ABAP Select data from SAP table FRMLS_IOT_CMP_DESCR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRMLS_IOT_CMP_DESCR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRMLS_IOT_CMP_DESCR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FRMLS_IOT_CMP_DESCR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FRMLS_IOT_CMP_DESCR TYPE STANDARD TABLE OF FRMLS_IOT_CMP_DESCR,
      WA_FRMLS_IOT_CMP_DESCR TYPE FRMLS_IOT_CMP_DESCR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FRMLS_IOT_CMP_DESCR> TYPE FRMLS_IOT_CMP_DESCR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FRMLS_IOT_CMP_DESCR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FRMLS_IOT_CMP_DESCR
  INTO TABLE IT_FRMLS_IOT_CMP_DESCR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FRMLS_IOT_CMP_DESCR
*  INTO TABLE @DATA(IT_FRMLS_IOT_CMP_DESCR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FRMLS_IOT_CMP_DESCR INDEX 1 INTO DATA(WA_FRMLS_IOT_CMP_DESCR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FRMLS_IOT_CMP_DESCR ASSIGNING <FRMLS_IOT_CMP_DESCR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRMLS_IOT_CMP_DESCR>-LINENO = 1.
<FRMLS_IOT_CMP_DESCR>-LINEMOD = 1.
<FRMLS_IOT_CMP_DESCR>-MANDT = 1.
<FRMLS_IOT_CMP_DESCR>-RECN = 1.
<FRMLS_IOT_CMP_DESCR>-RECNMST = 1.
ENDLOOP.

LOOP AT IT_FRMLS_IOT_CMP_DESCR INTO WA_FRMLS_IOT_CMP_DESCR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FRMLS_IOT_CMP_DESCR-RECNROOT, sy-vline,
WA_FRMLS_IOT_CMP_DESCR-RECNALGRP, sy-vline,
WA_FRMLS_IOT_CMP_DESCR-RECN_DATA, sy-vline,
WA_FRMLS_IOT_CMP_DESCR-SUBRECN, sy-vline,
WA_FRMLS_IOT_CMP_DESCR-ACTN, sy-vline,
WA_FRMLS_IOT_CMP_DESCR-MATNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRMLS_IOT_CMP_DESCR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRMLS_IOT_CMP_DESCR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRMLS_IOT_CMP_DESCR INTO WA_FRMLS_IOT_CMP_DESCR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SUBRECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-SUBRECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-SUBRECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-SUBID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT_CALC CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-UNIT_CALC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-UNIT_CALC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CHRI2, internal->external for field SUBID_RECNROOT CALL FUNCTION 'CONVERSION_EXIT_CHRI2_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-SUBID_RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-SUBID_RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field FRML_RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FRMLS_IOT_CMP_DESCR-FRML_RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_IOT_CMP_DESCR-FRML_RECNROOT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRMLS_IOT_CMP_DESCR_STR,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
RECNMST TYPE STRING,
RECNROOT TYPE STRING,
RECNALGRP TYPE STRING,
RECN_DATA TYPE STRING,
SUBRECN TYPE STRING,
ACTN TYPE STRING,
MATNR TYPE STRING,
SUBID TYPE STRING,
POSNR TYPE STRING,
ROLE TYPE STRING,
STD_ALT_FLG TYPE STRING,
FLG_ALT_EXIST TYPE STRING,
ALT_POSNR TYPE STRING,
PO_FLG TYPE STRING,
COMPTGT TYPE STRING,
COMPTGT_ERR_FLG TYPE STRING,
OPLOW TYPE STRING,
COMPLOW TYPE STRING,
OPUP TYPE STRING,
COMPUPP TYPE STRING,
UNIT TYPE STRING,
EXCVAL TYPE STRING,
ADDVAL TYPE STRING,
COMPTGT_FLT TYPE STRING,
COMPLOW_FLT TYPE STRING,
COMPUPP_FLT TYPE STRING,
OVR_FACTOR TYPE STRING,
DEF_EXPL_FLG TYPE STRING,
FLG_1_N_MAT TYPE STRING,
FLG_HAS_1_N_MAT TYPE STRING,
FLG_OUT TYPE STRING,
STREAM_FLG TYPE STRING,
STREAM_ID TYPE STRING,
LINE_MODE TYPE STRING,
COMPTGT_FLT_CALC TYPE STRING,
UNIT_CALC TYPE STRING,
EXCVAL_CALC TYPE STRING,
COMPTGT_FLT_SPEC TYPE STRING,
EXCVAL_SPEC TYPE STRING,
ITEM_DESCR_TEXT TYPE STRING,
ROLENAME TYPE STRING,
EXCVAL_TXT TYPE STRING,
IDENT TYPE STRING,
IDENT2 TYPE STRING,
MAKTX TYPE STRING,
__DUMMY TYPE STRING,
SUBID_RECNROOT TYPE STRING,
FRML_RECNROOT TYPE STRING,
IDENT_RECNROOT TYPE STRING,
UNIT_STEXT TYPE STRING,
LINE_MODE_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRMLS_IOT_CMP_DESCR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-LINENO sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-LINEMOD sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-MANDT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-RECN sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-RECNMST sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-RECNROOT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-RECNALGRP sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-RECN_DATA sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-SUBRECN sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-ACTN sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-MATNR sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-SUBID sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-POSNR sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-ROLE sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-STD_ALT_FLG sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-FLG_ALT_EXIST sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-ALT_POSNR sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-PO_FLG sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPTGT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPTGT_ERR_FLG sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-OPLOW sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPLOW sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-OPUP sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPUPP sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-UNIT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-EXCVAL sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-ADDVAL sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPTGT_FLT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPLOW_FLT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPUPP_FLT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-OVR_FACTOR sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-DEF_EXPL_FLG sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-FLG_1_N_MAT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-FLG_HAS_1_N_MAT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-FLG_OUT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-STREAM_FLG sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-STREAM_ID sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-LINE_MODE sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPTGT_FLT_CALC sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-UNIT_CALC sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-EXCVAL_CALC sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-COMPTGT_FLT_SPEC sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-EXCVAL_SPEC sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-ITEM_DESCR_TEXT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-ROLENAME sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-EXCVAL_TXT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-IDENT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-IDENT2 sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-MAKTX sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-__DUMMY sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-SUBID_RECNROOT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-FRML_RECNROOT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-IDENT_RECNROOT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-UNIT_STEXT sy-vline
WA_FRMLS_IOT_CMP_DESCR_STR-LINE_MODE_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.