ABAP Select data from SAP table FUNOCM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FUNOCM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FUNOCM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FUNOCM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FUNOCM TYPE STANDARD TABLE OF FUNOCM,
      WA_FUNOCM TYPE FUNOCM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FUNOCM> TYPE FUNOCM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FUNOCM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FUNOCM
  INTO TABLE IT_FUNOCM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FUNOCM
*  INTO TABLE @DATA(IT_FUNOCM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FUNOCM INDEX 1 INTO DATA(WA_FUNOCM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FUNOCM ASSIGNING <FUNOCM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FUNOCM>-MANDT = 1.
<FUNOCM>-FUNCT = 1.
<FUNOCM>-OBART = 1.
<FUNOCM>-OBJNR = 1.
<FUNOCM>-COUNTER = 1.
ENDLOOP.

LOOP AT IT_FUNOCM INTO WA_FUNOCM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FUNOCM-GROUP_NUM, sy-vline,
WA_FUNOCM-MATNR, sy-vline,
WA_FUNOCM-WERKS, sy-vline,
WA_FUNOCM-REF_FUNCT, sy-vline,
WA_FUNOCM-REF_OBART, sy-vline,
WA_FUNOCM-REF_OBJNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FUNOCM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FUNOCM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FUNOCM INTO WA_FUNOCM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_FUNOCM-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FUNOCM-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FUNOCM-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FUNOCM-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FUNOCM-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FUNOCM-AENNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FUNOCM_STR,
MANDT TYPE STRING,
FUNCT TYPE STRING,
OBART TYPE STRING,
OBJNR TYPE STRING,
COUNTER TYPE STRING,
GROUP_NUM TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
REF_FUNCT TYPE STRING,
REF_OBART TYPE STRING,
REF_OBJNR TYPE STRING,
VERS_X TYPE STRING,
COMP_X TYPE STRING,
CHECK_X TYPE STRING,
TRANS_X TYPE STRING,
EXPAND_FL TYPE STRING,
AUFNR TYPE STRING,
VSNMR TYPE STRING,
COMPNUM TYPE STRING,
USNAM TYPE STRING,
CPUTM TYPE STRING,
CPUDT TYPE STRING,
ABGL_X TYPE STRING,
DATUV_OLD TYPE STRING,
REF_COUNTER TYPE STRING,
OCMPF TYPE STRING,
MAXCONFTYP TYPE STRING,
LOGNUMBER TYPE STRING,
TSTMPS TYPE STRING,
ERROR_COUNTER TYPE STRING,
AENNR TYPE STRING,
LOG_HANDLE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FUNOCM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FUNOCM_STR-MANDT sy-vline
WA_FUNOCM_STR-FUNCT sy-vline
WA_FUNOCM_STR-OBART sy-vline
WA_FUNOCM_STR-OBJNR sy-vline
WA_FUNOCM_STR-COUNTER sy-vline
WA_FUNOCM_STR-GROUP_NUM sy-vline
WA_FUNOCM_STR-MATNR sy-vline
WA_FUNOCM_STR-WERKS sy-vline
WA_FUNOCM_STR-REF_FUNCT sy-vline
WA_FUNOCM_STR-REF_OBART sy-vline
WA_FUNOCM_STR-REF_OBJNR sy-vline
WA_FUNOCM_STR-VERS_X sy-vline
WA_FUNOCM_STR-COMP_X sy-vline
WA_FUNOCM_STR-CHECK_X sy-vline
WA_FUNOCM_STR-TRANS_X sy-vline
WA_FUNOCM_STR-EXPAND_FL sy-vline
WA_FUNOCM_STR-AUFNR sy-vline
WA_FUNOCM_STR-VSNMR sy-vline
WA_FUNOCM_STR-COMPNUM sy-vline
WA_FUNOCM_STR-USNAM sy-vline
WA_FUNOCM_STR-CPUTM sy-vline
WA_FUNOCM_STR-CPUDT sy-vline
WA_FUNOCM_STR-ABGL_X sy-vline
WA_FUNOCM_STR-DATUV_OLD sy-vline
WA_FUNOCM_STR-REF_COUNTER sy-vline
WA_FUNOCM_STR-OCMPF sy-vline
WA_FUNOCM_STR-MAXCONFTYP sy-vline
WA_FUNOCM_STR-LOGNUMBER sy-vline
WA_FUNOCM_STR-TSTMPS sy-vline
WA_FUNOCM_STR-ERROR_COUNTER sy-vline
WA_FUNOCM_STR-AENNR sy-vline
WA_FUNOCM_STR-LOG_HANDLE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.