D TYPE STRING,
CN_DOC_COUNT TYPE STRING,
CN_DTEVT TYPE STRING,
CN_EVIDENCE TYPE STRING,
CN_EVIDENCE_SS TYPE STRING,
CN_EVIDENCE_USS TYPE STRING,
CN_EVT_DESC TYPE STRING,
CN_FREQ TYPE STRING,
CN_INPUT TYPE STRING,
CN_IS_CONTROL TYPE STRING,
CN_NATURE TYPE STRING,
CN_OBJECT_ID TYPE STRING,
CN_OUTPUT TYPE STRING,
CN_PURP TYPE STRING,
CN_REG_SPECIFIC TYPE STRING,
CN_SIG TYPE STRING,
CN_T TYPE STRING,
CN_TEST TYPE STRING,
CN_TEST_PLAN TYPE STRING,
CN_TEST_PLAN_T TYPE STRING,
CN_TPROC TYPE STRING,
CN_TSTAUT TYPE STRING,
CN_TTECH TYPE STRING,
CN_VALID_FROM TYPE STRING,
CN_VALID_TO TYPE STRING,
CN_SP TYPE STRING,
CN_SP_T TYPE STRING,
CN_OU TYPE STRING,
CN_OU_T TYPE STRING,
CN_PR TYPE STRING,
CN_PR_T TYPE STRING,
CN_AC_CONTROL_ID TYPE STRING,
CN_AC_BPROC TYPE STRING,
CN_AC_BSUBPROC TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_S_UI_CONTROL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_ALLOW_REFER sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_AUTOM sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_CATEGORY sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_CNGROUP sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_CNTR_RISK sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_CNTR_RISK_SS sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_CNTR_RISK_USS sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_D sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_DOC_COUNT sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_DTEVT sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_EVIDENCE sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_EVIDENCE_SS sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_EVIDENCE_USS sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_EVT_DESC sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_FREQ sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_INPUT sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_IS_CONTROL sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_NATURE sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_OBJECT_ID sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_OUTPUT sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_PURP sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_REG_SPECIFIC sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_SIG sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_T sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_TEST sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_TEST_PLAN sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_TEST_PLAN_T sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_TPROC sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_TSTAUT sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_TTECH sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_VALID_FROM sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_VALID_TO sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_SP sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_SP_T sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_OU sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_OU_T sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_PR sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_PR_T sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_AC_CONTROL_ID sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_AC_BPROC sy-vline
WA_GRPC_S_UI_CONTROL_STR-CN_AC_BSUBPROC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.