ABAP Select data from SAP table GHO_S_SP_NETOBJ_INIT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GHO_S_SP_NETOBJ_INIT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GHO_S_SP_NETOBJ_INIT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GHO_S_SP_NETOBJ_INIT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GHO_S_SP_NETOBJ_INIT TYPE STANDARD TABLE OF GHO_S_SP_NETOBJ_INIT,
      WA_GHO_S_SP_NETOBJ_INIT TYPE GHO_S_SP_NETOBJ_INIT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GHO_S_SP_NETOBJ_INIT> TYPE GHO_S_SP_NETOBJ_INIT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GHO_S_SP_NETOBJ_INIT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GHO_S_SP_NETOBJ_INIT
  INTO TABLE IT_GHO_S_SP_NETOBJ_INIT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GHO_S_SP_NETOBJ_INIT
*  INTO TABLE @DATA(IT_GHO_S_SP_NETOBJ_INIT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GHO_S_SP_NETOBJ_INIT INDEX 1 INTO DATA(WA_GHO_S_SP_NETOBJ_INIT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GHO_S_SP_NETOBJ_INIT ASSIGNING <GHO_S_SP_NETOBJ_INIT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GHO_S_SP_NETOBJ_INIT>-GHO_NETOBJ_TYPE = 1.
<GHO_S_SP_NETOBJ_INIT>-TPLNR = 1.
<GHO_S_SP_NETOBJ_INIT>-GHO_NETOBJ_ID = 1.
<GHO_S_SP_NETOBJ_INIT>-GHO_NETOBJ_ID_CHG = 1.
<GHO_S_SP_NETOBJ_INIT>-TPLKZ = 1.
ENDLOOP.

LOOP AT IT_GHO_S_SP_NETOBJ_INIT INTO WA_GHO_S_SP_NETOBJ_INIT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GHO_S_SP_NETOBJ_INIT-TXT_TPLKZ, sy-vline,
WA_GHO_S_SP_NETOBJ_INIT-EDITM, sy-vline,
WA_GHO_S_SP_NETOBJ_INIT-FLTYP, sy-vline,
WA_GHO_S_SP_NETOBJ_INIT-GHO_VALID_FROM, sy-vline,
WA_GHO_S_SP_NETOBJ_INIT-GHO_VALID_TO, sy-vline,
WA_GHO_S_SP_NETOBJ_INIT-GHO_WC_REF_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GHO_S_SP_NETOBJ_INIT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GHO_S_SP_NETOBJ_INIT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GHO_S_SP_NETOBJ_INIT INTO WA_GHO_S_SP_NETOBJ_INIT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field TPLNR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_CHG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_CHG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_CHG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_WC_REF_ID CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_WC_REF_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_WC_REF_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_WELLCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_WELLCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_WELLCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_WCCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_WCCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_WCCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_MTRCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_MTRCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_MTRCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_TANKCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_TANKCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_TANKCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_TBCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_TBCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_TBCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_SEPCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_SEPCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_SEPCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_DEHCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_DEHCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_DEHCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_HTCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_HTCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_HTCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_CMPCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_CMPCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_CMPCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_PNCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_PNCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_PNCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_PMPCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_PMPCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_PMPCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_PIPECHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_PIPECHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_PIPECHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field GHO_NETOBJ_ID_MFOLDCHNG CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_MFOLDCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_MFOLDCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_WELL CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_WELL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_WELL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_WC CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_WC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_WC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_MTR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_MTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_MTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_TANK CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_TANK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_TANK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_SEP CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_SEP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_SEP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_DEH CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_DEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_DEH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_HT CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_HT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_HT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_CMP CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_CMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_CMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_PN CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_PN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_PN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_PMP CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_PMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_PMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_TB CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_TB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_TB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_FLAR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_FLAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_FLAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_PIPE CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_PIPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_PIPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_MFOLD CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_MFOLD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_MFOLD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field GHO_NETOBJ_ID_GENCHNG CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_GENCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_GENCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_GEN CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_GEN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_GEN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field GHO_NETOBJ_ID_CLSTRCHNG CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_CLSTRCHNG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-GHO_NETOBJ_ID_CLSTRCHNG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field TPLCP_CLSTR CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_SP_NETOBJ_INIT-TPLCP_CLSTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_SP_NETOBJ_INIT-TPLCP_CLSTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GHO_S_SP_NETOBJ_INIT_STR,
GHO_NETOBJ_TYPE TYPE STRING,
TPLNR TYPE STRING,
GHO_NETOBJ_ID TYPE STRING,
GHO_NETOBJ_ID_CHG TYPE STRING,
TPLKZ TYPE STRING,
TXT_TPLKZ TYPE STRING,
EDITM TYPE STRING,
FLTYP TYPE STRING,
GHO_VALID_FROM TYPE STRING,
GHO_VALID_TO TYPE STRING,
GHO_WC_REF_ID TYPE STRING,
ALKEY TYPE STRING,
ALTXT TYPE STRING,
STUFM TYPE STRING,
TPLCP TYPE STRING,
GHO_NETOBJ_ID_WELLCHNG TYPE STRING,
GHO_NETOBJ_ID_WCCHNG TYPE STRING,
GHO_NETOBJ_ID_MTRCHNG TYPE STRING,
GHO_NETOBJ_ID_TANKCHNG TYPE STRING,
GHO_NETOBJ_ID_TBCHNG TYPE STRING,
GHO_NETOBJ_ID_SEPCHNG TYPE STRING,
GHO_NETOBJ_ID_DEHCHNG TYPE STRING,
GHO_NETOBJ_ID_HTCHNG TYPE STRING,
GHO_NETOBJ_ID_CMPCHNG TYPE STRING,
GHO_NETOBJ_ID_PNCHNG TYPE STRING,
GHO_NETOBJ_ID_PMPCHNG TYPE STRING,
GHO_NETOBJ_ID_PIPECHNG TYPE STRING,
GHO_NETOBJ_ID_MFOLDCHNG TYPE STRING,
TPLCP_WELL TYPE STRING,
TPLCP_WC TYPE STRING,
TPLCP_MTR TYPE STRING,
TPLCP_TANK TYPE STRING,
TPLCP_SEP TYPE STRING,
TPLCP_DEH TYPE STRING,
TPLCP_HT TYPE STRING,
TPLCP_CMP TYPE STRING,
TPLCP_PN TYPE STRING,
TPLCP_PMP TYPE STRING,
TPLCP_TB TYPE STRING,
TPLCP_FLAR TYPE STRING,
TPLCP_PIPE TYPE STRING,
TPLCP_MFOLD TYPE STRING,
GHO_NETOBJ_ID_GENCHNG TYPE STRING,
TPLCP_GEN TYPE STRING,
GHO_NETOBJ_ID_CLSTRCHNG TYPE STRING,
TPLCP_CLSTR TYPE STRING,
GHO_CLSTR_TYPE TYPE STRING,
GHO_GEN_TYPE TYPE STRING,
GHO_CREATE_FROM_FLOC TYPE STRING,END OF T_EKKO_STR. DATA: WA_GHO_S_SP_NETOBJ_INIT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_TYPE sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLNR sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_CHG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLKZ sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TXT_TPLKZ sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-EDITM sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-FLTYP sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_VALID_FROM sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_VALID_TO sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_WC_REF_ID sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-ALKEY sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-ALTXT sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-STUFM sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_WELLCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_WCCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_MTRCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_TANKCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_TBCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_SEPCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_DEHCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_HTCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_CMPCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_PNCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_PMPCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_PIPECHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_MFOLDCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_WELL sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_WC sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_MTR sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_TANK sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_SEP sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_DEH sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_HT sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_CMP sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_PN sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_PMP sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_TB sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_FLAR sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_PIPE sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_MFOLD sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_GENCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_GEN sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_NETOBJ_ID_CLSTRCHNG sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-TPLCP_CLSTR sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_CLSTR_TYPE sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_GEN_TYPE sy-vline
WA_GHO_S_SP_NETOBJ_INIT_STR-GHO_CREATE_FROM_FLOC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.