ABAP Select data from SAP table FRE_MD_TPSRC_STY_41 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRE_MD_TPSRC_STY_41 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRE_MD_TPSRC_STY_41. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FRE_MD_TPSRC_STY_41 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FRE_MD_TPSRC_STY_41 TYPE STANDARD TABLE OF FRE_MD_TPSRC_STY_41,
      WA_FRE_MD_TPSRC_STY_41 TYPE FRE_MD_TPSRC_STY_41,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FRE_MD_TPSRC_STY_41> TYPE FRE_MD_TPSRC_STY_41.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FRE_MD_TPSRC_STY_41.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FRE_MD_TPSRC_STY_41
  INTO TABLE IT_FRE_MD_TPSRC_STY_41.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FRE_MD_TPSRC_STY_41
*  INTO TABLE @DATA(IT_FRE_MD_TPSRC_STY_412).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FRE_MD_TPSRC_STY_41 INDEX 1 INTO DATA(WA_FRE_MD_TPSRC_STY_412).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FRE_MD_TPSRC_STY_41 ASSIGNING <FRE_MD_TPSRC_STY_41>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRE_MD_TPSRC_STY_41>-MANDT = 1.
<FRE_MD_TPSRC_STY_41>-IBZQID = 1.
<FRE_MD_TPSRC_STY_41>-PSTATUS = 1.
<FRE_MD_TPSRC_STY_41>-FUNCTION = 1.
<FRE_MD_TPSRC_STY_41>-TDSRC = 1.
ENDLOOP.

LOOP AT IT_FRE_MD_TPSRC_STY_41 INTO WA_FRE_MD_TPSRC_STY_41.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FRE_MD_TPSRC_STY_41-EBELN, sy-vline,
WA_FRE_MD_TPSRC_STY_41-EBELP, sy-vline,
WA_FRE_MD_TPSRC_STY_41-EKORG, sy-vline,
WA_FRE_MD_TPSRC_STY_41-LOCNOTO, sy-vline,
WA_FRE_MD_TPSRC_STY_41-MATNR, sy-vline,
WA_FRE_MD_TPSRC_STY_41-LOCNOFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRE_MD_TPSRC_STY_41 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRE_MD_TPSRC_STY_41 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRE_MD_TPSRC_STY_41 INTO WA_FRE_MD_TPSRC_STY_41. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field BSTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRE_MD_TPSRC_STY_41-BSTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_TPSRC_STY_41-BSTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field PLIFZ CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_FRE_MD_TPSRC_STY_41-PLIFZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_TPSRC_STY_41-PLIFZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field TGIPRT CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_FRE_MD_TPSRC_STY_41-TGIPRT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_TPSRC_STY_41-TGIPRT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SENDER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FRE_MD_TPSRC_STY_41-SENDER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_TPSRC_STY_41-SENDER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRE_MD_TPSRC_STY_41_STR,
MANDT TYPE STRING,
IBZQID TYPE STRING,
PSTATUS TYPE STRING,
FUNCTION TYPE STRING,
TDSRC TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
EKORG TYPE STRING,
LOCNOTO TYPE STRING,
MATNR TYPE STRING,
LOCNOFR TYPE STRING,
CONSI TYPE STRING,
SUBCO TYPE STRING,
VALFR TYPE STRING,
VALFR_X TYPE STRING,
VALTO TYPE STRING,
VALTO_X TYPE STRING,
BZQ_ACTIVE TYPE STRING,
BZQ_ACTIVE_X TYPE STRING,
BSTME TYPE STRING,
BSTME_X TYPE STRING,
MEASGRSUP TYPE STRING,
MEASGRSUP_X TYPE STRING,
PLIFZ TYPE STRING,
PLIFZ_X TYPE STRING,
IDNLF TYPE STRING,
IDNLF_X TYPE STRING,
VARPUOM TYPE STRING,
VARPUOM_X TYPE STRING,
PRORD TYPE STRING,
PRORD_X TYPE STRING,
PROCYC TYPE STRING,
PROCYC_X TYPE STRING,
SLSNR TYPE STRING,
SLSNR_X TYPE STRING,
TGIPRT TYPE STRING,
TGIPRT_X TYPE STRING,
SPRIO TYPE STRING,
SPRIO_X TYPE STRING,
MINLS TYPE STRING,
MINLS_X TYPE STRING,
MAXLS TYPE STRING,
MAXLS_X TYPE STRING,
PROCESSING_METH TYPE STRING,
PROCESSING_METH_X TYPE STRING,
CREDATE TYPE STRING,
UPDDATE TYPE STRING,
SENDER TYPE STRING,
REF_ID TYPE STRING,
LOC_DYN TYPE STRING,
BSTME_ISO TYPE STRING,
BSTME_ISO_X TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRE_MD_TPSRC_STY_41_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MANDT sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-IBZQID sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PSTATUS sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-FUNCTION sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-TDSRC sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-EBELN sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-EBELP sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-EKORG sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-LOCNOTO sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MATNR sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-LOCNOFR sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-CONSI sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-SUBCO sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-VALFR sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-VALFR_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-VALTO sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-VALTO_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-BZQ_ACTIVE sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-BZQ_ACTIVE_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-BSTME sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-BSTME_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MEASGRSUP sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MEASGRSUP_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PLIFZ sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PLIFZ_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-IDNLF sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-IDNLF_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-VARPUOM sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-VARPUOM_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PRORD sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PRORD_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PROCYC sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PROCYC_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-SLSNR sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-SLSNR_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-TGIPRT sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-TGIPRT_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-SPRIO sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-SPRIO_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MINLS sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MINLS_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MAXLS sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-MAXLS_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PROCESSING_METH sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-PROCESSING_METH_X sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-CREDATE sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-UPDDATE sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-SENDER sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-REF_ID sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-LOC_DYN sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-BSTME_ISO sy-vline
WA_FRE_MD_TPSRC_STY_41_STR-BSTME_ISO_X sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.