ABAP Select data from SAP table GRAC_S_FFLOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRAC_S_FFLOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRAC_S_FFLOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GRAC_S_FFLOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GRAC_S_FFLOG TYPE STANDARD TABLE OF GRAC_S_FFLOG,
      WA_GRAC_S_FFLOG TYPE GRAC_S_FFLOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GRAC_S_FFLOG> TYPE GRAC_S_FFLOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GRAC_S_FFLOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GRAC_S_FFLOG
  INTO TABLE IT_GRAC_S_FFLOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GRAC_S_FFLOG
*  INTO TABLE @DATA(IT_GRAC_S_FFLOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GRAC_S_FFLOG INDEX 1 INTO DATA(WA_GRAC_S_FFLOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GRAC_S_FFLOG ASSIGNING <GRAC_S_FFLOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRAC_S_FFLOG>-FFLOG_ID = 1.
<GRAC_S_FFLOG>-FFOBJECT = 1.
<GRAC_S_FFLOG>-CONNECTOR = 1.
<GRAC_S_FFLOG>-FF_USER = 1.
<GRAC_S_FFLOG>-LOGON_TIME = 1.
ENDLOOP.

LOOP AT IT_GRAC_S_FFLOG INTO WA_GRAC_S_FFLOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GRAC_S_FFLOG-REASON_CODE, sy-vline,
WA_GRAC_S_FFLOG-REASON_TEXT, sy-vline,
WA_GRAC_S_FFLOG-TEXT_OBJECT, sy-vline,
WA_GRAC_S_FFLOG-FF_OWNER, sy-vline,
WA_GRAC_S_FFLOG-LOGON_ID, sy-vline,
WA_GRAC_S_FFLOG-WF_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRAC_S_FFLOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRAC_S_FFLOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRAC_S_FFLOG INTO WA_GRAC_S_FFLOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRAC_S_FFLOG_STR,
FFLOG_ID TYPE STRING,
FFOBJECT TYPE STRING,
CONNECTOR TYPE STRING,
FF_USER TYPE STRING,
LOGON_TIME TYPE STRING,
REASON_CODE TYPE STRING,
REASON_TEXT TYPE STRING,
TEXT_OBJECT TYPE STRING,
FF_OWNER TYPE STRING,
LOGON_ID TYPE STRING,
WF_ID TYPE STRING,
WORKFLOW_SENT TYPE STRING,
REASON_CODE_DESCN TYPE STRING,
ACTIVITY_DESCN TYPE STRING,
ADDNL_ACTIVITY_DESCN TYPE STRING,
ITEM_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRAC_S_FFLOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRAC_S_FFLOG_STR-FFLOG_ID sy-vline
WA_GRAC_S_FFLOG_STR-FFOBJECT sy-vline
WA_GRAC_S_FFLOG_STR-CONNECTOR sy-vline
WA_GRAC_S_FFLOG_STR-FF_USER sy-vline
WA_GRAC_S_FFLOG_STR-LOGON_TIME sy-vline
WA_GRAC_S_FFLOG_STR-REASON_CODE sy-vline
WA_GRAC_S_FFLOG_STR-REASON_TEXT sy-vline
WA_GRAC_S_FFLOG_STR-TEXT_OBJECT sy-vline
WA_GRAC_S_FFLOG_STR-FF_OWNER sy-vline
WA_GRAC_S_FFLOG_STR-LOGON_ID sy-vline
WA_GRAC_S_FFLOG_STR-WF_ID sy-vline
WA_GRAC_S_FFLOG_STR-WORKFLOW_SENT sy-vline
WA_GRAC_S_FFLOG_STR-REASON_CODE_DESCN sy-vline
WA_GRAC_S_FFLOG_STR-ACTIVITY_DESCN sy-vline
WA_GRAC_S_FFLOG_STR-ADDNL_ACTIVITY_DESCN sy-vline
WA_GRAC_S_FFLOG_STR-ITEM_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.