ABAP Select data from SAP table GHO_S_MP_FDC_MC_MEAS_RAW_DET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GHO_S_MP_FDC_MC_MEAS_RAW_DET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GHO_S_MP_FDC_MC_MEAS_RAW_DET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GHO_S_MP_FDC_MC_MEAS_RAW_DET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GHO_S_MP_FDC_MC_MEAS_RAW_DET TYPE STANDARD TABLE OF GHO_S_MP_FDC_MC_MEAS_RAW_DET,
      WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET TYPE GHO_S_MP_FDC_MC_MEAS_RAW_DET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GHO_S_MP_FDC_MC_MEAS_RAW_DET> TYPE GHO_S_MP_FDC_MC_MEAS_RAW_DET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GHO_S_MP_FDC_MC_MEAS_RAW_DET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GHO_S_MP_FDC_MC_MEAS_RAW_DET
  INTO TABLE IT_GHO_S_MP_FDC_MC_MEAS_RAW_DET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GHO_S_MP_FDC_MC_MEAS_RAW_DET
*  INTO TABLE @DATA(IT_GHO_S_MP_FDC_MC_MEAS_RAW_DET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GHO_S_MP_FDC_MC_MEAS_RAW_DET INDEX 1 INTO DATA(WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GHO_S_MP_FDC_MC_MEAS_RAW_DET ASSIGNING <GHO_S_MP_FDC_MC_MEAS_RAW_DET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GHO_S_MP_FDC_MC_MEAS_RAW_DET>-GHO_NET_ID = 1.
<GHO_S_MP_FDC_MC_MEAS_RAW_DET>-GHO_FROM_DATE = 1.
<GHO_S_MP_FDC_MC_MEAS_RAW_DET>-GHO_TO_DATE = 1.
<GHO_S_MP_FDC_MC_MEAS_RAW_DET>-GHO_OBJ_TYPE = 1.
<GHO_S_MP_FDC_MC_MEAS_RAW_DET>-GHO_NODE_ID = 1.
ENDLOOP.

LOOP AT IT_GHO_S_MP_FDC_MC_MEAS_RAW_DET INTO WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-GHO_NET_OBJ_ID, sy-vline,
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-GHO_NET_OBJ_TYPE, sy-vline,
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-GHO_FREQUENCY, sy-vline,
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-MEDIUM, sy-vline,
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-GHO_RECORD_ORIGIN, sy-vline,
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-GHO_OBJ_ID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GHO_S_MP_FDC_MC_MEAS_RAW_DET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GHO_S_MP_FDC_MC_MEAS_RAW_DET INTO WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field ALLOCATION_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-ALLOCATION_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-ALLOCATION_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MEASMNT_POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-MEASMNT_POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-MEASMNT_POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UOM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-UOM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET-UOM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR,
GHO_NET_ID TYPE STRING,
GHO_FROM_DATE TYPE STRING,
GHO_TO_DATE TYPE STRING,
GHO_OBJ_TYPE TYPE STRING,
GHO_NODE_ID TYPE STRING,
GHO_NET_OBJ_ID TYPE STRING,
GHO_NET_OBJ_TYPE TYPE STRING,
GHO_FREQUENCY TYPE STRING,
MEDIUM TYPE STRING,
GHO_RECORD_ORIGIN TYPE STRING,
GHO_OBJ_ID TYPE STRING,
GHO_MEAS_FREQ TYPE STRING,
GHO_QTY_TYPE TYPE STRING,
GHO_QTY_TYPE_DESCR TYPE STRING,
ALLOCATION_MAT TYPE STRING,
GHO_MEAS_DATE TYPE STRING,
GHO_MEAS_TIME TYPE STRING,
BUS_KEY TYPE STRING,
ALLOC_TYPE TYPE STRING,
MEASMNT_POINT TYPE STRING,
GHO_MEAS_CAT_ID TYPE STRING,
MDC_PARAMETER TYPE STRING,
REF_NETWORK_ID TYPE STRING,
REF_NODE_ID TYPE STRING,
MDC_VALUE TYPE STRING,
UOM TYPE STRING,
ITEM TYPE STRING,
LOW TYPE STRING,
HIGH TYPE STRING,
OPERATOR TYPE STRING,
MDC_DATATYPE TYPE STRING,
MDCLEN TYPE STRING,
MDC_PARAMETER_TXT TYPE STRING,
MDC_DECIMAL TYPE STRING,
MDC_VISIBILITY TYPE STRING,
MDC_MANDATORY TYPE STRING,
MANUAL_FLAG TYPE STRING,
FCHARDESC TYPE STRING,END OF T_EKKO_STR. DATA: WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_NET_ID sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_FROM_DATE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_TO_DATE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_OBJ_TYPE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_NODE_ID sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_NET_OBJ_ID sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_NET_OBJ_TYPE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_FREQUENCY sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MEDIUM sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_RECORD_ORIGIN sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_OBJ_ID sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_MEAS_FREQ sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_QTY_TYPE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_QTY_TYPE_DESCR sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-ALLOCATION_MAT sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_MEAS_DATE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_MEAS_TIME sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-BUS_KEY sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-ALLOC_TYPE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MEASMNT_POINT sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-GHO_MEAS_CAT_ID sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDC_PARAMETER sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-REF_NETWORK_ID sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-REF_NODE_ID sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDC_VALUE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-UOM sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-ITEM sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-LOW sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-HIGH sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-OPERATOR sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDC_DATATYPE sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDCLEN sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDC_PARAMETER_TXT sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDC_DECIMAL sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDC_VISIBILITY sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MDC_MANDATORY sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-MANUAL_FLAG sy-vline
WA_GHO_S_MP_FDC_MC_MEAS_RAW_DET_STR-FCHARDESC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.