ABAP Select data from SAP table FTI_LDB_TR_HM_HEDGE_ID into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FTI_LDB_TR_HM_HEDGE_ID table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FTI_LDB_TR_HM_HEDGE_ID. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FTI_LDB_TR_HM_HEDGE_ID table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FTI_LDB_TR_HM_HEDGE_ID TYPE STANDARD TABLE OF FTI_LDB_TR_HM_HEDGE_ID,
      WA_FTI_LDB_TR_HM_HEDGE_ID TYPE FTI_LDB_TR_HM_HEDGE_ID,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FTI_LDB_TR_HM_HEDGE_ID> TYPE FTI_LDB_TR_HM_HEDGE_ID.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FTI_LDB_TR_HM_HEDGE_ID.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FTI_LDB_TR_HM_HEDGE_ID
  INTO TABLE IT_FTI_LDB_TR_HM_HEDGE_ID.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FTI_LDB_TR_HM_HEDGE_ID
*  INTO TABLE @DATA(IT_FTI_LDB_TR_HM_HEDGE_ID2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FTI_LDB_TR_HM_HEDGE_ID INDEX 1 INTO DATA(WA_FTI_LDB_TR_HM_HEDGE_ID2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FTI_LDB_TR_HM_HEDGE_ID ASSIGNING <FTI_LDB_TR_HM_HEDGE_ID>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FTI_LDB_TR_HM_HEDGE_ID>-BUKRS = 1.
<FTI_LDB_TR_HM_HEDGE_ID>-HEDGEPLAN_ID = 1.
<FTI_LDB_TR_HM_HEDGE_ID>-VALUATION_AREA = 1.
<FTI_LDB_TR_HM_HEDGE_ID>-HEDGE_ID = 1.
<FTI_LDB_TR_HM_HEDGE_ID>-CRUSER = 1.
ENDLOOP.

LOOP AT IT_FTI_LDB_TR_HM_HEDGE_ID INTO WA_FTI_LDB_TR_HM_HEDGE_ID.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FTI_LDB_TR_HM_HEDGE_ID-UPUSER, sy-vline,
WA_FTI_LDB_TR_HM_HEDGE_ID-H_CR_DATE, sy-vline,
WA_FTI_LDB_TR_HM_HEDGE_ID-H_CH_DATE, sy-vline,
WA_FTI_LDB_TR_HM_HEDGE_ID-HEDGE_CAT, sy-vline,
WA_FTI_LDB_TR_HM_HEDGE_ID-REF_EXPOSURE_ID, sy-vline,
WA_FTI_LDB_TR_HM_HEDGE_ID-TARGET_RATIO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FTI_LDB_TR_HM_HEDGE_ID you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FTI_LDB_TR_HM_HEDGE_ID TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FTI_LDB_TR_HM_HEDGE_ID INTO WA_FTI_LDB_TR_HM_HEDGE_ID. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HEDGEPLAN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FTI_LDB_TR_HM_HEDGE_ID-HEDGEPLAN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FTI_LDB_TR_HM_HEDGE_ID-HEDGEPLAN_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_OF_MEASURE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FTI_LDB_TR_HM_HEDGE_ID-UNIT_OF_MEASURE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FTI_LDB_TR_HM_HEDGE_ID-UNIT_OF_MEASURE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FTI_LDB_TR_HM_HEDGE_ID_STR,
BUKRS TYPE STRING,
HEDGEPLAN_ID TYPE STRING,
VALUATION_AREA TYPE STRING,
HEDGE_ID TYPE STRING,
CRUSER TYPE STRING,
UPUSER TYPE STRING,
H_CR_DATE TYPE STRING,
H_CH_DATE TYPE STRING,
HEDGE_CAT TYPE STRING,
REF_EXPOSURE_ID TYPE STRING,
TARGET_RATIO TYPE STRING,
ACTUAL_RATIO TYPE STRING,
NOMINAL TYPE STRING,
CURRENCY TYPE STRING,
HEDGE_ID_ROLL TYPE STRING,
YTM TYPE STRING,
START_RECL_PL TYPE STRING,
END_RECL_PL TYPE STRING,
QUANTITY TYPE STRING,
UNIT_OF_MEASURE TYPE STRING,
COMMODITY_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_FTI_LDB_TR_HM_HEDGE_ID_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-BUKRS sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-HEDGEPLAN_ID sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-VALUATION_AREA sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-HEDGE_ID sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-CRUSER sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-UPUSER sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-H_CR_DATE sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-H_CH_DATE sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-HEDGE_CAT sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-REF_EXPOSURE_ID sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-TARGET_RATIO sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-ACTUAL_RATIO sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-NOMINAL sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-CURRENCY sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-HEDGE_ID_ROLL sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-YTM sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-START_RECL_PL sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-END_RECL_PL sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-QUANTITY sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-UNIT_OF_MEASURE sy-vline
WA_FTI_LDB_TR_HM_HEDGE_ID_STR-COMMODITY_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.