ABAP Select data from SAP table FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM TYPE STANDARD TABLE OF FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM,
      WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM TYPE FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM> TYPE FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM
  INTO TABLE IT_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM
*  INTO TABLE @DATA(IT_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM INDEX 1 INTO DATA(WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM ASSIGNING <FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM>-SUBID = 1.
<FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM>-SUBCAT = 1.
<FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM>-AUTHGRP = 1.
<FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM>-CRNAM = 1.
<FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM>-CRDAT = 1.
ENDLOOP.

LOOP AT IT_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM INTO WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-UPDNAM, sy-vline,
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-UPDDAT, sy-vline,
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-REM, sy-vline,
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-LOTSIZE_MIN, sy-vline,
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-LOTSIZE_MAX, sy-vline,
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-CONS_FLG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM INTO WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CHRI2, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_CHRI2_OUTPUT' EXPORTING input = WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-SUBID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BASE_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-BASE_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-BASE_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field INP_TGT_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-INP_TGT_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM-INP_TGT_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR,
SUBID TYPE STRING,
SUBCAT TYPE STRING,
AUTHGRP TYPE STRING,
CRNAM TYPE STRING,
CRDAT TYPE STRING,
UPDNAM TYPE STRING,
UPDDAT TYPE STRING,
REM TYPE STRING,
LOTSIZE_MIN TYPE STRING,
LOTSIZE_MAX TYPE STRING,
CONS_FLG TYPE STRING,
STEXT_CONSNAME TYPE STRING,
BASE_QUAN TYPE STRING,
BASE_UNIT TYPE STRING,
INP_TGT_QTY TYPE STRING,
INP_TGT_UNIT TYPE STRING,
LAYOUT TYPE STRING,
REAC_FLG TYPE STRING,
AGGR_FLG TYPE STRING,
EVAP_FLG TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-SUBID sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-SUBCAT sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-AUTHGRP sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-CRNAM sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-CRDAT sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-UPDNAM sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-UPDDAT sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-REM sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-LOTSIZE_MIN sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-LOTSIZE_MAX sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-CONS_FLG sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-STEXT_CONSNAME sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-BASE_QUAN sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-BASE_UNIT sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-INP_TGT_QTY sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-INP_TGT_UNIT sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-LAYOUT sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-REAC_FLG sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-AGGR_FLG sy-vline
WA_FRMLS_OTPT_4UDE_SIMPLE_HDR_FRM_STR-EVAP_FLG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.