ABAP Select data from SAP table FWEL_DRV_EKKO_EKPO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FWEL_DRV_EKKO_EKPO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FWEL_DRV_EKKO_EKPO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FWEL_DRV_EKKO_EKPO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FWEL_DRV_EKKO_EKPO TYPE STANDARD TABLE OF FWEL_DRV_EKKO_EKPO,
      WA_FWEL_DRV_EKKO_EKPO TYPE FWEL_DRV_EKKO_EKPO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FWEL_DRV_EKKO_EKPO> TYPE FWEL_DRV_EKKO_EKPO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FWEL_DRV_EKKO_EKPO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FWEL_DRV_EKKO_EKPO
  INTO TABLE IT_FWEL_DRV_EKKO_EKPO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FWEL_DRV_EKKO_EKPO
*  INTO TABLE @DATA(IT_FWEL_DRV_EKKO_EKPO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FWEL_DRV_EKKO_EKPO INDEX 1 INTO DATA(WA_FWEL_DRV_EKKO_EKPO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FWEL_DRV_EKKO_EKPO ASSIGNING <FWEL_DRV_EKKO_EKPO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FWEL_DRV_EKKO_EKPO>-BSART = 1.
<FWEL_DRV_EKKO_EKPO>-BEDAT = 1.
<FWEL_DRV_EKKO_EKPO>-STATU = 1.
<FWEL_DRV_EKKO_EKPO>-LOG_SY = 1.
<FWEL_DRV_EKKO_EKPO>-KONNR = 1.
ENDLOOP.

LOOP AT IT_FWEL_DRV_EKKO_EKPO INTO WA_FWEL_DRV_EKKO_EKPO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FWEL_DRV_EKKO_EKPO-KTPNR, sy-vline,
WA_FWEL_DRV_EKKO_EKPO-AEDAT, sy-vline,
WA_FWEL_DRV_EKKO_EKPO-KDATB, sy-vline,
WA_FWEL_DRV_EKKO_EKPO-KDATE, sy-vline,
WA_FWEL_DRV_EKKO_EKPO-GEBER, sy-vline,
WA_FWEL_DRV_EKKO_EKPO-FISTL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FWEL_DRV_EKKO_EKPO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FWEL_DRV_EKKO_EKPO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FWEL_DRV_EKKO_EKPO INTO WA_FWEL_DRV_EKKO_EKPO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field LOG_SY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FWEL_DRV_EKKO_EKPO-LOG_SY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FWEL_DRV_EKKO_EKPO-LOG_SY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KONNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FWEL_DRV_EKKO_EKPO-KONNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FWEL_DRV_EKKO_EKPO-KONNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIS, internal->external for field FIPOS CALL FUNCTION 'CONVERSION_EXIT_FMCIS_OUTPUT' EXPORTING input = WA_FWEL_DRV_EKKO_EKPO-FIPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FWEL_DRV_EKKO_EKPO-FIPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FWEL_DRV_EKKO_EKPO-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FWEL_DRV_EKKO_EKPO-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FWEL_DRV_EKKO_EKPO_STR,
BSART TYPE STRING,
BEDAT TYPE STRING,
STATU TYPE STRING,
LOG_SY TYPE STRING,
KONNR TYPE STRING,
KTPNR TYPE STRING,
AEDAT TYPE STRING,
KDATB TYPE STRING,
KDATE TYPE STRING,
GEBER TYPE STRING,
FISTL TYPE STRING,
FIPOS TYPE STRING,
GRANT_NBR TYPE STRING,
FKBER TYPE STRING,
BUDGET_PD TYPE STRING,END OF T_EKKO_STR. DATA: WA_FWEL_DRV_EKKO_EKPO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-BSART sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-BEDAT sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-STATU sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-LOG_SY sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-KONNR sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-KTPNR sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-AEDAT sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-KDATB sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-KDATE sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-GEBER sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-FISTL sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-FIPOS sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-GRANT_NBR sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-FKBER sy-vline
WA_FWEL_DRV_EKKO_EKPO_STR-BUDGET_PD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.