ABAP Select data from SAP table GRFNDMCP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRFNDMCP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRFNDMCP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRFNDMCP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRFNDMCP TYPE STANDARD TABLE OF GRFNDMCP,
      WA_GRFNDMCP TYPE GRFNDMCP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRFNDMCP> TYPE GRFNDMCP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRFNDMCP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRFNDMCP
  INTO TABLE IT_GRFNDMCP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRFNDMCP
*  INTO TABLE @DATA(IT_GRFNDMCP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRFNDMCP INDEX 1 INTO DATA(WA_GRFNDMCP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRFNDMCP ASSIGNING <GRFNDMCP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRFNDMCP>-MANDT = 1.
<GRFNDMCP>-SNAPSHOT_ID = 1.
<GRFNDMCP>-OBJECT_ID = 1.
<GRFNDMCP>-CP_GUID = 1.
<GRFNDMCP>-CP_PROCESSOR = 1.
ENDLOOP.

LOOP AT IT_GRFNDMCP INTO WA_GRFNDMCP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRFNDMCP-CP_CREA_USER, sy-vline,
WA_GRFNDMCP-CP_CREA_DATE, sy-vline,
WA_GRFNDMCP-CP_CREA_DATE_TM, sy-vline,
WA_GRFNDMCP-CP_CHANGED_ON, sy-vline,
WA_GRFNDMCP-CP_CHANGED_ON_TM, sy-vline,
WA_GRFNDMCP-CP_CLOSED_ON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRFNDMCP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRFNDMCP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRFNDMCP INTO WA_GRFNDMCP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRFNDMCP_STR,
MANDT TYPE STRING,
SNAPSHOT_ID TYPE STRING,
OBJECT_ID TYPE STRING,
CP_GUID TYPE STRING,
CP_PROCESSOR TYPE STRING,
CP_CREA_USER TYPE STRING,
CP_CREA_DATE TYPE STRING,
CP_CREA_DATE_TM TYPE STRING,
CP_CHANGED_ON TYPE STRING,
CP_CHANGED_ON_TM TYPE STRING,
CP_CLOSED_ON TYPE STRING,
CP_CLOSED_ON_TM TYPE STRING,
CP_START_DATE TYPE STRING,
CP_END_DATE TYPE STRING,
CP_STATUS TYPE STRING,
CP_OVERDUE TYPE STRING,
CP_RE TYPE STRING,
CP_CATEGORY TYPE STRING,
CP_RESP_USER TYPE STRING,
CP_CF_STATUS TYPE STRING,
CP_CF_TFRAME TYPE STRING,
CP_CF_YEAR TYPE STRING,
CP_VAL_USER TYPE STRING,
CP_VAL_DATE TYPE STRING,
CP_TF_BEGDA TYPE STRING,
CP_TF_ENDDA TYPE STRING,
CP_TFRAME TYPE STRING,
CP_TF_YEAR TYPE STRING,
CP_SURVEY_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRFNDMCP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRFNDMCP_STR-MANDT sy-vline
WA_GRFNDMCP_STR-SNAPSHOT_ID sy-vline
WA_GRFNDMCP_STR-OBJECT_ID sy-vline
WA_GRFNDMCP_STR-CP_GUID sy-vline
WA_GRFNDMCP_STR-CP_PROCESSOR sy-vline
WA_GRFNDMCP_STR-CP_CREA_USER sy-vline
WA_GRFNDMCP_STR-CP_CREA_DATE sy-vline
WA_GRFNDMCP_STR-CP_CREA_DATE_TM sy-vline
WA_GRFNDMCP_STR-CP_CHANGED_ON sy-vline
WA_GRFNDMCP_STR-CP_CHANGED_ON_TM sy-vline
WA_GRFNDMCP_STR-CP_CLOSED_ON sy-vline
WA_GRFNDMCP_STR-CP_CLOSED_ON_TM sy-vline
WA_GRFNDMCP_STR-CP_START_DATE sy-vline
WA_GRFNDMCP_STR-CP_END_DATE sy-vline
WA_GRFNDMCP_STR-CP_STATUS sy-vline
WA_GRFNDMCP_STR-CP_OVERDUE sy-vline
WA_GRFNDMCP_STR-CP_RE sy-vline
WA_GRFNDMCP_STR-CP_CATEGORY sy-vline
WA_GRFNDMCP_STR-CP_RESP_USER sy-vline
WA_GRFNDMCP_STR-CP_CF_STATUS sy-vline
WA_GRFNDMCP_STR-CP_CF_TFRAME sy-vline
WA_GRFNDMCP_STR-CP_CF_YEAR sy-vline
WA_GRFNDMCP_STR-CP_VAL_USER sy-vline
WA_GRFNDMCP_STR-CP_VAL_DATE sy-vline
WA_GRFNDMCP_STR-CP_TF_BEGDA sy-vline
WA_GRFNDMCP_STR-CP_TF_ENDDA sy-vline
WA_GRFNDMCP_STR-CP_TFRAME sy-vline
WA_GRFNDMCP_STR-CP_TF_YEAR sy-vline
WA_GRFNDMCP_STR-CP_SURVEY_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.