ABAP Select data from SAP table GRPC_RFC_S_RMPLAN_LIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_RFC_S_RMPLAN_LIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_RFC_S_RMPLAN_LIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRPC_RFC_S_RMPLAN_LIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRPC_RFC_S_RMPLAN_LIST TYPE STANDARD TABLE OF GRPC_RFC_S_RMPLAN_LIST,
      WA_GRPC_RFC_S_RMPLAN_LIST TYPE GRPC_RFC_S_RMPLAN_LIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRPC_RFC_S_RMPLAN_LIST> TYPE GRPC_RFC_S_RMPLAN_LIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRPC_RFC_S_RMPLAN_LIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRPC_RFC_S_RMPLAN_LIST
  INTO TABLE IT_GRPC_RFC_S_RMPLAN_LIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRPC_RFC_S_RMPLAN_LIST
*  INTO TABLE @DATA(IT_GRPC_RFC_S_RMPLAN_LIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRPC_RFC_S_RMPLAN_LIST INDEX 1 INTO DATA(WA_GRPC_RFC_S_RMPLAN_LIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRPC_RFC_S_RMPLAN_LIST ASSIGNING <GRPC_RFC_S_RMPLAN_LIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_RFC_S_RMPLAN_LIST>-RE = 1.
<GRPC_RFC_S_RMPLAN_LIST>-RE_T = 1.
<GRPC_RFC_S_RMPLAN_LIST>-ORGUNIT = 1.
<GRPC_RFC_S_RMPLAN_LIST>-ORGUNIT_T = 1.
<GRPC_RFC_S_RMPLAN_LIST>-PRGROUP = 1.
ENDLOOP.

LOOP AT IT_GRPC_RFC_S_RMPLAN_LIST INTO WA_GRPC_RFC_S_RMPLAN_LIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRPC_RFC_S_RMPLAN_LIST-PRGROUP_T, sy-vline,
WA_GRPC_RFC_S_RMPLAN_LIST-MCGROUP, sy-vline,
WA_GRPC_RFC_S_RMPLAN_LIST-MCGROUP_T, sy-vline,
WA_GRPC_RFC_S_RMPLAN_LIST-MCONTROL, sy-vline,
WA_GRPC_RFC_S_RMPLAN_LIST-MCONTROL_T, sy-vline,
WA_GRPC_RFC_S_RMPLAN_LIST-PROCESS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_RFC_S_RMPLAN_LIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_RFC_S_RMPLAN_LIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_RFC_S_RMPLAN_LIST INTO WA_GRPC_RFC_S_RMPLAN_LIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_RFC_S_RMPLAN_LIST_STR,
RE TYPE STRING,
RE_T TYPE STRING,
ORGUNIT TYPE STRING,
ORGUNIT_T TYPE STRING,
PRGROUP TYPE STRING,
PRGROUP_T TYPE STRING,
MCGROUP TYPE STRING,
MCGROUP_T TYPE STRING,
MCONTROL TYPE STRING,
MCONTROL_T TYPE STRING,
PROCESS TYPE STRING,
PROCESS_T TYPE STRING,
CONTROL TYPE STRING,
CONTROL_T TYPE STRING,
ISSUE TYPE STRING,
ISSUE_T TYPE STRING,
RMPLAN TYPE STRING,
RMPLAN_T TYPE STRING,
STATUS TYPE STRING,
STATUS_T TYPE STRING,
RESPONSIBLE TYPE STRING,
RESPONSIBLE_T TYPE STRING,
COMPLETION TYPE STRING,
DESCRIPTION TYPE STRING,
PLAN_COMMENT TYPE STRING,
ENDDATE TYPE STRING,
PROCESSOR TYPE STRING,
TF_YEAR TYPE STRING,
TF_TIMEFRAME TYPE STRING,
EVALUATION TYPE STRING,
EVALUATION_T TYPE STRING,
OBJECT_T TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_RFC_S_RMPLAN_LIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-RE sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-RE_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-ORGUNIT sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-ORGUNIT_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-PRGROUP sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-PRGROUP_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-MCGROUP sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-MCGROUP_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-MCONTROL sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-MCONTROL_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-PROCESS sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-PROCESS_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-CONTROL sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-CONTROL_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-ISSUE sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-ISSUE_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-RMPLAN sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-RMPLAN_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-STATUS sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-STATUS_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-RESPONSIBLE sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-RESPONSIBLE_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-COMPLETION sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-DESCRIPTION sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-PLAN_COMMENT sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-ENDDATE sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-PROCESSOR sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-TF_YEAR sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-TF_TIMEFRAME sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-EVALUATION sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-EVALUATION_T sy-vline
WA_GRPC_RFC_S_RMPLAN_LIST_STR-OBJECT_T sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.