ABAP Select data from SAP table GRPC_S_CNTRL_RL_MONITOR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_S_CNTRL_RL_MONITOR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_S_CNTRL_RL_MONITOR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRPC_S_CNTRL_RL_MONITOR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRPC_S_CNTRL_RL_MONITOR TYPE STANDARD TABLE OF GRPC_S_CNTRL_RL_MONITOR,
      WA_GRPC_S_CNTRL_RL_MONITOR TYPE GRPC_S_CNTRL_RL_MONITOR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRPC_S_CNTRL_RL_MONITOR> TYPE GRPC_S_CNTRL_RL_MONITOR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRPC_S_CNTRL_RL_MONITOR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRPC_S_CNTRL_RL_MONITOR
  INTO TABLE IT_GRPC_S_CNTRL_RL_MONITOR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRPC_S_CNTRL_RL_MONITOR
*  INTO TABLE @DATA(IT_GRPC_S_CNTRL_RL_MONITOR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRPC_S_CNTRL_RL_MONITOR INDEX 1 INTO DATA(WA_GRPC_S_CNTRL_RL_MONITOR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRPC_S_CNTRL_RL_MONITOR ASSIGNING <GRPC_S_CNTRL_RL_MONITOR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_S_CNTRL_RL_MONITOR>-ORGID = 1.
<GRPC_S_CNTRL_RL_MONITOR>-ORGNAME = 1.
<GRPC_S_CNTRL_RL_MONITOR>-PROCESSID = 1.
<GRPC_S_CNTRL_RL_MONITOR>-PROCESSNAME = 1.
<GRPC_S_CNTRL_RL_MONITOR>-SUBPROCESSID = 1.
ENDLOOP.

LOOP AT IT_GRPC_S_CNTRL_RL_MONITOR INTO WA_GRPC_S_CNTRL_RL_MONITOR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRPC_S_CNTRL_RL_MONITOR-SUBPROCESSNAME, sy-vline,
WA_GRPC_S_CNTRL_RL_MONITOR-CONTROLID, sy-vline,
WA_GRPC_S_CNTRL_RL_MONITOR-CONTROLNAME, sy-vline,
WA_GRPC_S_CNTRL_RL_MONITOR-TESTAUTOMATION, sy-vline,
WA_GRPC_S_CNTRL_RL_MONITOR-RULEID, sy-vline,
WA_GRPC_S_CNTRL_RL_MONITOR-RULENAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_S_CNTRL_RL_MONITOR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_S_CNTRL_RL_MONITOR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_S_CNTRL_RL_MONITOR INTO WA_GRPC_S_CNTRL_RL_MONITOR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_S_CNTRL_RL_MONITOR_STR,
ORGID TYPE STRING,
ORGNAME TYPE STRING,
PROCESSID TYPE STRING,
PROCESSNAME TYPE STRING,
SUBPROCESSID TYPE STRING,
SUBPROCESSNAME TYPE STRING,
CONTROLID TYPE STRING,
CONTROLNAME TYPE STRING,
TESTAUTOMATION TYPE STRING,
RULEID TYPE STRING,
RULENAME TYPE STRING,
RULESTATUS TYPE STRING,
ACTIVE TYPE STRING,
ISSUE_EXISTS TYPE STRING,
ISSUE_CNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_S_CNTRL_RL_MONITOR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-ORGID sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-ORGNAME sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-PROCESSID sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-PROCESSNAME sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-SUBPROCESSID sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-SUBPROCESSNAME sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-CONTROLID sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-CONTROLNAME sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-TESTAUTOMATION sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-RULEID sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-RULENAME sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-RULESTATUS sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-ACTIVE sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-ISSUE_EXISTS sy-vline
WA_GRPC_S_CNTRL_RL_MONITOR_STR-ISSUE_CNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.