ABAP Select data from SAP table GRPC_DS_S_SUBPROCESS_CONTROLS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_DS_S_SUBPROCESS_CONTROLS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_DS_S_SUBPROCESS_CONTROLS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRPC_DS_S_SUBPROCESS_CONTROLS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRPC_DS_S_SUBPROCESS_CONTROLS TYPE STANDARD TABLE OF GRPC_DS_S_SUBPROCESS_CONTROLS,
      WA_GRPC_DS_S_SUBPROCESS_CONTROLS TYPE GRPC_DS_S_SUBPROCESS_CONTROLS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRPC_DS_S_SUBPROCESS_CONTROLS> TYPE GRPC_DS_S_SUBPROCESS_CONTROLS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRPC_DS_S_SUBPROCESS_CONTROLS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRPC_DS_S_SUBPROCESS_CONTROLS
  INTO TABLE IT_GRPC_DS_S_SUBPROCESS_CONTROLS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRPC_DS_S_SUBPROCESS_CONTROLS
*  INTO TABLE @DATA(IT_GRPC_DS_S_SUBPROCESS_CONTROLS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRPC_DS_S_SUBPROCESS_CONTROLS INDEX 1 INTO DATA(WA_GRPC_DS_S_SUBPROCESS_CONTROLS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRPC_DS_S_SUBPROCESS_CONTROLS ASSIGNING <GRPC_DS_S_SUBPROCESS_CONTROLS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_DS_S_SUBPROCESS_CONTROLS>-NODE = 1.
<GRPC_DS_S_SUBPROCESS_CONTROLS>-NODE_T = 1.
<GRPC_DS_S_SUBPROCESS_CONTROLS>-NODETYPE = 1.
<GRPC_DS_S_SUBPROCESS_CONTROLS>-NODETYPE_T = 1.
<GRPC_DS_S_SUBPROCESS_CONTROLS>-NODETYPE_ICON = 1.
ENDLOOP.

LOOP AT IT_GRPC_DS_S_SUBPROCESS_CONTROLS INTO WA_GRPC_DS_S_SUBPROCESS_CONTROLS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRPC_DS_S_SUBPROCESS_CONTROLS-OBJECT_KEY, sy-vline,
WA_GRPC_DS_S_SUBPROCESS_CONTROLS-PARENT_KEY, sy-vline,
WA_GRPC_DS_S_SUBPROCESS_CONTROLS-IS_EXPANDED, sy-vline,
WA_GRPC_DS_S_SUBPROCESS_CONTROLS-IS_LEAF, sy-vline,
WA_GRPC_DS_S_SUBPROCESS_CONTROLS-TREE_LEVEL, sy-vline,
WA_GRPC_DS_S_SUBPROCESS_CONTROLS-CN_SIG_T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_DS_S_SUBPROCESS_CONTROLS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_DS_S_SUBPROCESS_CONTROLS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_DS_S_SUBPROCESS_CONTROLS INTO WA_GRPC_DS_S_SUBPROCESS_CONTROLS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_DS_S_SUBPROCESS_CONTROLS_STR,
NODE TYPE STRING,
NODE_T TYPE STRING,
NODETYPE TYPE STRING,
NODETYPE_T TYPE STRING,
NODETYPE_ICON TYPE STRING,
OBJECT_KEY TYPE STRING,
PARENT_KEY TYPE STRING,
IS_EXPANDED TYPE STRING,
IS_LEAF TYPE STRING,
TREE_LEVEL TYPE STRING,
CN_SIG_T TYPE STRING,
CN_IS_CONTROL_T TYPE STRING,
CN_PURP_T TYPE STRING,
CN_MATAR_T TYPE STRING,
CN_AUTOM_T TYPE STRING,
CN_FREQ_T TYPE STRING,
CN_NATURE_T TYPE STRING,
CN_TEST_T TYPE STRING,
CN_TTECH_T TYPE STRING,
CN_TSTAUT_T TYPE STRING,
CN_CATEGORY_T TYPE STRING,
CN_EVIDENCE_T TYPE STRING,
CN_EVIDENCE_SS_T TYPE STRING,
CN_CNTR_RISK_T TYPE STRING,
CN_CNTR_RISK_SS_T TYPE STRING,
CN_DTEVT_T TYPE STRING,
CN_RESP_USER_T TYPE STRING,
CN_ALLOW_REFER_T TYPE STRING,
CN_CNGROUP_T TYPE STRING,
CN_SUBGROUP_T TYPE STRING,
CN_TEST_ICON TYPE STRING,
CN_ORIGIN_T TYPE STRING,
CN_SS_OU_T TYPE STRING,
CN_SS_CN_T TYPE STRING,
CN_IS_MONITOR_T TYPE STRING,
CN_IS_COMPLIENC_T TYPE STRING,
CN_REG_SPECIFIC_T TYPE STRING,
CN_RELEVANCE_T TYPE STRING,
CN_TPROC TYPE STRING,
CN_INPUT TYPE STRING,
CN_OUTPUT TYPE STRING,
CN_EVT_DESC TYPE STRING,
CN_SUBGROUP TYPE STRING,
CN_RELEVANCE TYPE STRING,
CN_ASSERTIONS_ID TYPE STRING,
CN_ASSERTIONS TYPE STRING,
CN_T TYPE STRING,
CN_D TYPE STRING,
CONTROL TYPE STRING,
CONTROL_T TYPE STRING,
CONTROL_D TYPE STRING,
TYPE TYPE STRING,
TYPE_T TYPE STRING,
SIG TYPE STRING,
SIG_T TYPE STRING,
AUTOM TYPE STRING,
AUTOM_T TYPE STRING,
FREQ TYPE STRING,
FREQ_T TYPE STRING,
CN TYPE STRING,
CN_SIG TYPE STRING,
CN_IS_CONTROL TYPE STRING,
CN_PURP TYPE STRING,
CN_MATAR TYPE STRING,
CN_AUTOM TYPE STRING,
CN_FREQ TYPE STRING,
CN_NATURE TYPE STRING,
CN_TEST TYPE STRING,
CN_TTECH TYPE STRING,
CN_TSTAUT TYPE STRING,
CN_DTEVT TYPE STRING,
CN_VALID_FROM TYPE STRING,
CN_VALID_TO TYPE STRING,
CN_TEST_PLAN TYPE STRING,
CN_ALLOW_REFER TYPE STRING,
CN_RESP_USER TYPE STRING,
CN_CATEGORY TYPE STRING,
CN_EVIDENCE TYPE STRING,
CN_EVIDENCE_SS TYPE STRING,
CN_CNTR_RISK TYPE STRING,
