ABAP Select data from SAP table GLO_FAA_S_ANX16_8_OM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GLO_FAA_S_ANX16_8_OM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GLO_FAA_S_ANX16_8_OM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GLO_FAA_S_ANX16_8_OM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GLO_FAA_S_ANX16_8_OM TYPE STANDARD TABLE OF GLO_FAA_S_ANX16_8_OM,
      WA_GLO_FAA_S_ANX16_8_OM TYPE GLO_FAA_S_ANX16_8_OM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GLO_FAA_S_ANX16_8_OM> TYPE GLO_FAA_S_ANX16_8_OM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GLO_FAA_S_ANX16_8_OM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GLO_FAA_S_ANX16_8_OM
  INTO TABLE IT_GLO_FAA_S_ANX16_8_OM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GLO_FAA_S_ANX16_8_OM
*  INTO TABLE @DATA(IT_GLO_FAA_S_ANX16_8_OM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GLO_FAA_S_ANX16_8_OM INDEX 1 INTO DATA(WA_GLO_FAA_S_ANX16_8_OM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GLO_FAA_S_ANX16_8_OM ASSIGNING <GLO_FAA_S_ANX16_8_OM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GLO_FAA_S_ANX16_8_OM>-BUKRS = 1.
<GLO_FAA_S_ANX16_8_OM>-ANLN1 = 1.
<GLO_FAA_S_ANX16_8_OM>-ANLN2 = 1.
<GLO_FAA_S_ANX16_8_OM>-TXT50 = 1.
<GLO_FAA_S_ANX16_8_OM>-TXA50 = 1.
ENDLOOP.

LOOP AT IT_GLO_FAA_S_ANX16_8_OM INTO WA_GLO_FAA_S_ANX16_8_OM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GLO_FAA_S_ANX16_8_OM-ANLKL, sy-vline,
WA_GLO_FAA_S_ANX16_8_OM-TXK50, sy-vline,
WA_GLO_FAA_S_ANX16_8_OM-WAERS, sy-vline,
WA_GLO_FAA_S_ANX16_8_OM-ZUJHR, sy-vline,
WA_GLO_FAA_S_ANX16_8_OM-ZUPER, sy-vline,
WA_GLO_FAA_S_ANX16_8_OM-ZUGDT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GLO_FAA_S_ANX16_8_OM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GLO_FAA_S_ANX16_8_OM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GLO_FAA_S_ANX16_8_OM INTO WA_GLO_FAA_S_ANX16_8_OM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ANLN1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-ANLN1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-ANLN1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-ANLN2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-ANLN2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLKL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-ANLKL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-ANLKL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field ZUJHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-ZUJHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-ZUJHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field GJE_KANSW CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-GJE_KANSW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-GJE_KANSW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEP_LIM_NT CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-DEP_LIM_NT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-DEP_LIM_NT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEP_AMT CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-DEP_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-DEP_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEP_SHORT CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-DEP_SHORT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-DEP_SHORT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEP_EXCESS CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-DEP_EXCESS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-DEP_EXCESS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEP_DEF_EX_PR CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-DEP_DEF_EX_PR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-DEP_DEF_EX_PR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field ADM_WO CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-ADM_WO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-ADM_WO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC132, internal->external for field DEP_EX_CO CALL FUNCTION 'CONVERSION_EXIT_AC132_OUTPUT' EXPORTING input = WA_GLO_FAA_S_ANX16_8_OM-DEP_EX_CO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLO_FAA_S_ANX16_8_OM-DEP_EX_CO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GLO_FAA_S_ANX16_8_OM_STR,
BUKRS TYPE STRING,
ANLN1 TYPE STRING,
ANLN2 TYPE STRING,
TXT50 TYPE STRING,
TXA50 TYPE STRING,
ANLKL TYPE STRING,
TXK50 TYPE STRING,
WAERS TYPE STRING,
ZUJHR TYPE STRING,
ZUPER TYPE STRING,
ZUGDT TYPE STRING,
BUP_ST TYPE STRING,
BUP_ST_J_E TYPE STRING,
BUP_ST_J TYPE STRING,
GJE_KANSW TYPE STRING,
DEP_MNTHS_CRNTTRM TYPE STRING,
DEP_LIM_NT TYPE STRING,
DEP_AMT TYPE STRING,
DEP_SHORT TYPE STRING,
DEP_EXCESS TYPE STRING,
DEP_DEF_EX_PR TYPE STRING,
ADM_WO TYPE STRING,
DEP_EX_CO TYPE STRING,
BUP_EN_J_ET TYPE STRING,
BUP_ST_J_EN TYPE STRING,END OF T_EKKO_STR. DATA: WA_GLO_FAA_S_ANX16_8_OM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-BUKRS sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-ANLN1 sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-ANLN2 sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-TXT50 sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-TXA50 sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-ANLKL sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-TXK50 sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-WAERS sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-ZUJHR sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-ZUPER sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-ZUGDT sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-BUP_ST sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-BUP_ST_J_E sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-BUP_ST_J sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-GJE_KANSW sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-DEP_MNTHS_CRNTTRM sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-DEP_LIM_NT sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-DEP_AMT sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-DEP_SHORT sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-DEP_EXCESS sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-DEP_DEF_EX_PR sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-ADM_WO sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-DEP_EX_CO sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-BUP_EN_J_ET sy-vline
WA_GLO_FAA_S_ANX16_8_OM_STR-BUP_ST_J_EN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.