ABAP Select data from SAP table FTI_LDB_TR_HM_EFFECTIVE_VAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FTI_LDB_TR_HM_EFFECTIVE_VAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FTI_LDB_TR_HM_EFFECTIVE_VAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FTI_LDB_TR_HM_EFFECTIVE_VAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FTI_LDB_TR_HM_EFFECTIVE_VAL TYPE STANDARD TABLE OF FTI_LDB_TR_HM_EFFECTIVE_VAL,
      WA_FTI_LDB_TR_HM_EFFECTIVE_VAL TYPE FTI_LDB_TR_HM_EFFECTIVE_VAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FTI_LDB_TR_HM_EFFECTIVE_VAL> TYPE FTI_LDB_TR_HM_EFFECTIVE_VAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FTI_LDB_TR_HM_EFFECTIVE_VAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FTI_LDB_TR_HM_EFFECTIVE_VAL
  INTO TABLE IT_FTI_LDB_TR_HM_EFFECTIVE_VAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FTI_LDB_TR_HM_EFFECTIVE_VAL
*  INTO TABLE @DATA(IT_FTI_LDB_TR_HM_EFFECTIVE_VAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FTI_LDB_TR_HM_EFFECTIVE_VAL INDEX 1 INTO DATA(WA_FTI_LDB_TR_HM_EFFECTIVE_VAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FTI_LDB_TR_HM_EFFECTIVE_VAL ASSIGNING <FTI_LDB_TR_HM_EFFECTIVE_VAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FTI_LDB_TR_HM_EFFECTIVE_VAL>-BUKRS = 1.
<FTI_LDB_TR_HM_EFFECTIVE_VAL>-HEDGEPLAN_ID = 1.
<FTI_LDB_TR_HM_EFFECTIVE_VAL>-VALUATION_AREA = 1.
<FTI_LDB_TR_HM_EFFECTIVE_VAL>-HEDGE_ID = 1.
<FTI_LDB_TR_HM_EFFECTIVE_VAL>-HR_RFHA = 1.
ENDLOOP.

LOOP AT IT_FTI_LDB_TR_HM_EFFECTIVE_VAL INTO WA_FTI_LDB_TR_HM_EFFECTIVE_VAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-HR_VERSION, sy-vline,
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-VALUATION_DATE, sy-vline,
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-VALUATION_TIME, sy-vline,
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-CALC_TYPE, sy-vline,
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-CURRENCY_DELTA, sy-vline,
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-EFFECT_RATIO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FTI_LDB_TR_HM_EFFECTIVE_VAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FTI_LDB_TR_HM_EFFECTIVE_VAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FTI_LDB_TR_HM_EFFECTIVE_VAL INTO WA_FTI_LDB_TR_HM_EFFECTIVE_VAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HEDGEPLAN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-HEDGEPLAN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-HEDGEPLAN_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HR_RFHA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-HR_RFHA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FTI_LDB_TR_HM_EFFECTIVE_VAL-HR_RFHA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR,
BUKRS TYPE STRING,
HEDGEPLAN_ID TYPE STRING,
VALUATION_AREA TYPE STRING,
HEDGE_ID TYPE STRING,
HR_RFHA TYPE STRING,
HR_VERSION TYPE STRING,
VALUATION_DATE TYPE STRING,
VALUATION_TIME TYPE STRING,
CALC_TYPE TYPE STRING,
CURRENCY_DELTA TYPE STRING,
EFFECT_RATIO TYPE STRING,
REV_DATE TYPE STRING,
REV_TIME TYPE STRING,
CR_DATE TYPE STRING,
CRUSER TYPE STRING,
UPUSER TYPE STRING,
IS_REVERSED TYPE STRING,
RETRO TYPE STRING,
PROSPECT TYPE STRING,
INEFF_RECLASS TYPE STRING,
SHORTCUT TYPE STRING,
DELTA_DERIVATIVE TYPE STRING,
SUM_DELTA_DERIV TYPE STRING,
DELTA_HEDGE TYPE STRING,
SUM_DELTA_HEDGE TYPE STRING,
THRESHOLD TYPE STRING,
TRANS_SPEED TYPE STRING,
LOGUUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-BUKRS sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-HEDGEPLAN_ID sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-VALUATION_AREA sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-HEDGE_ID sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-HR_RFHA sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-HR_VERSION sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-VALUATION_DATE sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-VALUATION_TIME sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-CALC_TYPE sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-CURRENCY_DELTA sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-EFFECT_RATIO sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-REV_DATE sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-REV_TIME sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-CR_DATE sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-CRUSER sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-UPUSER sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-IS_REVERSED sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-RETRO sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-PROSPECT sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-INEFF_RECLASS sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-SHORTCUT sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-DELTA_DERIVATIVE sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-SUM_DELTA_DERIV sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-DELTA_HEDGE sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-SUM_DELTA_HEDGE sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-THRESHOLD sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-TRANS_SPEED sy-vline
WA_FTI_LDB_TR_HM_EFFECTIVE_VAL_STR-LOGUUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.