CN_CNTR_RISK_SS TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-NODE sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-NODE_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-NODETYPE sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-NODETYPE_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-NODETYPE_ICON sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-OBJECT_KEY sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-PARENT_KEY sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-IS_EXPANDED sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-IS_LEAF sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-TREE_LEVEL sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_SIG_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_IS_CONTROL_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_PURP_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_MATAR_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_AUTOM_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_FREQ_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_NATURE_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TEST_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TTECH_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TSTAUT_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_CATEGORY_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_EVIDENCE_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_EVIDENCE_SS_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_CNTR_RISK_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_CNTR_RISK_SS_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_DTEVT_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_RESP_USER_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_ALLOW_REFER_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_CNGROUP_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_SUBGROUP_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TEST_ICON sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_ORIGIN_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_SS_OU_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_SS_CN_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_IS_MONITOR_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_IS_COMPLIENC_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_REG_SPECIFIC_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_RELEVANCE_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TPROC sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_INPUT sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_OUTPUT sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_EVT_DESC sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_SUBGROUP sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_RELEVANCE sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_ASSERTIONS_ID sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_ASSERTIONS sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_D sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CONTROL sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CONTROL_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CONTROL_D sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-TYPE sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-TYPE_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-SIG sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-SIG_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-AUTOM sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-AUTOM_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-FREQ sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-FREQ_T sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_SIG sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_IS_CONTROL sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_PURP sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_MATAR sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_AUTOM sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_FREQ sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_NATURE sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TEST sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TTECH sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TSTAUT sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_DTEVT sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_VALID_FROM sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_VALID_TO sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_TEST_PLAN sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_ALLOW_REFER sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_RESP_USER sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_CATEGORY sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_EVIDENCE sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_EVIDENCE_SS sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_CNTR_RISK sy-vline
WA_GRPC_DS_S_SUBPROCESS_CONTROLS_STR-CN_CNTR_RISK_SS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.