ABAP Select data from SAP table GLO_FAA_S_ANX16_COMMON into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GLO_FAA_S_ANX16_COMMON table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GLO_FAA_S_ANX16_COMMON. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GLO_FAA_S_ANX16_COMMON table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GLO_FAA_S_ANX16_COMMON TYPE STANDARD TABLE OF GLO_FAA_S_ANX16_COMMON,
      WA_GLO_FAA_S_ANX16_COMMON TYPE GLO_FAA_S_ANX16_COMMON,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GLO_FAA_S_ANX16_COMMON> TYPE GLO_FAA_S_ANX16_COMMON.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GLO_FAA_S_ANX16_COMMON.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GLO_FAA_S_ANX16_COMMON
  INTO TABLE IT_GLO_FAA_S_ANX16_COMMON.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GLO_FAA_S_ANX16_COMMON
*  INTO TABLE @DATA(IT_GLO_FAA_S_ANX16_COMMON2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GLO_FAA_S_ANX16_COMMON INDEX 1 INTO DATA(WA_GLO_FAA_S_ANX16_COMMON2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GLO_FAA_S_ANX16_COMMON ASSIGNING <GLO_FAA_S_ANX16_COMMON>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GLO_FAA_S_ANX16_COMMON>-BUKRS = 1.
<GLO_FAA_S_ANX16_COMMON>-ANLN1 = 1.
<GLO_FAA_S_ANX16_COMMON>-ANLN2 = 1.
<GLO_FAA_S_ANX16_COMMON>-TXT50 = 1.
<GLO_FAA_S_ANX16_COMMON>-TXA50 = 1.
ENDLOOP.

LOOP AT IT_GLO_FAA_S_ANX16_COMMON INTO WA_GLO_FAA_S_ANX16_COMMON.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GLO_FAA_S_ANX16_COMMON-ANLKL, sy-vline,
WA_GLO_FAA_S_ANX16_COMMON-TXK50, sy-vline,
WA_GLO_FAA_S_ANX16_COMMON-WAERS, sy-vline,
WA_GLO_FAA_S_ANX16_COMMON-ZUJHR, sy-vline,
WA_GLO_FAA_S_ANX16_COMMON-ZUPER, sy-vline,
WA_GLO_FAA_S_ANX16_COMMON-ZUGDT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GLO_FAA_S_ANX16_COMMON you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GLO_FAA_S_ANX16_COMMON TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GLO_FAA_S_ANX16_COMMON INTO WA_GLO_FAA_S_ANX16_COMMON. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ANLN1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_COMMON-ANLN1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_COMMON-ANLN1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_COMMON-ANLN2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_COMMON-ANLN2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLKL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_COMMON-ANLKL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_COMMON-ANLKL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field ZUJHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_COMMON-ZUJHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_COMMON-ZUJHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GLO_FAA_S_ANX16_COMMON_STR,
BUKRS TYPE STRING,
ANLN1 TYPE STRING,
ANLN2 TYPE STRING,
TXT50 TYPE STRING,
TXA50 TYPE STRING,
ANLKL TYPE STRING,
TXK50 TYPE STRING,
WAERS TYPE STRING,
ZUJHR TYPE STRING,
ZUPER TYPE STRING,
ZUGDT TYPE STRING,END OF T_EKKO_STR. DATA: WA_GLO_FAA_S_ANX16_COMMON_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-BUKRS sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-ANLN1 sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-ANLN2 sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-TXT50 sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-TXA50 sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-ANLKL sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-TXK50 sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-WAERS sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-ZUJHR sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-ZUPER sy-vline
WA_GLO_FAA_S_ANX16_COMMON_STR-ZUGDT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.