ABAP Select data from SAP table FOTTDCL_POST_MOS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FOTTDCL_POST_MOS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FOTTDCL_POST_MOS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FOTTDCL_POST_MOS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FOTTDCL_POST_MOS TYPE STANDARD TABLE OF FOTTDCL_POST_MOS,
      WA_FOTTDCL_POST_MOS TYPE FOTTDCL_POST_MOS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FOTTDCL_POST_MOS> TYPE FOTTDCL_POST_MOS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FOTTDCL_POST_MOS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FOTTDCL_POST_MOS
  INTO TABLE IT_FOTTDCL_POST_MOS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FOTTDCL_POST_MOS
*  INTO TABLE @DATA(IT_FOTTDCL_POST_MOS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FOTTDCL_POST_MOS INDEX 1 INTO DATA(WA_FOTTDCL_POST_MOS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FOTTDCL_POST_MOS ASSIGNING <FOTTDCL_POST_MOS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FOTTDCL_POST_MOS>-MANDT = 1.
<FOTTDCL_POST_MOS>-DECL_TYPE = 1.
<FOTTDCL_POST_MOS>-TBUKRS = 1.
<FOTTDCL_POST_MOS>-DECL_CTRY = 1.
<FOTTDCL_POST_MOS>-DECL_YEAR = 1.
ENDLOOP.

LOOP AT IT_FOTTDCL_POST_MOS INTO WA_FOTTDCL_POST_MOS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FOTTDCL_POST_MOS-DECL_PER, sy-vline,
WA_FOTTDCL_POST_MOS-DECL_RUNID, sy-vline,
WA_FOTTDCL_POST_MOS-DECL_VERS, sy-vline,
WA_FOTTDCL_POST_MOS-LFDNR, sy-vline,
WA_FOTTDCL_POST_MOS-BUKRS, sy-vline,
WA_FOTTDCL_POST_MOS-HWAER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FOTTDCL_POST_MOS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FOTTDCL_POST_MOS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FOTTDCL_POST_MOS INTO WA_FOTTDCL_POST_MOS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field HWSTE CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-HWSTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-HWSTE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field H2STE CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-H2STE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-H2STE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field H3STE CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-H3STE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-H3STE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field DECL_TAX CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-DECL_TAX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-DECL_TAX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field DECL_AMT CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-DECL_AMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-DECL_AMT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field DECL_RND CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-DECL_RND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-DECL_RND.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU132, internal->external for field DECL_ZLHW CALL FUNCTION 'CONVERSION_EXIT_AU132_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-DECL_ZLHW IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-DECL_ZLHW.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-SEGMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PPRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-PPRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-PPRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PSEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-PSEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-PSEGMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-KOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-KOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NPLNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-NPLNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-NPLNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PS_PSP_PNR CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-PS_PSP_PNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-PS_PSP_PNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SERVICE_DOC_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-SERVICE_DOC_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-SERVICE_DOC_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIS, internal->external for field FIPOS CALL FUNCTION 'CONVERSION_EXIT_FMCIS_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-FIPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-FIPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BDGT_ACCOUNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-BDGT_ACCOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-BDGT_ACCOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIL, internal->external for field FMFG_OBJ_CL CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-FMFG_OBJ_CL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-FMFG_OBJ_CL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-ANLN1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-ANLN1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ANLN2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-ANLN2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-ANLN2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RE_ACCOUNT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-RE_ACCOUNT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-RE_ACCOUNT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PGRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FOTTDCL_POST_MOS-PGRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOTTDCL_POST_MOS-PGRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FOTTDCL_POST_MOS_STR,
