ABAP Select data from SAP table GLE_MCA_STR_T030H_SEQNO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GLE_MCA_STR_T030H_SEQNO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GLE_MCA_STR_T030H_SEQNO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GLE_MCA_STR_T030H_SEQNO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GLE_MCA_STR_T030H_SEQNO TYPE STANDARD TABLE OF GLE_MCA_STR_T030H_SEQNO,
      WA_GLE_MCA_STR_T030H_SEQNO TYPE GLE_MCA_STR_T030H_SEQNO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GLE_MCA_STR_T030H_SEQNO> TYPE GLE_MCA_STR_T030H_SEQNO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GLE_MCA_STR_T030H_SEQNO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GLE_MCA_STR_T030H_SEQNO
  INTO TABLE IT_GLE_MCA_STR_T030H_SEQNO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GLE_MCA_STR_T030H_SEQNO
*  INTO TABLE @DATA(IT_GLE_MCA_STR_T030H_SEQNO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GLE_MCA_STR_T030H_SEQNO INDEX 1 INTO DATA(WA_GLE_MCA_STR_T030H_SEQNO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GLE_MCA_STR_T030H_SEQNO ASSIGNING <GLE_MCA_STR_T030H_SEQNO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GLE_MCA_STR_T030H_SEQNO>-SEQNO = 1.
<GLE_MCA_STR_T030H_SEQNO>-MANDT = 1.
<GLE_MCA_STR_T030H_SEQNO>-KTOPL = 1.
<GLE_MCA_STR_T030H_SEQNO>-PRCCAT = 1.
<GLE_MCA_STR_T030H_SEQNO>-PRCTYPE = 1.
ENDLOOP.

LOOP AT IT_GLE_MCA_STR_T030H_SEQNO INTO WA_GLE_MCA_STR_T030H_SEQNO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GLE_MCA_STR_T030H_SEQNO-SAKNR, sy-vline,
WA_GLE_MCA_STR_T030H_SEQNO-WAERS, sy-vline,
WA_GLE_MCA_STR_T030H_SEQNO-CURTP, sy-vline,
WA_GLE_MCA_STR_T030H_SEQNO-POSTYPE, sy-vline,
WA_GLE_MCA_STR_T030H_SEQNO-LEDENV, sy-vline,
WA_GLE_MCA_STR_T030H_SEQNO-RLDNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GLE_MCA_STR_T030H_SEQNO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GLE_MCA_STR_T030H_SEQNO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GLE_MCA_STR_T030H_SEQNO INTO WA_GLE_MCA_STR_T030H_SEQNO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SAKNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-SAKNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-SAKNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-HKONT1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-HKONT1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCNTR1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-RCNTR1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-RCNTR1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-HKONT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-HKONT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCNTR2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-RCNTR2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-RCNTR2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HKONT3 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-HKONT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-HKONT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCNTR3 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLE_MCA_STR_T030H_SEQNO-RCNTR3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLE_MCA_STR_T030H_SEQNO-RCNTR3.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GLE_MCA_STR_T030H_SEQNO_STR,
SEQNO TYPE STRING,
MANDT TYPE STRING,
KTOPL TYPE STRING,
PRCCAT TYPE STRING,
PRCTYPE TYPE STRING,
SAKNR TYPE STRING,
WAERS TYPE STRING,
CURTP TYPE STRING,
POSTYPE TYPE STRING,
LEDENV TYPE STRING,
RLDNR TYPE STRING,
RBUKRS TYPE STRING,
HKONT1 TYPE STRING,
RCNTR1 TYPE STRING,
HKONT2 TYPE STRING,
RCNTR2 TYPE STRING,
HKONT3 TYPE STRING,
RCNTR3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_GLE_MCA_STR_T030H_SEQNO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-SEQNO sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-MANDT sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-KTOPL sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-PRCCAT sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-PRCTYPE sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-SAKNR sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-WAERS sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-CURTP sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-POSTYPE sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-LEDENV sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-RLDNR sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-RBUKRS sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-HKONT1 sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-RCNTR1 sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-HKONT2 sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-RCNTR2 sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-HKONT3 sy-vline
WA_GLE_MCA_STR_T030H_SEQNO_STR-RCNTR3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.