ABAP Select data from SAP table FMXPP_STD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMXPP_STD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMXPP_STD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMXPP_STD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMXPP_STD TYPE STANDARD TABLE OF FMXPP_STD,
      WA_FMXPP_STD TYPE FMXPP_STD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMXPP_STD> TYPE FMXPP_STD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMXPP_STD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMXPP_STD
  INTO TABLE IT_FMXPP_STD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMXPP_STD
*  INTO TABLE @DATA(IT_FMXPP_STD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMXPP_STD INDEX 1 INTO DATA(WA_FMXPP_STD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMXPP_STD ASSIGNING <FMXPP_STD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMXPP_STD>-FIPEX = 1.
<FMXPP_STD>-KATEG = 1.
<FMXPP_STD>-FIVOR = 1.
<FMXPP_STD>-POTYP = 1.
<FMXPP_STD>-FPART = 1.
ENDLOOP.

LOOP AT IT_FMXPP_STD INTO WA_FMXPP_STD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMXPP_STD-FIPUP, sy-vline,
WA_FMXPP_STD-BEZEI, sy-vline,
WA_FMXPP_STD-TEXT1, sy-vline,
WA_FMXPP_STD-TEXT2, sy-vline,
WA_FMXPP_STD-TEXT3, sy-vline,
ENDLOOP. *Add any further fields from structure WA_FMXPP_STD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMXPP_STD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMXPP_STD INTO WA_FMXPP_STD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit FMCIL, internal->external for field FIPEX CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_FMXPP_STD-FIPEX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMXPP_STD-FIPEX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIL, internal->external for field FIPUP CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_FMXPP_STD-FIPUP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMXPP_STD-FIPUP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMXPP_STD_STR,
FIPEX TYPE STRING,
KATEG TYPE STRING,
FIVOR TYPE STRING,
POTYP TYPE STRING,
FPART TYPE STRING,
FIPUP TYPE STRING,
BEZEI TYPE STRING,
TEXT1 TYPE STRING,
TEXT2 TYPE STRING,
TEXT3 TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMXPP_STD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMXPP_STD_STR-FIPEX sy-vline
WA_FMXPP_STD_STR-KATEG sy-vline
WA_FMXPP_STD_STR-FIVOR sy-vline
WA_FMXPP_STD_STR-POTYP sy-vline
WA_FMXPP_STD_STR-FPART sy-vline
WA_FMXPP_STD_STR-FIPUP sy-vline
WA_FMXPP_STD_STR-BEZEI sy-vline
WA_FMXPP_STD_STR-TEXT1 sy-vline
WA_FMXPP_STD_STR-TEXT2 sy-vline
WA_FMXPP_STD_STR-TEXT3 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.