ABAP Select data from SAP table FSH_CCR_RESB_DISPLAY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FSH_CCR_RESB_DISPLAY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FSH_CCR_RESB_DISPLAY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FSH_CCR_RESB_DISPLAY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FSH_CCR_RESB_DISPLAY TYPE STANDARD TABLE OF FSH_CCR_RESB_DISPLAY,
      WA_FSH_CCR_RESB_DISPLAY TYPE FSH_CCR_RESB_DISPLAY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FSH_CCR_RESB_DISPLAY> TYPE FSH_CCR_RESB_DISPLAY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FSH_CCR_RESB_DISPLAY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FSH_CCR_RESB_DISPLAY
  INTO TABLE IT_FSH_CCR_RESB_DISPLAY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FSH_CCR_RESB_DISPLAY
*  INTO TABLE @DATA(IT_FSH_CCR_RESB_DISPLAY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FSH_CCR_RESB_DISPLAY INDEX 1 INTO DATA(WA_FSH_CCR_RESB_DISPLAY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FSH_CCR_RESB_DISPLAY ASSIGNING <FSH_CCR_RESB_DISPLAY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FSH_CCR_RESB_DISPLAY>-LIGHT = 1.
<FSH_CCR_RESB_DISPLAY>-RSNUM = 1.
<FSH_CCR_RESB_DISPLAY>-RSPOS = 1.
<FSH_CCR_RESB_DISPLAY>-EBELN = 1.
<FSH_CCR_RESB_DISPLAY>-EBELP = 1.
ENDLOOP.

LOOP AT IT_FSH_CCR_RESB_DISPLAY INTO WA_FSH_CCR_RESB_DISPLAY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FSH_CCR_RESB_DISPLAY-ETENR, sy-vline,
WA_FSH_CCR_RESB_DISPLAY-LIFNR, sy-vline,
WA_FSH_CCR_RESB_DISPLAY-MATNR, sy-vline,
WA_FSH_CCR_RESB_DISPLAY-WERKS, sy-vline,
WA_FSH_CCR_RESB_DISPLAY-LGORT, sy-vline,
WA_FSH_CCR_RESB_DISPLAY-BDART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FSH_CCR_RESB_DISPLAY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FSH_CCR_RESB_DISPLAY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FSH_CCR_RESB_DISPLAY INTO WA_FSH_CCR_RESB_DISPLAY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FSH_CCR_RESB_DISPLAY-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSH_CCR_RESB_DISPLAY-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FSH_CCR_RESB_DISPLAY-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSH_CCR_RESB_DISPLAY-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_FSH_CCR_RESB_DISPLAY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSH_CCR_RESB_DISPLAY-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FSH_CCR_RESB_DISPLAY_STR,
LIGHT TYPE STRING,
RSNUM TYPE STRING,
RSPOS TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
ETENR TYPE STRING,
LIFNR TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
BDART TYPE STRING,
BDTER TYPE STRING,
SBTER TYPE STRING,
BDMNG TYPE STRING,
RALLOC TYPE STRING,
FSH_RALLOC_QTY TYPE STRING,
WAMNG TYPE STRING,
DMENG TYPE STRING,
FMENG TYPE STRING,
HMENG TYPE STRING,
RMENG TYPE STRING,
SBDBS TYPE STRING,
REMARK TYPE STRING,END OF T_EKKO_STR. DATA: WA_FSH_CCR_RESB_DISPLAY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-LIGHT sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-RSNUM sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-RSPOS sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-EBELN sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-EBELP sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-ETENR sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-LIFNR sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-MATNR sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-WERKS sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-LGORT sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-BDART sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-BDTER sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-SBTER sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-BDMNG sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-RALLOC sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-FSH_RALLOC_QTY sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-WAMNG sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-DMENG sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-FMENG sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-HMENG sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-RMENG sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-SBDBS sy-vline
WA_FSH_CCR_RESB_DISPLAY_STR-REMARK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.