ABAP Select data from SAP table GRPC_S_ORGUNIT_PRO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_S_ORGUNIT_PRO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_S_ORGUNIT_PRO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRPC_S_ORGUNIT_PRO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRPC_S_ORGUNIT_PRO TYPE STANDARD TABLE OF GRPC_S_ORGUNIT_PRO,
      WA_GRPC_S_ORGUNIT_PRO TYPE GRPC_S_ORGUNIT_PRO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRPC_S_ORGUNIT_PRO> TYPE GRPC_S_ORGUNIT_PRO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRPC_S_ORGUNIT_PRO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRPC_S_ORGUNIT_PRO
  INTO TABLE IT_GRPC_S_ORGUNIT_PRO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRPC_S_ORGUNIT_PRO
*  INTO TABLE @DATA(IT_GRPC_S_ORGUNIT_PRO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRPC_S_ORGUNIT_PRO INDEX 1 INTO DATA(WA_GRPC_S_ORGUNIT_PRO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRPC_S_ORGUNIT_PRO ASSIGNING <GRPC_S_ORGUNIT_PRO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_S_ORGUNIT_PRO>-ROW_KEY = 1.
<GRPC_S_ORGUNIT_PRO>-PARENT_KEY = 1.
<GRPC_S_ORGUNIT_PRO>-LEAF = 1.
<GRPC_S_ORGUNIT_PRO>-EXPANDED = 1.
<GRPC_S_ORGUNIT_PRO>-SS_ORGUNIT = 1.
ENDLOOP.

LOOP AT IT_GRPC_S_ORGUNIT_PRO INTO WA_GRPC_S_ORGUNIT_PRO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRPC_S_ORGUNIT_PRO-SS_SUBPROCESS, sy-vline,
WA_GRPC_S_ORGUNIT_PRO-SUBPROCESS_ID, sy-vline,
WA_GRPC_S_ORGUNIT_PRO-CONTROL_ID, sy-vline,
WA_GRPC_S_ORGUNIT_PRO-PARENT_ID, sy-vline,
WA_GRPC_S_ORGUNIT_PRO-PARENT_DESCR, sy-vline,
WA_GRPC_S_ORGUNIT_PRO-PROCESS_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_S_ORGUNIT_PRO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_S_ORGUNIT_PRO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_S_ORGUNIT_PRO INTO WA_GRPC_S_ORGUNIT_PRO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_S_ORGUNIT_PRO_STR,
ROW_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
LEAF TYPE STRING,
EXPANDED TYPE STRING,
SS_ORGUNIT TYPE STRING,
SS_SUBPROCESS TYPE STRING,
SUBPROCESS_ID TYPE STRING,
CONTROL_ID TYPE STRING,
PARENT_ID TYPE STRING,
PARENT_DESCR TYPE STRING,
PROCESS_ID TYPE STRING,
PROCESS_DESCR TYPE STRING,
ASSIGN_ID TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
VALIDFROM_ASSIGN TYPE STRING,
VALIDTO_ASSIGN TYPE STRING,
IS_PROVIDER TYPE STRING,
SERVICE_PROVIDER TYPE STRING,
DESCR TYPE STRING,
PRIOX TYPE STRING,
LTEXT TYPE STRING,
INDUSTRY TYPE STRING,
INDUSTRY_SPECIFIC TYPE STRING,
P_METHOD_ASS TYPE STRING,
ASS_METHOD_DESCR TYPE STRING,
TR_TYPE TYPE STRING,
LOCAL_CHANGES TYPE STRING,
LOCAL_CHANGES_DESCR TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_S_ORGUNIT_PRO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-ROW_KEY sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-PARENT_KEY sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-LEAF sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-EXPANDED sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-SS_ORGUNIT sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-SS_SUBPROCESS sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-SUBPROCESS_ID sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-CONTROL_ID sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-PARENT_ID sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-PARENT_DESCR sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-PROCESS_ID sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-PROCESS_DESCR sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-ASSIGN_ID sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-VALIDFROM sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-VALIDTO sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-VALIDFROM_ASSIGN sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-VALIDTO_ASSIGN sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-IS_PROVIDER sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-SERVICE_PROVIDER sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-DESCR sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-PRIOX sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-LTEXT sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-INDUSTRY sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-INDUSTRY_SPECIFIC sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-P_METHOD_ASS sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-ASS_METHOD_DESCR sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-TR_TYPE sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-LOCAL_CHANGES sy-vline
WA_GRPC_S_ORGUNIT_PRO_STR-LOCAL_CHANGES_DESCR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.