ABAP Select data from SAP table FMSP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMSP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMSP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMSP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMSP TYPE STANDARD TABLE OF FMSP,
      WA_FMSP TYPE FMSP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMSP> TYPE FMSP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMSP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMSP
  INTO TABLE IT_FMSP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMSP
*  INTO TABLE @DATA(IT_FMSP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMSP INDEX 1 INTO DATA(WA_FMSP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMSP ASSIGNING <FMSP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMSP>-MANDT = 1.
<FMSP>-LEDNR = 1.
<FMSP>-OBJNR = 1.
<FMSP>-GJAHR = 1.
<FMSP>-PERBL = 1.
ENDLOOP.

LOOP AT IT_FMSP INTO WA_FMSP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMSP-GEBER, sy-vline,
WA_FMSP-WRTTP, sy-vline,
WA_FMSP-TRGKZ, sy-vline,
WA_FMSP-VORGA, sy-vline,
WA_FMSP-POSIT, sy-vline,
WA_FMSP-TWAER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMSP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMSP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMSP INTO WA_FMSP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field LEDNR CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_FMSP-LEDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSP-LEDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMSP-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSP-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WRTTP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMSP-WRTTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSP-WRTTP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMSP_STR,
MANDT TYPE STRING,
LEDNR TYPE STRING,
OBJNR TYPE STRING,
GJAHR TYPE STRING,
PERBL TYPE STRING,
GEBER TYPE STRING,
WRTTP TYPE STRING,
TRGKZ TYPE STRING,
VORGA TYPE STRING,
POSIT TYPE STRING,
TWAER TYPE STRING,
BUKRS TYPE STRING,
GSBER TYPE STRING,
OBJNRZ TYPE STRING,
BTR001 TYPE STRING,
BTR002 TYPE STRING,
BTR003 TYPE STRING,
BTR004 TYPE STRING,
BTR005 TYPE STRING,
BTR006 TYPE STRING,
BTR007 TYPE STRING,
BTR008 TYPE STRING,
BTR009 TYPE STRING,
BTR010 TYPE STRING,
BTR011 TYPE STRING,
BTR012 TYPE STRING,
BTR013 TYPE STRING,
BTR014 TYPE STRING,
BTR015 TYPE STRING,
BTR016 TYPE STRING,
BTRT01 TYPE STRING,
BTRT02 TYPE STRING,
BTRT03 TYPE STRING,
BTRT04 TYPE STRING,
BTRT05 TYPE STRING,
BTRT06 TYPE STRING,
BTRT07 TYPE STRING,
BTRT08 TYPE STRING,
BTRT09 TYPE STRING,
BTRT10 TYPE STRING,
BTRT11 TYPE STRING,
BTRT12 TYPE STRING,
BTRT13 TYPE STRING,
BTRT14 TYPE STRING,
BTRT15 TYPE STRING,
BTRT16 TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMSP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMSP_STR-MANDT sy-vline
WA_FMSP_STR-LEDNR sy-vline
WA_FMSP_STR-OBJNR sy-vline
WA_FMSP_STR-GJAHR sy-vline
WA_FMSP_STR-PERBL sy-vline
WA_FMSP_STR-GEBER sy-vline
WA_FMSP_STR-WRTTP sy-vline
WA_FMSP_STR-TRGKZ sy-vline
WA_FMSP_STR-VORGA sy-vline
WA_FMSP_STR-POSIT sy-vline
WA_FMSP_STR-TWAER sy-vline
WA_FMSP_STR-BUKRS sy-vline
WA_FMSP_STR-GSBER sy-vline
WA_FMSP_STR-OBJNRZ sy-vline
WA_FMSP_STR-BTR001 sy-vline
WA_FMSP_STR-BTR002 sy-vline
WA_FMSP_STR-BTR003 sy-vline
WA_FMSP_STR-BTR004 sy-vline
WA_FMSP_STR-BTR005 sy-vline
WA_FMSP_STR-BTR006 sy-vline
WA_FMSP_STR-BTR007 sy-vline
WA_FMSP_STR-BTR008 sy-vline
WA_FMSP_STR-BTR009 sy-vline
WA_FMSP_STR-BTR010 sy-vline
WA_FMSP_STR-BTR011 sy-vline
WA_FMSP_STR-BTR012 sy-vline
WA_FMSP_STR-BTR013 sy-vline
WA_FMSP_STR-BTR014 sy-vline
WA_FMSP_STR-BTR015 sy-vline
WA_FMSP_STR-BTR016 sy-vline
WA_FMSP_STR-BTRT01 sy-vline
WA_FMSP_STR-BTRT02 sy-vline
WA_FMSP_STR-BTRT03 sy-vline
WA_FMSP_STR-BTRT04 sy-vline
WA_FMSP_STR-BTRT05 sy-vline
WA_FMSP_STR-BTRT06 sy-vline
WA_FMSP_STR-BTRT07 sy-vline
WA_FMSP_STR-BTRT08 sy-vline
WA_FMSP_STR-BTRT09 sy-vline
WA_FMSP_STR-BTRT10 sy-vline
WA_FMSP_STR-BTRT11 sy-vline
WA_FMSP_STR-BTRT12 sy-vline
WA_FMSP_STR-BTRT13 sy-vline
WA_FMSP_STR-BTRT14 sy-vline
WA_FMSP_STR-BTRT15 sy-vline
WA_FMSP_STR-BTRT16 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.