ABAP Select data from SAP table GHO_S_MP_MEAS_RDG_DET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GHO_S_MP_MEAS_RDG_DET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GHO_S_MP_MEAS_RDG_DET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GHO_S_MP_MEAS_RDG_DET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GHO_S_MP_MEAS_RDG_DET TYPE STANDARD TABLE OF GHO_S_MP_MEAS_RDG_DET,
      WA_GHO_S_MP_MEAS_RDG_DET TYPE GHO_S_MP_MEAS_RDG_DET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GHO_S_MP_MEAS_RDG_DET> TYPE GHO_S_MP_MEAS_RDG_DET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GHO_S_MP_MEAS_RDG_DET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GHO_S_MP_MEAS_RDG_DET
  INTO TABLE IT_GHO_S_MP_MEAS_RDG_DET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GHO_S_MP_MEAS_RDG_DET
*  INTO TABLE @DATA(IT_GHO_S_MP_MEAS_RDG_DET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GHO_S_MP_MEAS_RDG_DET INDEX 1 INTO DATA(WA_GHO_S_MP_MEAS_RDG_DET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GHO_S_MP_MEAS_RDG_DET ASSIGNING <GHO_S_MP_MEAS_RDG_DET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GHO_S_MP_MEAS_RDG_DET>-GHO_NET_ID = 1.
<GHO_S_MP_MEAS_RDG_DET>-GHO_FROM_DATE = 1.
<GHO_S_MP_MEAS_RDG_DET>-GHO_TO_DATE = 1.
<GHO_S_MP_MEAS_RDG_DET>-GHO_OBJ_TYPE = 1.
<GHO_S_MP_MEAS_RDG_DET>-GHO_NODE_ID = 1.
ENDLOOP.

LOOP AT IT_GHO_S_MP_MEAS_RDG_DET INTO WA_GHO_S_MP_MEAS_RDG_DET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GHO_S_MP_MEAS_RDG_DET-GHO_NET_OBJ_ID, sy-vline,
WA_GHO_S_MP_MEAS_RDG_DET-GHO_NET_OBJ_TYPE, sy-vline,
WA_GHO_S_MP_MEAS_RDG_DET-GHO_FREQUENCY, sy-vline,
WA_GHO_S_MP_MEAS_RDG_DET-GHO_OBJ_ID, sy-vline,
WA_GHO_S_MP_MEAS_RDG_DET-GHO_MEAS_FREQ, sy-vline,
WA_GHO_S_MP_MEAS_RDG_DET-MEDIUM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GHO_S_MP_MEAS_RDG_DET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GHO_S_MP_MEAS_RDG_DET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GHO_S_MP_MEAS_RDG_DET INTO WA_GHO_S_MP_MEAS_RDG_DET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field GHO_NET_ID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-GHO_NET_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-GHO_NET_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field GHO_NODE_ID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-GHO_NODE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-GHO_NODE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field GHO_NET_OBJ_ID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-GHO_NET_OBJ_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-GHO_NET_OBJ_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field GHO_OBJ_ID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-GHO_OBJ_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-GHO_OBJ_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ALLOC_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-ALLOC_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-ALLOC_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MEASMNT_POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-MEASMNT_POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-MEASMNT_POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field ORIGN_MP CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-ORIGN_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-ORIGN_MP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_PROD_NETWORK CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-TO_PROD_NETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-TO_PROD_NETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_NETWORK_OBJ CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-TO_NETWORK_OBJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-TO_NETWORK_OBJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field ORIGINATING_MP CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_MP_MEAS_RDG_DET-ORIGINATING_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_MEAS_RDG_DET-ORIGINATING_MP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GHO_S_MP_MEAS_RDG_DET_STR,
GHO_NET_ID TYPE STRING,
GHO_FROM_DATE TYPE STRING,
GHO_TO_DATE TYPE STRING,
GHO_OBJ_TYPE TYPE STRING,
GHO_NODE_ID TYPE STRING,
GHO_NET_OBJ_ID TYPE STRING,
GHO_NET_OBJ_TYPE TYPE STRING,
GHO_FREQUENCY TYPE STRING,
GHO_OBJ_ID TYPE STRING,
GHO_MEAS_FREQ TYPE STRING,
MEDIUM TYPE STRING,
GHO_QTY_TYPE TYPE STRING,
GHO_QTY_TYPE_DESCR TYPE STRING,
ALLOC_MAT TYPE STRING,
ALLOC_MAT_DESC TYPE STRING,
GHO_MEAS_DATE TYPE STRING,
GHO_MEAS_TIME TYPE STRING,
BUS_KEY TYPE STRING,
ALLOC_TYPE TYPE STRING,
MEASMNT_POINT TYPE STRING,
GHO_METER_TYPE TYPE STRING,
GHO_MEAS_CAT_ID TYPE STRING,
GHO_MEAS_CAT_ID_DESC TYPE STRING,
ORIGN_MP TYPE STRING,
TO_PROD_NETWORK TYPE STRING,
TO_NETOBJ_TYPE TYPE STRING,
TO_NETWORK_OBJ TYPE STRING,
LD_OIL_WO_RECOV TYPE STRING,
TRNSP_NO TYPE STRING,
TRNSP_REF_NO TYPE STRING,
TKT_NO TYPE STRING,
TRANSP_NAME TYPE STRING,
BUSINESS_STATUS TYPE STRING,
STATUS_TEXT TYPE STRING,
OBJECT_NUMBER TYPE STRING,
CHANGED_TST TYPE STRING,
AUTH_DIS TYPE STRING,
AUTH_INS TYPE STRING,
AUTH_DEL TYPE STRING,
AUTH_CHG TYPE STRING,
PPA_LOCK TYPE STRING,
PPA_REQUESTER_FLAG TYPE STRING,
REQUESTER TYPE STRING,
MANUAL_FLAG TYPE STRING,
ALERT_ID TYPE STRING,
QTY_CATEGORY TYPE STRING,
ORIGINATING_MP TYPE STRING,
MRH_INDICATOR TYPE STRING,END OF T_EKKO_STR. DATA: WA_GHO_S_MP_MEAS_RDG_DET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_NET_ID sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_FROM_DATE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_TO_DATE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_OBJ_TYPE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_NODE_ID sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_NET_OBJ_ID sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_NET_OBJ_TYPE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_FREQUENCY sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_OBJ_ID sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_MEAS_FREQ sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-MEDIUM sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_QTY_TYPE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_QTY_TYPE_DESCR sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-ALLOC_MAT sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-ALLOC_MAT_DESC sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_MEAS_DATE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_MEAS_TIME sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-BUS_KEY sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-ALLOC_TYPE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-MEASMNT_POINT sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_METER_TYPE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_MEAS_CAT_ID sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-GHO_MEAS_CAT_ID_DESC sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-ORIGN_MP sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-TO_PROD_NETWORK sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-TO_NETOBJ_TYPE sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-TO_NETWORK_OBJ sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-LD_OIL_WO_RECOV sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-TRNSP_NO sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-TRNSP_REF_NO sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-TKT_NO sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-TRANSP_NAME sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-BUSINESS_STATUS sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-STATUS_TEXT sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-OBJECT_NUMBER sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-CHANGED_TST sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-AUTH_DIS sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-AUTH_INS sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-AUTH_DEL sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-AUTH_CHG sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-PPA_LOCK sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-PPA_REQUESTER_FLAG sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-REQUESTER sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-MANUAL_FLAG sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-ALERT_ID sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-QTY_CATEGORY sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-ORIGINATING_MP sy-vline
WA_GHO_S_MP_MEAS_RDG_DET_STR-MRH_INDICATOR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.