ABAP Select data from SAP table FRE_MD_SUPPLY_SOURCE_DATA_STY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRE_MD_SUPPLY_SOURCE_DATA_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRE_MD_SUPPLY_SOURCE_DATA_STY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FRE_MD_SUPPLY_SOURCE_DATA_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FRE_MD_SUPPLY_SOURCE_DATA_STY TYPE STANDARD TABLE OF FRE_MD_SUPPLY_SOURCE_DATA_STY,
      WA_FRE_MD_SUPPLY_SOURCE_DATA_STY TYPE FRE_MD_SUPPLY_SOURCE_DATA_STY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FRE_MD_SUPPLY_SOURCE_DATA_STY> TYPE FRE_MD_SUPPLY_SOURCE_DATA_STY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FRE_MD_SUPPLY_SOURCE_DATA_STY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FRE_MD_SUPPLY_SOURCE_DATA_STY
  INTO TABLE IT_FRE_MD_SUPPLY_SOURCE_DATA_STY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FRE_MD_SUPPLY_SOURCE_DATA_STY
*  INTO TABLE @DATA(IT_FRE_MD_SUPPLY_SOURCE_DATA_STY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FRE_MD_SUPPLY_SOURCE_DATA_STY INDEX 1 INTO DATA(WA_FRE_MD_SUPPLY_SOURCE_DATA_STY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FRE_MD_SUPPLY_SOURCE_DATA_STY ASSIGNING <FRE_MD_SUPPLY_SOURCE_DATA_STY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRE_MD_SUPPLY_SOURCE_DATA_STY>-MATNR = 1.
<FRE_MD_SUPPLY_SOURCE_DATA_STY>-VENDOR = 1.
<FRE_MD_SUPPLY_SOURCE_DATA_STY>-SUPSITE = 1.
<FRE_MD_SUPPLY_SOURCE_DATA_STY>-RECSITE = 1.
<FRE_MD_SUPPLY_SOURCE_DATA_STY>-LOCNR = 1.
ENDLOOP.

LOOP AT IT_FRE_MD_SUPPLY_SOURCE_DATA_STY INTO WA_FRE_MD_SUPPLY_SOURCE_DATA_STY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-FUNCTION, sy-vline,
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-RECTYPE, sy-vline,
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-DELFROM, sy-vline,
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-DELTO, sy-vline,
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-INTLANE, sy-vline,
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-LANETYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRE_MD_SUPPLY_SOURCE_DATA_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRE_MD_SUPPLY_SOURCE_DATA_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRE_MD_SUPPLY_SOURCE_DATA_STY INTO WA_FRE_MD_SUPPLY_SOURCE_DATA_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VENDOR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-VENDOR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-VENDOR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-LOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-LOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-EBELN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ORDUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-ORDUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-ORDUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field RELTIME CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-RELTIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-RELTIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field GITIME CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-GITIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-GITIME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BPRME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-BPRME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_SUPPLY_SOURCE_DATA_STY-BPRME.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR,
MATNR TYPE STRING,
VENDOR TYPE STRING,
SUPSITE TYPE STRING,
RECSITE TYPE STRING,
LOCNR TYPE STRING,
FUNCTION TYPE STRING,
RECTYPE TYPE STRING,
DELFROM TYPE STRING,
DELTO TYPE STRING,
INTLANE TYPE STRING,
LANETYPE TYPE STRING,
VSRNR TYPE STRING,
MATKL TYPE STRING,
TDSRC TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
EKORG TYPE STRING,
PRIORITY TYPE STRING,
RPPLAN TYPE STRING,
PLIFZ TYPE STRING,
MINLOT TYPE STRING,
MAXLOT TYPE STRING,
ORDUNIT TYPE STRING,
IDVEND TYPE STRING,
VARORD TYPE STRING,
UOMGRP TYPE STRING,
RDPRF TYPE STRING,
NETPR TYPE STRING,
WAERS TYPE STRING,
CONSI TYPE STRING,
SUBCO TYPE STRING,
RSPRF TYPE STRING,
GRPLVL TYPE STRING,
PROCYC TYPE STRING,
RELTIME TYPE STRING,
GITIME TYPE STRING,
OPTIMHOR TYPE STRING,
SPRKZ TYPE STRING,
ORDUNIT_ISO TYPE STRING,
PURCHASE_GRP TYPE STRING,
PROCESSING_METH TYPE STRING,
SPECIAL_MARKER TYPE STRING,
PROCYC_TD_REL TYPE STRING,
KEY_TST TYPE STRING,
LOC_DYN TYPE STRING,
BPRME TYPE STRING,
PEINH TYPE STRING,
IBZQID TYPE STRING,
LANE_TD_ASSIGN TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-MATNR sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-VENDOR sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-SUPSITE sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-RECSITE sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-LOCNR sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-FUNCTION sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-RECTYPE sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-DELFROM sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-DELTO sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-INTLANE sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-LANETYPE sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-VSRNR sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-MATKL sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-TDSRC sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-EBELN sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-EBELP sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-EKORG sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-PRIORITY sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-RPPLAN sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-PLIFZ sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-MINLOT sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-MAXLOT sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-ORDUNIT sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-IDVEND sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-VARORD sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-UOMGRP sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-RDPRF sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-NETPR sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-WAERS sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-CONSI sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-SUBCO sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-RSPRF sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-GRPLVL sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-PROCYC sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-RELTIME sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-GITIME sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-OPTIMHOR sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-SPRKZ sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-ORDUNIT_ISO sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-PURCHASE_GRP sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-PROCESSING_METH sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-SPECIAL_MARKER sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-PROCYC_TD_REL sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-KEY_TST sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-LOC_DYN sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-BPRME sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-PEINH sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-IBZQID sy-vline
WA_FRE_MD_SUPPLY_SOURCE_DATA_STY_STR-LANE_TD_ASSIGN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.