MANDT TYPE STRING,
DECL_TYPE TYPE STRING,
TBUKRS TYPE STRING,
DECL_CTRY TYPE STRING,
DECL_YEAR TYPE STRING,
DECL_PER TYPE STRING,
DECL_RUNID TYPE STRING,
DECL_VERS TYPE STRING,
LFDNR TYPE STRING,
BUKRS TYPE STRING,
HWAER TYPE STRING,
HWAE2 TYPE STRING,
HWAE3 TYPE STRING,
HKONT TYPE STRING,
SHKZG TYPE STRING,
HWSTE TYPE STRING,
H2STE TYPE STRING,
H3STE TYPE STRING,
DECL_CURR TYPE STRING,
DECL_TAX TYPE STRING,
DECL_AMT TYPE STRING,
DECL_RND TYPE STRING,
DECL_ZLHW TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,
SEGMENT TYPE STRING,
PARGB TYPE STRING,
PPRCTR TYPE STRING,
PSEGMENT TYPE STRING,
AUFNR TYPE STRING,
IMKEY TYPE STRING,
DABRZ TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
KOSTL TYPE STRING,
KSTRG TYPE STRING,
NPLNR TYPE STRING,
APLZL TYPE STRING,
AUFPL TYPE STRING,
PAOBJNR TYPE STRING,
PS_PSP_PNR TYPE STRING,
SERVICE_DOC_TYPE TYPE STRING,
SERVICE_DOC_ID TYPE STRING,
SERVICE_DOC_ITEM_ID TYPE STRING,
FIPOS TYPE STRING,
FISTL TYPE STRING,
GEBER TYPE STRING,
BUDGET_PD TYPE STRING,
PGEBER TYPE STRING,
PBUDGET_PD TYPE STRING,
BDGT_ACCOUNT TYPE STRING,
BDGT_ACCOUNT_COCODE TYPE STRING,
FMCMMTSTR TYPE STRING,
FMFG_OBJ_CL TYPE STRING,
ANLN1 TYPE STRING,
ANLN2 TYPE STRING,
ANBWA TYPE STRING,
BZDAT TYPE STRING,
FKBER TYPE STRING,
DUMMY_INCL_EEW_COBL TYPE STRING,
RE_BUKRS TYPE STRING,
RE_ACCOUNT TYPE STRING,
GRANT_NBR TYPE STRING,
PGRANT_NBR TYPE STRING,
MEASURE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FOTTDCL_POST_MOS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FOTTDCL_POST_MOS_STR-MANDT sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_TYPE sy-vline
WA_FOTTDCL_POST_MOS_STR-TBUKRS sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_CTRY sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_YEAR sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_PER sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_RUNID sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_VERS sy-vline
WA_FOTTDCL_POST_MOS_STR-LFDNR sy-vline
WA_FOTTDCL_POST_MOS_STR-BUKRS sy-vline
WA_FOTTDCL_POST_MOS_STR-HWAER sy-vline
WA_FOTTDCL_POST_MOS_STR-HWAE2 sy-vline
WA_FOTTDCL_POST_MOS_STR-HWAE3 sy-vline
WA_FOTTDCL_POST_MOS_STR-HKONT sy-vline
WA_FOTTDCL_POST_MOS_STR-SHKZG sy-vline
WA_FOTTDCL_POST_MOS_STR-HWSTE sy-vline
WA_FOTTDCL_POST_MOS_STR-H2STE sy-vline
WA_FOTTDCL_POST_MOS_STR-H3STE sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_CURR sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_TAX sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_AMT sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_RND sy-vline
WA_FOTTDCL_POST_MOS_STR-DECL_ZLHW sy-vline
WA_FOTTDCL_POST_MOS_STR-GSBER sy-vline
WA_FOTTDCL_POST_MOS_STR-PRCTR sy-vline
WA_FOTTDCL_POST_MOS_STR-SEGMENT sy-vline
WA_FOTTDCL_POST_MOS_STR-PARGB sy-vline
WA_FOTTDCL_POST_MOS_STR-PPRCTR sy-vline
WA_FOTTDCL_POST_MOS_STR-PSEGMENT sy-vline
WA_FOTTDCL_POST_MOS_STR-AUFNR sy-vline
WA_FOTTDCL_POST_MOS_STR-IMKEY sy-vline
WA_FOTTDCL_POST_MOS_STR-DABRZ sy-vline
WA_FOTTDCL_POST_MOS_STR-KDAUF sy-vline
WA_FOTTDCL_POST_MOS_STR-KDPOS sy-vline
WA_FOTTDCL_POST_MOS_STR-KOSTL sy-vline
WA_FOTTDCL_POST_MOS_STR-KSTRG sy-vline
WA_FOTTDCL_POST_MOS_STR-NPLNR sy-vline
WA_FOTTDCL_POST_MOS_STR-APLZL sy-vline
WA_FOTTDCL_POST_MOS_STR-AUFPL sy-vline
WA_FOTTDCL_POST_MOS_STR-PAOBJNR sy-vline
WA_FOTTDCL_POST_MOS_STR-PS_PSP_PNR sy-vline
WA_FOTTDCL_POST_MOS_STR-SERVICE_DOC_TYPE sy-vline
WA_FOTTDCL_POST_MOS_STR-SERVICE_DOC_ID sy-vline
WA_FOTTDCL_POST_MOS_STR-SERVICE_DOC_ITEM_ID sy-vline
WA_FOTTDCL_POST_MOS_STR-FIPOS sy-vline
WA_FOTTDCL_POST_MOS_STR-FISTL sy-vline
WA_FOTTDCL_POST_MOS_STR-GEBER sy-vline
WA_FOTTDCL_POST_MOS_STR-BUDGET_PD sy-vline
WA_FOTTDCL_POST_MOS_STR-PGEBER sy-vline
WA_FOTTDCL_POST_MOS_STR-PBUDGET_PD sy-vline
WA_FOTTDCL_POST_MOS_STR-BDGT_ACCOUNT sy-vline
WA_FOTTDCL_POST_MOS_STR-BDGT_ACCOUNT_COCODE sy-vline
WA_FOTTDCL_POST_MOS_STR-FMCMMTSTR sy-vline
WA_FOTTDCL_POST_MOS_STR-FMFG_OBJ_CL sy-vline
WA_FOTTDCL_POST_MOS_STR-ANLN1 sy-vline
WA_FOTTDCL_POST_MOS_STR-ANLN2 sy-vline
WA_FOTTDCL_POST_MOS_STR-ANBWA sy-vline
WA_FOTTDCL_POST_MOS_STR-BZDAT sy-vline
WA_FOTTDCL_POST_MOS_STR-FKBER sy-vline
WA_FOTTDCL_POST_MOS_STR-DUMMY_INCL_EEW_COBL sy-vline
WA_FOTTDCL_POST_MOS_STR-RE_BUKRS sy-vline
WA_FOTTDCL_POST_MOS_STR-RE_ACCOUNT sy-vline
WA_FOTTDCL_POST_MOS_STR-GRANT_NBR sy-vline
WA_FOTTDCL_POST_MOS_STR-PGRANT_NBR sy-vline
WA_FOTTDCL_POST_MOS_STR-MEASURE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.