ABAP Select data from SAP table FWOT_0100 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FWOT_0100 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FWOT_0100. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FWOT_0100 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FWOT_0100 TYPE STANDARD TABLE OF FWOT_0100,
      WA_FWOT_0100 TYPE FWOT_0100,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FWOT_0100> TYPE FWOT_0100.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FWOT_0100.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FWOT_0100
  INTO TABLE IT_FWOT_0100.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FWOT_0100
*  INTO TABLE @DATA(IT_FWOT_01002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FWOT_0100 INDEX 1 INTO DATA(WA_FWOT_01002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FWOT_0100 ASSIGNING <FWOT_0100>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FWOT_0100>-DDISPO = 1.
<FWOT_0100>-SBEWART = 1.
<FWOT_0100>-XBEWART = 1.
<FWOT_0100>-SBEWZITI = 1.
<FWOT_0100>-SCWHR = 1.
ENDLOOP.

LOOP AT IT_FWOT_0100 INTO WA_FWOT_0100.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FWOT_0100-BCWHR, sy-vline,
WA_FWOT_0100-ASTUECK, sy-vline,
WA_FWOT_0100-BBASIS, sy-vline,
WA_FWOT_0100-DVALUT, sy-vline,
WA_FWOT_0100-DFAELL, sy-vline,
WA_FWOT_0100-DBESTAND, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FWOT_0100 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FWOT_0100 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FWOT_0100 INTO WA_FWOT_0100. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FWOT_0100_STR,
DDISPO TYPE STRING,
SBEWART TYPE STRING,
XBEWART TYPE STRING,
SBEWZITI TYPE STRING,
SCWHR TYPE STRING,
BCWHR TYPE STRING,
ASTUECK TYPE STRING,
BBASIS TYPE STRING,
DVALUT TYPE STRING,
DFAELL TYPE STRING,
DBESTAND TYPE STRING,
SBWHR TYPE STRING,
BBWHR TYPE STRING,
SHWHR TYPE STRING,
BHWHR TYPE STRING,
REFINDEX TYPE STRING,
MARK TYPE STRING,END OF T_EKKO_STR. DATA: WA_FWOT_0100_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FWOT_0100_STR-DDISPO sy-vline
WA_FWOT_0100_STR-SBEWART sy-vline
WA_FWOT_0100_STR-XBEWART sy-vline
WA_FWOT_0100_STR-SBEWZITI sy-vline
WA_FWOT_0100_STR-SCWHR sy-vline
WA_FWOT_0100_STR-BCWHR sy-vline
WA_FWOT_0100_STR-ASTUECK sy-vline
WA_FWOT_0100_STR-BBASIS sy-vline
WA_FWOT_0100_STR-DVALUT sy-vline
WA_FWOT_0100_STR-DFAELL sy-vline
WA_FWOT_0100_STR-DBESTAND sy-vline
WA_FWOT_0100_STR-SBWHR sy-vline
WA_FWOT_0100_STR-BBWHR sy-vline
WA_FWOT_0100_STR-SHWHR sy-vline
WA_FWOT_0100_STR-BHWHR sy-vline
WA_FWOT_0100_STR-REFINDEX sy-vline
WA_FWOT_0100_STR-MARK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.