ABAP Select data from SAP table GHO_S_IMRG_STD_H_UI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GHO_S_IMRG_STD_H_UI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GHO_S_IMRG_STD_H_UI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GHO_S_IMRG_STD_H_UI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GHO_S_IMRG_STD_H_UI TYPE STANDARD TABLE OF GHO_S_IMRG_STD_H_UI,
      WA_GHO_S_IMRG_STD_H_UI TYPE GHO_S_IMRG_STD_H_UI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GHO_S_IMRG_STD_H_UI> TYPE GHO_S_IMRG_STD_H_UI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GHO_S_IMRG_STD_H_UI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GHO_S_IMRG_STD_H_UI
  INTO TABLE IT_GHO_S_IMRG_STD_H_UI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GHO_S_IMRG_STD_H_UI
*  INTO TABLE @DATA(IT_GHO_S_IMRG_STD_H_UI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GHO_S_IMRG_STD_H_UI INDEX 1 INTO DATA(WA_GHO_S_IMRG_STD_H_UI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GHO_S_IMRG_STD_H_UI ASSIGNING <GHO_S_IMRG_STD_H_UI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GHO_S_IMRG_STD_H_UI>-MANDT = 1.
<GHO_S_IMRG_STD_H_UI>-NETID = 1.
<GHO_S_IMRG_STD_H_UI>-NETOBJ = 1.
<GHO_S_IMRG_STD_H_UI>-ALLOC_MATERIAL = 1.
<GHO_S_IMRG_STD_H_UI>-QUANTITY_TYPE = 1.
ENDLOOP.

LOOP AT IT_GHO_S_IMRG_STD_H_UI INTO WA_GHO_S_IMRG_STD_H_UI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GHO_S_IMRG_STD_H_UI-PROD_TIMESTAMP, sy-vline,
WA_GHO_S_IMRG_STD_H_UI-ALLOC_TYPE, sy-vline,
WA_GHO_S_IMRG_STD_H_UI-FREQUENCY, sy-vline,
WA_GHO_S_IMRG_STD_H_UI-GHO_MEAS_CAT_ID, sy-vline,
WA_GHO_S_IMRG_STD_H_UI-BUS_KEY, sy-vline,
WA_GHO_S_IMRG_STD_H_UI-MDOCM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GHO_S_IMRG_STD_H_UI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GHO_S_IMRG_STD_H_UI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GHO_S_IMRG_STD_H_UI INTO WA_GHO_S_IMRG_STD_H_UI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TPLNR, internal->external for field NETID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-NETID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-NETID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field NETOBJ CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-NETOBJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-NETOBJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field ALLOC_MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-ALLOC_MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-ALLOC_MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MDOCM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-MDOCM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-MDOCM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field REF_NETWORK_ID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-REF_NETWORK_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-REF_NETWORK_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TPLNR, internal->external for field REF_NODE_ID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-REF_NODE_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-REF_NODE_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_PROD_NETWORK CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-TO_PROD_NETWORK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-TO_PROD_NETWORK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field TO_NETWORK_OBJ CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-TO_NETWORK_OBJ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-TO_NETWORK_OBJ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRNSP_NO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-TRNSP_NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-TRNSP_NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GHONO, internal->external for field ORIGINATING_MP CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_IMRG_STD_H_UI-ORIGINATING_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_IMRG_STD_H_UI-ORIGINATING_MP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GHO_S_IMRG_STD_H_UI_STR,
MANDT TYPE STRING,
NETID TYPE STRING,
NETOBJ TYPE STRING,
ALLOC_MATERIAL TYPE STRING,
QUANTITY_TYPE TYPE STRING,
PROD_TIMESTAMP TYPE STRING,
ALLOC_TYPE TYPE STRING,
FREQUENCY TYPE STRING,
GHO_MEAS_CAT_ID TYPE STRING,
BUS_KEY TYPE STRING,
MDOCM TYPE STRING,
MRH_SUB_FLAG TYPE STRING,
MANUAL_FLAG TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_TST TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_TST TYPE STRING,
REF_NETWORK_ID TYPE STRING,
REF_NODE_ID TYPE STRING,
BUSINESS_STATUS TYPE STRING,
STATUS_OBJECT_NUMBER TYPE STRING,
TO_PROD_NETWORK TYPE STRING,
TO_NETOBJ_TYPE TYPE STRING,
TO_NETWORK_OBJ TYPE STRING,
LD_OIL_WO_RECOV TYPE STRING,
TRNSP_NO TYPE STRING,
TRNSP_REF_NO TYPE STRING,
TKT_NO TYPE STRING,
TRANSP_NAME TYPE STRING,
ORIGINATING_MP TYPE STRING,END OF T_EKKO_STR. DATA: WA_GHO_S_IMRG_STD_H_UI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-MANDT sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-NETID sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-NETOBJ sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-ALLOC_MATERIAL sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-QUANTITY_TYPE sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-PROD_TIMESTAMP sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-ALLOC_TYPE sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-FREQUENCY sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-GHO_MEAS_CAT_ID sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-BUS_KEY sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-MDOCM sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-MRH_SUB_FLAG sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-MANUAL_FLAG sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-CREATED_BY sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-CREATED_TST sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-CHANGED_BY sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-CHANGED_TST sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-REF_NETWORK_ID sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-REF_NODE_ID sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-BUSINESS_STATUS sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-STATUS_OBJECT_NUMBER sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-TO_PROD_NETWORK sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-TO_NETOBJ_TYPE sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-TO_NETWORK_OBJ sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-LD_OIL_WO_RECOV sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-TRNSP_NO sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-TRNSP_REF_NO sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-TKT_NO sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-TRANSP_NAME sy-vline
WA_GHO_S_IMRG_STD_H_UI_STR-ORIGINATING_MP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.