ABAP Select data from SAP table FMSHD300 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMSHD300 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMSHD300. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMSHD300 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMSHD300 TYPE STANDARD TABLE OF FMSHD300,
      WA_FMSHD300 TYPE FMSHD300,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMSHD300> TYPE FMSHD300.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMSHD300.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMSHD300
  INTO TABLE IT_FMSHD300.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMSHD300
*  INTO TABLE @DATA(IT_FMSHD3002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMSHD300 INDEX 1 INTO DATA(WA_FMSHD3002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMSHD300 ASSIGNING <FMSHD300>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMSHD300>-MANDT = 1.
<FMSHD300>-STATUS = 1.
<FMSHD300>-KGRUND = 1.
<FMSHD300>-KUKEY = 1.
<FMSHD300>-ESNUM = 1.
ENDLOOP.

LOOP AT IT_FMSHD300 INTO WA_FMSHD300.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMSHD300-BUKRS, sy-vline,
WA_FMSHD300-KUNNR, sy-vline,
WA_FMSHD300-KGRUNDTEXT, sy-vline,
WA_FMSHD300-BELNR, sy-vline,
WA_FMSHD300-GJAHR, sy-vline,
WA_FMSHD300-BUZEI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMSHD300 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMSHD300 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMSHD300 INTO WA_FMSHD300. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMSHD300-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSHD300-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMSHD300-BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSHD300-BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMSHD300-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSHD300-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEQ_BELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMSHD300-SEQ_BELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSHD300-SEQ_BELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field SEQ_GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMSHD300-SEQ_GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMSHD300-SEQ_GJAHR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMSHD300_STR,
MANDT TYPE STRING,
STATUS TYPE STRING,
KGRUND TYPE STRING,
KUKEY TYPE STRING,
ESNUM TYPE STRING,
BUKRS TYPE STRING,
KUNNR TYPE STRING,
KGRUNDTEXT TYPE STRING,
BELNR TYPE STRING,
GJAHR TYPE STRING,
BUZEI TYPE STRING,
ACTUSER TYPE STRING,
BLART TYPE STRING,
BLDAT TYPE STRING,
BUDAT TYPE STRING,
DMBTR TYPE STRING,
HWAER TYPE STRING,
SHKZG TYPE STRING,
AZNUM TYPE STRING,
AZDAT TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,
PARTN TYPE STRING,
PAKTO TYPE STRING,
PABLZ TYPE STRING,
XBLNR TYPE STRING,
ZUONR TYPE STRING,
LASTCHANGER TYPE STRING,
RESUBMITDT TYPE STRING,
LONGTEXTICON TYPE STRING,
LONGTEXTEXIST TYPE STRING,
CLEARVZ1 TYPE STRING,
CLEARVZ2 TYPE STRING,
CLEARVZ3 TYPE STRING,
CLEARVZ4 TYPE STRING,
CLEARVZ5 TYPE STRING,
HAUSBANK TYPE STRING,
HAUSBLZ TYPE STRING,
HAUSKONTO TYPE STRING,
ROW_ID TYPE STRING,
SEQ_BUKRS TYPE STRING,
SEQ_BELNR TYPE STRING,
SEQ_GJAHR TYPE STRING,
KURZTEXT TYPE STRING,
FLAG_READONLY TYPE STRING,
FLAG_AUTH_ADMIN TYPE STRING,
FLAG_AUTH_CHANGE TYPE STRING,
FLAG_AUTH_POST TYPE STRING,
FLAG_DIRTY TYPE STRING,
LONGTEXTGUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMSHD300_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMSHD300_STR-MANDT sy-vline
WA_FMSHD300_STR-STATUS sy-vline
WA_FMSHD300_STR-KGRUND sy-vline
WA_FMSHD300_STR-KUKEY sy-vline
WA_FMSHD300_STR-ESNUM sy-vline
WA_FMSHD300_STR-BUKRS sy-vline
WA_FMSHD300_STR-KUNNR sy-vline
WA_FMSHD300_STR-KGRUNDTEXT sy-vline
WA_FMSHD300_STR-BELNR sy-vline
WA_FMSHD300_STR-GJAHR sy-vline
WA_FMSHD300_STR-BUZEI sy-vline
WA_FMSHD300_STR-ACTUSER sy-vline
WA_FMSHD300_STR-BLART sy-vline
WA_FMSHD300_STR-BLDAT sy-vline
WA_FMSHD300_STR-BUDAT sy-vline
WA_FMSHD300_STR-DMBTR sy-vline
WA_FMSHD300_STR-HWAER sy-vline
WA_FMSHD300_STR-SHKZG sy-vline
WA_FMSHD300_STR-AZNUM sy-vline
WA_FMSHD300_STR-AZDAT sy-vline
WA_FMSHD300_STR-HBKID sy-vline
WA_FMSHD300_STR-HKTID sy-vline
WA_FMSHD300_STR-PARTN sy-vline
WA_FMSHD300_STR-PAKTO sy-vline
WA_FMSHD300_STR-PABLZ sy-vline
WA_FMSHD300_STR-XBLNR sy-vline
WA_FMSHD300_STR-ZUONR sy-vline
WA_FMSHD300_STR-LASTCHANGER sy-vline
WA_FMSHD300_STR-RESUBMITDT sy-vline
WA_FMSHD300_STR-LONGTEXTICON sy-vline
WA_FMSHD300_STR-LONGTEXTEXIST sy-vline
WA_FMSHD300_STR-CLEARVZ1 sy-vline
WA_FMSHD300_STR-CLEARVZ2 sy-vline
WA_FMSHD300_STR-CLEARVZ3 sy-vline
WA_FMSHD300_STR-CLEARVZ4 sy-vline
WA_FMSHD300_STR-CLEARVZ5 sy-vline
WA_FMSHD300_STR-HAUSBANK sy-vline
WA_FMSHD300_STR-HAUSBLZ sy-vline
WA_FMSHD300_STR-HAUSKONTO sy-vline
WA_FMSHD300_STR-ROW_ID sy-vline
WA_FMSHD300_STR-SEQ_BUKRS sy-vline
WA_FMSHD300_STR-SEQ_BELNR sy-vline
WA_FMSHD300_STR-SEQ_GJAHR sy-vline
WA_FMSHD300_STR-KURZTEXT sy-vline
WA_FMSHD300_STR-FLAG_READONLY sy-vline
WA_FMSHD300_STR-FLAG_AUTH_ADMIN sy-vline
WA_FMSHD300_STR-FLAG_AUTH_CHANGE sy-vline
WA_FMSHD300_STR-FLAG_AUTH_POST sy-vline
WA_FMSHD300_STR-FLAG_DIRTY sy-vline
WA_FMSHD300_STR-LONGTEXTGUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.