ABAP Select data from SAP table FRMLS_OTPT_RECO_PTR_DA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRMLS_OTPT_RECO_PTR_DA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRMLS_OTPT_RECO_PTR_DA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FRMLS_OTPT_RECO_PTR_DA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FRMLS_OTPT_RECO_PTR_DA TYPE STANDARD TABLE OF FRMLS_OTPT_RECO_PTR_DA,
      WA_FRMLS_OTPT_RECO_PTR_DA TYPE FRMLS_OTPT_RECO_PTR_DA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FRMLS_OTPT_RECO_PTR_DA> TYPE FRMLS_OTPT_RECO_PTR_DA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FRMLS_OTPT_RECO_PTR_DA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FRMLS_OTPT_RECO_PTR_DA
  INTO TABLE IT_FRMLS_OTPT_RECO_PTR_DA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FRMLS_OTPT_RECO_PTR_DA
*  INTO TABLE @DATA(IT_FRMLS_OTPT_RECO_PTR_DA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FRMLS_OTPT_RECO_PTR_DA INDEX 1 INTO DATA(WA_FRMLS_OTPT_RECO_PTR_DA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FRMLS_OTPT_RECO_PTR_DA ASSIGNING <FRMLS_OTPT_RECO_PTR_DA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRMLS_OTPT_RECO_PTR_DA>-ENGINE_KEY_COL = 1.
<FRMLS_OTPT_RECO_PTR_DA>-FRMLID = 1.
<FRMLS_OTPT_RECO_PTR_DA>-REM = 1.
<FRMLS_OTPT_RECO_PTR_DA>-REF_OBJ = 1.
<FRMLS_OTPT_RECO_PTR_DA>-ENGINE_KEY_ROW = 1.
ENDLOOP.

LOOP AT IT_FRMLS_OTPT_RECO_PTR_DA INTO WA_FRMLS_OTPT_RECO_PTR_DA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FRMLS_OTPT_RECO_PTR_DA-SUBID, sy-vline,
WA_FRMLS_OTPT_RECO_PTR_DA-IDENT, sy-vline,
WA_FRMLS_OTPT_RECO_PTR_DA-COMPCAT, sy-vline,
WA_FRMLS_OTPT_RECO_PTR_DA-PRECL, sy-vline,
WA_FRMLS_OTPT_RECO_PTR_DA-COMPLOW, sy-vline,
WA_FRMLS_OTPT_RECO_PTR_DA-PRECU, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRMLS_OTPT_RECO_PTR_DA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRMLS_OTPT_RECO_PTR_DA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRMLS_OTPT_RECO_PTR_DA INTO WA_FRMLS_OTPT_RECO_PTR_DA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CHRI2, internal->external for field FRMLID CALL FUNCTION 'CONVERSION_EXIT_CHRI2_OUTPUT' EXPORTING input = WA_FRMLS_OTPT_RECO_PTR_DA-FRMLID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_OTPT_RECO_PTR_DA-FRMLID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_FRMLS_OTPT_RECO_PTR_DA-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_OTPT_RECO_PTR_DA-SUBID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field COMPEXP CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRMLS_OTPT_RECO_PTR_DA-COMPEXP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_OTPT_RECO_PTR_DA-COMPEXP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRMLS_OTPT_RECO_PTR_DA_STR,
ENGINE_KEY_COL TYPE STRING,
FRMLID TYPE STRING,
REM TYPE STRING,
REF_OBJ TYPE STRING,
ENGINE_KEY_ROW TYPE STRING,
SUBID TYPE STRING,
IDENT TYPE STRING,
COMPCAT TYPE STRING,
PRECL TYPE STRING,
COMPLOW TYPE STRING,
PRECU TYPE STRING,
COMPUPP TYPE STRING,
COMPAVG TYPE STRING,
COMPEXP TYPE STRING,
COMPEXP6 TYPE STRING,
COMPEXPT TYPE STRING,
COMPEXPL TYPE STRING,
ORD TYPE STRING,
COMPEXCVAL TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRMLS_OTPT_RECO_PTR_DA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-ENGINE_KEY_COL sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-FRMLID sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-REM sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-REF_OBJ sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-ENGINE_KEY_ROW sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-SUBID sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-IDENT sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPCAT sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-PRECL sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPLOW sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-PRECU sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPUPP sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPAVG sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPEXP sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPEXP6 sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPEXPT sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPEXPL sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-ORD sy-vline
WA_FRMLS_OTPT_RECO_PTR_DA_STR-COMPEXCVAL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.